{"product_id":"gsource-gs83-8880-gpin-cutter-da-9-angled-side-tc-2-8mm-max","title":"gSource GS83.8880 gPin Cutter DA 9\" Angled Side TC 2.8mm Max","description":"\u003ch4 data-path-to-node=\"2\"\u003egSource® Double-Action gPin Cutter | Angled Side-Cut | GS83.8880\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003egSource GS83.8880\u003c\/b\u003e is a high-performance orthopedic instrument engineered for the 2026 standards of skeletal fixation and trauma management. Designed with a \u003cb data-path-to-node=\"3\" data-index-in-node=\"160\"\u003eDouble-Action (DA)\u003c\/b\u003e hinge mechanism, this cutter provides significantly enhanced leverage, allowing the user to shear through surgical pins with roughly half the hand force required by single-action tools.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe specialized \u003cb data-path-to-node=\"4\" data-index-in-node=\"16\"\u003eangled side-cutting\u003c\/b\u003e orientation is critical for procedures where pins must be cut flush to the bone or within deep, restricted surgical corridors where a standard front-cutting tool cannot reach.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eDouble-Action Leverage:\u003c\/b\u003e The dual-pivot design multiplies manual input, ensuring a smooth, controlled cut and reducing the \"shock\" to the patient's bone and the surgeon's hand upon pin fracture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eTungsten Carbide (TC) Inserts:\u003c\/b\u003e Identified by the signature gold-plated handles, these jaws feature ultra-hard tungsten carbide inserts. This ensures the cutting edges remain sharp through repeated use on hardened stainless steel and titanium alloys.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eAngled Side-Cutting Geometry:\u003c\/b\u003e The jaws are offset to the side, allowing for \"flush\" cutting of pins and wires near the skin or bone surface without the handles obstructing the view or the physical path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003e2.8 mm (7\/64\") Capacity:\u003c\/b\u003e Specifically calibrated for pins up to 2.8 mm. This makes it the ideal tool for standard Kirschner wires (K-wires) and smaller Steinmann pins used in hand, foot, and pediatric orthopedic procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eSurgical-Grade Craftsmanship:\u003c\/b\u003e Forged from high-vacuum melted stainless steel, providing superior corrosion resistance and structural integrity during high-temperature sterilization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e gSource\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eModel\/REF:\u003c\/b\u003e GS83.8880\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eAction:\u003c\/b\u003e Double-Action (DA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eJaw Type:\u003c\/b\u003e Angled Side-Cutting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eInserts:\u003c\/b\u003e Tungsten Carbide (TC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eOverall Length:\u003c\/b\u003e 9\" (22.9 cm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eMaximum Capacity:\u003c\/b\u003e 2.8 mm (7\/64\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,7,0\"\u003e\u003cb data-path-to-node=\"8,7,0\" data-index-in-node=\"0\"\u003eSterilization:\u003c\/b\u003e Fully Autoclavable (Reusable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eEnhanced Access:\u003c\/b\u003e The angled head is a strategic advantage for surgeons working in tight anatomical spaces, such as the ankle, wrist, or during pediatric fracture fixation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eReduced Replacement Costs:\u003c\/b\u003e Tungsten carbide is significantly more durable than standard stainless steel; these cutters require less frequent sharpening and have a substantially longer clinical lifespan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eErgonomic Safety:\u003c\/b\u003e The double-action mechanism minimizes the risk of repetitive strain for the surgical team, especially during high-volume trauma rotations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eStrategic Procurement:\u003c\/b\u003e Acquiring this \"Excellent Condition\" gSource cutter allows a facility to provide top-tier orthopedic instrumentation while optimizing its capital budget for surgical disposables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eOrthopedic Trauma:\u003c\/b\u003e Cutting K-wires and small pins during fracture stabilization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003ePodiatric \u0026amp; Hand Surgery:\u003c\/b\u003e Precise, flush-cutting of fixation hardware in small-joint procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003ePediatric Orthopedics:\u003c\/b\u003e Managing smaller gauge hardware where precision and low-vibration cutting are required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eHardware Removal:\u003c\/b\u003e Extracting or shortening existing orthopedic wires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"8\"\u003eUsed — Excellent Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eMechanical Integrity:\u003c\/b\u003e The double-action pivot is smooth and tight. The TC jaws have been inspected and are free of chips, cracks, or misalignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eSurface Condition:\u003c\/b\u003e The gold handle plating is intact, and all laser-etched manufacturer markings are crisp and legible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eMaintenance Note:\u003c\/b\u003e As a double-action instrument, this cutter should be cleaned in the \"open\" position to ensure the secondary pivot points are decontaminated. Regular application of surgical-grade lubricant (instrument milk) is essential for maintaining the leverage mechanics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GSOURCE LLC","offers":[{"title":"Default Title","offer_id":48369401790689,"sku":"GSOUGS83.8880","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/primis-auctions-dotmed-1_1630e943-3333-4b0d-9426-c3c5eac7e66b.png?v=1778782998","url":"https:\/\/primismedical.com\/en-cn\/products\/gsource-gs83-8880-gpin-cutter-da-9-angled-side-tc-2-8mm-max","provider":"Primis Medical","version":"1.0","type":"link"}