{"product_id":"cox-ii-ocular-laser-shields-m-l-stainless-steel-ophthalmic-lot-of-4","title":"Cox II Ocular Laser Shields M\/L Stainless Steel Ophthalmic Lot of 4","description":"\u003ch4 data-path-to-node=\"2\"\u003eCox II Ocular Laser Shields | Stainless Steel | Lot of 4\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eCox II Ocular Laser Shield\u003c\/b\u003e is the global gold standard for internal ocular protection during laser, IPL (Intense Pulsed Light), and periocular surgical procedures. Unlike external patches, these stainless steel shields are designed for \u003cb data-path-to-node=\"3\" data-index-in-node=\"240\"\u003edirect placement on the globe\u003c\/b\u003e, providing a total barrier against laser energy. This allows the practitioner to treat the eyelids and the surrounding periorbital area with maximum safety and precision.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eConstructed from surgical-grade stainless steel, these shields feature a \u003cb data-path-to-node=\"4\" data-index-in-node=\"73\"\u003enon-reflective (matte) outer surface\u003c\/b\u003e to prevent hazardous beam reflection and a \u003cb data-path-to-node=\"4\" data-index-in-node=\"153\"\u003ehighly polished posterior surface\u003c\/b\u003e to ensure patient comfort and prevent corneal epithelial trauma.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eFull Spectrum Protection:\u003c\/b\u003e Provides an opaque barrier against a wide range of wavelengths, including CO2, Erbium, Nd:YAG, and IPL.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eVaulted Design:\u003c\/b\u003e The Cox II style is specifically vaulted to prevent contact with the corneal apex, resting instead on the sclera to minimize the risk of corneal abrasion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eMatte Exterior Finish:\u003c\/b\u003e Engineered to diffuse laser light, preventing accidental reflected beams that could injure the practitioner or damage surrounding tissue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003ePolished Interior:\u003c\/b\u003e The posterior side is polished to a mirror finish, ensuring smooth contact when used with a sterile ophthalmic lubricant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eIntegrated Safety Tab:\u003c\/b\u003e Each shield features a small flared handle\/tab at the superior edge, facilitating easy insertion and removal with a suction cup or forceps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eLot Contents \u0026amp; Sizing\u003c\/h4\u003e\n\u003cp data-path-to-node=\"8\"\u003eThis lot of four shields is curated to accommodate a broad patient demographic:\u003c\/p\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003e2x Medium (M):\u003c\/b\u003e Approx. \u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"23\"\u003e25.5 mm x 22.0 mm\u003c\/b\u003e (Standard adult size)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003e2x Large (L):\u003c\/b\u003e Approx. \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"22\"\u003e26.5 mm x 23.0 mm\u003c\/b\u003e (Suited for larger globes\/male patients)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"10\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Medical-grade Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eStyle:\u003c\/b\u003e Cox II (Internal Ocular)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eWavelength Compatibility:\u003c\/b\u003e All medical lasers and IPL systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eAutoclavable:\u003c\/b\u003e Yes (Unlimited cycles)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eFormat:\u003c\/b\u003e Reusable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eSuperior Periocular Access:\u003c\/b\u003e Because the shield is placed under the eyelids, clinicians can treat the entire eyelid margin and \"crow's feet\" area without the obstruction caused by bulky external goggles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eUnmatched Safety:\u003c\/b\u003e Provides a level of protection that plastic or disposable shields cannot match, particularly during high-wattage CO2 or Erbium resurfacing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eHigh ROI:\u003c\/b\u003e Being fully autoclavable and durable, these shields eliminate the recurring cost of disposables, offering a lower total cost of ownership for high-volume laser clinics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eDermatology \u0026amp; Medical Aesthetics:\u003c\/b\u003e Laser blepharoplasty, periocular skin resurfacing, and IPL hair removal\/vascular treatments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eOphthalmology:\u003c\/b\u003e Protection during specialized eyelid surgeries or periorbital laser therapy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003ePlastic Surgery:\u003c\/b\u003e Full-face laser peels where ocular protection is mission-critical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"16\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003e\u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"8\"\u003eUsed — Excellent Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003e\u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"0\"\u003eIntegrity:\u003c\/b\u003e The polished posterior surfaces have been inspected and are free of pits, deep scratches, or burrs that could irritate the cornea.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003e\u003cb data-path-to-node=\"17,2,0\" data-index-in-node=\"0\"\u003eMaintenance:\u003c\/b\u003e Well-maintained and structurally sound; no warping or deformation at the edges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003e\u003cb data-path-to-node=\"17,3,0\" data-index-in-node=\"0\"\u003eReprocessing Note:\u003c\/b\u003e These shields are provided non-sterile. They \u003cb data-path-to-node=\"17,3,0\" data-index-in-node=\"64\"\u003emust\u003c\/b\u003e be cleaned and undergo a validated steam autoclave cycle before clinical use. The use of a topical anesthetic and ophthalmic ointment (e.g., Lacri-Lube) is required for patient comfort during insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cox II","offers":[{"title":"Default Title","offer_id":48360028635361,"sku":"COXII4LOT4","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/primis-auctions-dotmed-1_a31c5e3b-ac52-491a-a682-ae5e9fef4bf0.png?v=1778539109","url":"https:\/\/primismedical.com\/en-cn\/products\/cox-ii-ocular-laser-shields-m-l-stainless-steel-ophthalmic-lot-of-4","provider":"Primis Medical","version":"1.0","type":"link"}