{"product_id":"dorc-1286-wd06-eckardt-end-gripping-forceps-23-gauge-0-6mm-disposable-vitreoretinal-instrument","title":"DORC 1286.WD06 Eckardt End-Gripping Forceps - 23 Gauge (0.6mm), Disposable Vitreoretinal Instrument","description":"\u003ch4 data-path-to-node=\"2\"\u003eDORC Eckardt End-Gripping Forceps | 23G \/ 0.6 mm | 1286.WD06\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eDORC 1286.WD06\u003c\/b\u003e is a high-precision vitreoretinal instrument engineered for 2026 standards in macular surgery. Developed in collaboration with Prof. Claus Eckardt, these forceps are considered a primary standard for \u003cb data-path-to-node=\"3\" data-index-in-node=\"219\"\u003eInternal Limiting Membrane (ILM) peeling\u003c\/b\u003e and the removal of delicate epiretinal membranes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eFeaturing a \u003cb data-path-to-node=\"4\" data-index-in-node=\"12\"\u003e23-gauge (0.6 mm)\u003c\/b\u003e profile, this instrument bridges the gap between the rigidity of 20G and the extreme flexibility of 25G\/27G, providing the structural stability needed for peripheral maneuvers while remaining compatible with standard 23G transconjunctival trocar systems.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eStationary Distal Tip Closure:\u003c\/b\u003e Unlike traditional forceps where both jaws move, the 1286.WD06 utilizes a stationary distal tip mechanism. This eliminates \"tip-jump\" during closure, ensuring the membrane is grasped exactly where the surgeon intends—crucial for preventing iatrogenic retinal trauma.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eEckardt \"Nail-Style\" Platforms:\u003c\/b\u003e The tips are designed with specialized end-gripping platforms that mimic a fine \"nail\" shape. This provides a focused, high-pressure grasping surface that excels at catching the edge of transparent membranes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eSynchronous Actuation:\u003c\/b\u003e The DORC Advantage handpiece provides a smooth, synchronous 360° actuation, offering the surgeon consistent tactile feedback regardless of how the instrument is rotated within the eye.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eAnti-Reflective Finish:\u003c\/b\u003e The shaft and jaws are treated with a matte, non-glare finish to minimize light scatter from the surgical microscope, improving depth perception during micro-dissection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eHigh-Rigidity 23G Shaft:\u003c\/b\u003e The 0.6 mm diameter offers superior torque and resistance to bending compared to smaller gauges, making it ideal for cases involving dense PVR membranes or highly adherent ILM.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e DORC (Dutch Ophthalmic Research Center)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eProduct Code:\u003c\/b\u003e 1286.WD06\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eGauge:\u003c\/b\u003e 23 Gauge (0.6 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eTip Style:\u003c\/b\u003e Eckardt End-Gripping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eHandle Type:\u003c\/b\u003e Advantage Series (Ergonomic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eFormat:\u003c\/b\u003e Single-Use \/ Disposable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eQuantity:\u003c\/b\u003e Box of 5 Units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003ePrecision Initiation:\u003c\/b\u003e The end-gripping geometry is specifically optimized for \"picking up\" the edge of the ILM without the need for additional picks or scrapers, streamlining the surgical workflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eEnhanced Safety:\u003c\/b\u003e By utilizing a stationary tip, the risk of \"pinching\" the underlying retina during the initiation of a peel is significantly reduced.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eStandardized Outpatient Logistics:\u003c\/b\u003e Sourcing genuine DORC overstock allows facilities to provide world-class, designer-series instrumentation in a sterile, single-use format, eliminating the high costs of repair and micro-alignment required for reusable alternatives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eILM Peeling:\u003c\/b\u003e Macular hole repair and Macular Pucker (ERM) management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003ePVR Management:\u003c\/b\u003e Delamination of proliferative vitreoretinal membranes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eMIVS Procedures:\u003c\/b\u003e 23-gauge sutureless vitrectomy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"8\"\u003eNEW — Genuine DORC Overstock.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003ePackaging:\u003c\/b\u003e Original OEM box containing 5 individually sterile-wrapped instruments. All factory seals are 100% intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eStorage:\u003c\/b\u003e Maintained in a climate-controlled, medical-grade environment to ensure the micro-alignment of the jaws remains factory-perfect.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DORC","offers":[{"title":"Default Title","offer_id":48293173428449,"sku":null,"price":74.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/ProductPhotos-2026-05-06T101142.130.png?v=1778084022","url":"https:\/\/primismedical.com\/en-cn\/products\/dorc-1286-wd06-eckardt-end-gripping-forceps-23-gauge-0-6mm-disposable-vitreoretinal-instrument","provider":"Primis Medical","version":"1.0","type":"link"}