{"product_id":"jpi-jw50207661-x-ray-imaging-anti-scatter-grid-12-1-36-l-cm-tube-side","title":"JPI JW50207661 X-Ray Imaging Anti-Scatter Grid 12:1 36 L\/cm Tube Side","description":"\u003ch4 data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eJPI JW50207661 12:1 \/ 36 L\/cm 100cm Fixed-Focus Anti-Scatter Grid\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"8\"\u003eThe \u003cb data-path-to-node=\"8\" data-index-in-node=\"4\"\u003eJPI JW50207661\u003c\/b\u003e is a professional imaging accessory designed to deliver superior diagnostic clarity by filtering out non-directional scattered photons. Optimized for a \u003cb data-path-to-node=\"8\" data-index-in-node=\"171\"\u003e1-meter (40-inch) focal distance\u003c\/b\u003e, this grid is perfectly calibrated for standard Bucky and upright chest radiography. The \u003cb data-path-to-node=\"8\" data-index-in-node=\"293\"\u003e12:1 grid ratio\u003c\/b\u003e provides high-efficiency scatter rejection, making it the preferred choice for abdominal, pelvic, and lateral spine imaging where scattered radiation is most prevalent.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eConstructed with a \u003cb data-path-to-node=\"9\" data-index-in-node=\"19\"\u003ecarbon fiber exterior\u003c\/b\u003e, this grid minimizes \"grid factor\" radiation absorption, allowing for high-contrast images while maintaining dose efficiency. The clearly marked \u003cb data-path-to-node=\"9\" data-index-in-node=\"186\"\u003e\"Tube Side\"\u003c\/b\u003e ensures correct orientation to prevent grid cut-off, while the 438 × 479.5 mm dimensions provide universal compatibility with most standard 14x17\" and 17x17\" detector systems and Bucky trays.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eKey Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e JPI Healthcare\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eModel Number:\u003c\/b\u003e JW50207661\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eGrid Ratio:\u003c\/b\u003e 12:1 (High-contrast scatter cleanup)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eLine Frequency:\u003c\/b\u003e 36 lines\/cm (Optimized for digital and film imaging)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eFocal Distance:\u003c\/b\u003e 1.0 m (100 cm \/ Approx. 39.4 inches)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eSurface Material:\u003c\/b\u003e Carbon Fiber (Low attenuation, high durability)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-path-to-node=\"11,6,0\" data-index-in-node=\"0\"\u003eInterspacer:\u003c\/b\u003e Aluminum (Rigid internal alignment)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\"\u003e\u003cb data-path-to-node=\"11,7,0\" data-index-in-node=\"0\"\u003eDimensions:\u003c\/b\u003e Approx. 438 × 479.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eClinical \u0026amp; Technical Advantages\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eSuperior Scatter Cleanup:\u003c\/b\u003e The 12:1 ratio is significantly more effective than 8:1 or 10:1 grids at removing secondary radiation, resulting in \"blacker\" blacks and sharper anatomical borders.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eStandardized Focal Alignment:\u003c\/b\u003e Calibrated for the most common SID (Source-to-Image Distance) in general radiography, ensuring edge-to-edge brightness without peripheral cut-off.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003ePremium Carbon Fiber Finish:\u003c\/b\u003e Unlike older plastic-surfaced grids, the carbon fiber face is highly resistant to scratches and cleaning agents, ensuring a long clinical lifespan in high-volume environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eLightweight \u0026amp; Rigid:\u003c\/b\u003e The aluminum interspacer prevents internal lead-strip warping, a common cause of artifacts in mobile imaging environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eCondition\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"8\"\u003eUsed – Good Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eFunctional Assessment:\u003c\/b\u003e Grid is physically flat and structurally sound. Lead strips are aligned with no visible evidence of drop damage or internal kinking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eCosmetic Status:\u003c\/b\u003e Shows minor signs of professional use, such as light surface scuffs. These are purely cosmetic and do not interfere with the X-ray beam or image quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eVerification:\u003c\/b\u003e This is a passive accessory. It does not contain electronics or generate radiation. Please verify that 438 x 479.5mm fits your specific Bucky or grid cap before purchase.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eWarranty\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003e\u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"0\"\u003e✔ Primis \"Artifact-Free\" Guarantee\u003c\/b\u003e We guarantee the JPI JW50207661 to be free of internal defects or lead-strip misalignment. If the grid produces visible linear artifacts or excessive cut-off at the 100cm focal distance upon arrival, Primis Medical will provide a full refund or replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eWhat’s Included\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,0\"\u003e(1) JPI JW50207661 12:1 \/ 36 L\/cm Anti-Scatter Grid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"20\"\u003e\u003cb data-path-to-node=\"20\" data-index-in-node=\"0\"\u003eShipping\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"21\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,0,0\"\u003e\u003cb data-path-to-node=\"21,0,0\" data-index-in-node=\"0\"\u003eFast and secure shipping.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,1,0\"\u003eShips within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,2,0\"\u003ePackaged in a reinforced, flat-profile shipping container with edge protection to ensure the grid arrives in pristine, ready-to-image condition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"JPI","offers":[{"title":"Default Title","offer_id":48113592697057,"sku":"JPI-JW50207661-U","price":382.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay-6_03e41fa2-d23f-4271-bc65-5228ce822f8a.png?v=1774037393","url":"https:\/\/primismedical.com\/en-cn\/products\/jpi-jw50207661-x-ray-imaging-anti-scatter-grid-12-1-36-l-cm-tube-side","provider":"Primis Medical","version":"1.0","type":"link"}