• Part No: R302 MLPA DHHS
• S/N: 134E/23699
• Field Size: ~0 × 0 cm to ~48 × 48 cm at 100 cm SID
• Radiation Protection: Up to 150 kVp – 4 mA
• Shutters: 6 pairs multi-layer lead shutters
• Filtration: ≥2 mm Al equivalent
• Date of Manufacturing: 07-2011
Precision Collimation for Diagnostic X-Ray Imaging
The Ralco R302 MLP/A DHHS X-Ray Collimator is a high-quality beam-limiting device designed to provide exceptional control over the X-ray field in fixed diagnostic imaging environments. Engineered with a multilayer square field and six pairs of lead shutters, this collimator enables radiologic technologists to tailor the X-ray beam size with precision, optimizing contrast and reducing unnecessary radiation to surrounding tissues. Adjustable from small to large field sizes (up to ~48 × 48 cm at 100 cm SID), it supports a broad range of protocols including skeletal, thoracic, and general body imaging — improving consistency and image quality across exams.
Reliable Safety and Easy Field Visualization
Safety is at the core of the Ralco R302 design, with engineered radiation protection up to 150 kVp and 4 mA and a minimum inherent filtration of 2 mm Al equivalent to help control beam quality without compromising performance. An integrated light field and adjustable mirror system give clinicians accurate visual alignment of the imaging field prior to exposure, reducing repeat scans and patient dose. Built to withstand the rigors of routine clinical use, this collimator maintains dependable functionality even in high-volume radiography suites.
Ideal OEM Replacement for System Maintenance
Perfect for service engineers, imaging facilities, and biomedical teams, the Ralco R302 MLP/A DHHS X-Ray Collimator (DOM: 07-2011) is a trusted OEM component to support continued operation of legacy and stationary X-ray systems. Whether restoring a system to original performance or upgrading imaging accessories, this collimator’s robust construction and precise beam-limiting capabilities help preserve diagnostic accuracy and operational efficiency. With decades of Ralco expertise in collimation solutions, it’s a smart choice for facilities focused on maintaining superior imaging standards.
This medical equipment item is a subcomponent or part that has been extracted from a larger system or unit. It is intended for use as a replacement part or for integration into another system. Its condition may vary, but it has been removed with care to preserve its functionality.