{"product_id":"cooper-surgical-52969-leep-system-1000-w-smoke-evac-footswitch","title":"Cooper Surgical 52969 LEEP System 1000 w\/ Smoke Evac \u0026 Footswitch","description":"\u003ch4 data-path-to-node=\"2\"\u003eCooperSurgical LEEP System 1000 | Integrated Smoke Evacuation | 52969\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eCooperSurgical 52969\u003c\/b\u003e is a comprehensive electrosurgical workstation designed specifically for Loop Electrosurgical Excision Procedures (LEEP). This all-in-one console integrates a high-frequency electrosurgical generator with a dedicated smoke evacuation system, providing a streamlined footprint for the modern colposcopy suite or outpatient procedure room.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eBy combining cutting\/coagulation controls with high-flow smoke evacuation in a single unit, the System 1000 ensures that the surgical field remains clear of plume and odor, meeting 2026 OSHA and AORN safety standards for surgical smoke management.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e CooperSurgical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eSeries:\u003c\/b\u003e LEEP System 1000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 52969\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eOutput Frequency:\u003c\/b\u003e High-frequency, constant voltage for minimized thermal spread\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eIntegrated Features:\u003c\/b\u003e Electrosurgical Generator + Smoke Evacuator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eControl Interface:\u003c\/b\u003e Front-panel power dials and evacuation flow adjustment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eActivation:\u003c\/b\u003e Included pneumatic footswitch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eOptimized Waveform Control:\u003c\/b\u003e The System 1000 is engineered to provide a smooth, consistent cut. This is critical for obtaining high-quality histological specimens with minimal \"char\" or thermal artifact at the margins, facilitating more accurate pathology reports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eSynchronized Smoke Evacuation:\u003c\/b\u003e The integrated vacuum system is designed to remove the surgical plume at the point of origin. This protects the clinical team from potentially hazardous biological aerosols and ensures an unobstructed view of the cervix during the procedure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eStreamlined Procedural Footprint:\u003c\/b\u003e Instead of managing two separate machines, the 52969 console consolidates the workflow. The footswitch allows for hands-free activation of both the generator and the suction, allowing the clinician to focus entirely on the colposcopic view.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eBroad Accessory Ecosystem:\u003c\/b\u003e This system is compatible with a wide range of CooperSurgical LEEP electrodes (loops, balls, and squares) and uses industry-standard 3-prong handpieces and split\/solid return pads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eSystem Components \u0026amp; Accessories\u003c\/h4\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe \u003cb data-path-to-node=\"10\" data-index-in-node=\"4\"\u003e52969 LEEP System 1000\u003c\/b\u003e serves as the hub for the following essential components:\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eSmoke Evacuation Filters:\u003c\/b\u003e High-efficiency ULPA filters to trap 99.999% of plume particles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eDisposable Tubing \u0026amp; Adapters:\u003c\/b\u003e Specialized tubing that attaches to vaginal speculums for passive or active smoke capture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003ePneumatic Footswitch:\u003c\/b\u003e For safe, explosion-proof activation in the presence of various medical gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eHandpiece \u0026amp; Patient Return Pad:\u003c\/b\u003e Standardized interfaces for electrosurgical safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eCervical Dysplasia Treatment:\u003c\/b\u003e Performing LEEP for the removal of CIN II\/III and other high-grade lesions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eDiagnostic Excisions:\u003c\/b\u003e Obtaining \"Large Loop\" specimens for histopathology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eGeneral Electrosurgery:\u003c\/b\u003e Suitable for minor dermatological or gynecological cautery where smoke management is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"8\"\u003eUSED — Very Good Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eCosmetic Note:\u003c\/b\u003e This unit shows minor cosmetic wear consistent with previous clinical use in a professional environment. All labels and control markings remain legible and intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eBiomedical Clearance:\u003c\/b\u003e It is highly recommended that this unit be inspected and \"safety-checked\" by a certified Biomedical Equipment Technician (BMET) prior to clinical use to ensure output calibrations and grounding leakage are within manufacturer specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eConsumable Note:\u003c\/b\u003e This listing includes the console and footswitch. Smoke evacuation filters, speculum tubing, handpieces, and electrodes are sold separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"16\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003e\u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in heavy-duty, protective packaging to ensure the internal generator components and vacuum motor are protected from shock during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003e\u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1-2 business days.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay-1_c6109824-9dd5-4bb7-9f79-c15f2e0079f9.png?v=1775673686\" alt=\"\"\u003e\u003c\/p\u003e","brand":"CooperSurgical","offers":[{"title":"Default Title","offer_id":48192830701793,"sku":"COOP52969","price":595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay-1_64c7685a-04d1-4c07-933f-0cf27f3c6638.png?v=1775673655","url":"https:\/\/primismedical.com\/en-cn\/products\/cooper-surgical-52969-leep-system-1000-w-smoke-evac-footswitch","provider":"Primis Medical","version":"1.0","type":"link"}