{"product_id":"jpi-jw90318593-x-ray-imaging-anti-scatter-grid-12-1-36-l-cm-multi-focus","title":"JPI JW90318593 X-Ray Imaging Anti-Scatter Grid 12:1 36 L\/cm Multi Focus","description":"\u003ch4 data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eJPI JW90318593 12:1 \/ 36 L\/cm Multi-Focus Anti-Scatter Grid\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"8\"\u003eThe \u003cb data-path-to-node=\"8\" data-index-in-node=\"4\"\u003eJPI JW90318593\u003c\/b\u003e is a professional-grade radiographic grid designed to maximize image clarity by filtering out non-diagnostic secondary radiation. Constructed with a rigid \u003cb data-path-to-node=\"8\" data-index-in-node=\"174\"\u003ealuminum interspacer\u003c\/b\u003e and a premium \u003cb data-path-to-node=\"8\" data-index-in-node=\"209\"\u003ecarbon fiber surface\u003c\/b\u003e, this grid offers low X-ray absorption (attenuation) of the primary beam while maintaining the structural integrity required for busy imaging departments.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eWith a \u003cb data-path-to-node=\"9\" data-index-in-node=\"7\"\u003e12:1 ratio\u003c\/b\u003e, this grid is optimized for high-energy procedures, providing superior cleanup of scattered photons to ensure \"bone-on-black\" contrast. Its \u003cb data-path-to-node=\"9\" data-index-in-node=\"158\"\u003eMulti-Focus\u003c\/b\u003e capability makes it a \"workhorse\" accessory, as it remains effective across three distinct focal distances, reducing the need for multiple specialized grids in a single X-ray suite.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eKey Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e JPI Healthcare\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eModel Number:\u003c\/b\u003e JW90318593\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eGrid Ratio:\u003c\/b\u003e 12:1 (Superior scatter cleanup)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eFrequency:\u003c\/b\u003e 36 lines\/cm (High resolution)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eFocal Range (Multi-Focus):\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"11,4,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,1,0,0\"\u003e\u003cb data-path-to-node=\"11,4,1,0,0\" data-index-in-node=\"0\"\u003eF0:\u003c\/b\u003e 1.0 m (39.4 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,1,1,0\"\u003e\u003cb data-path-to-node=\"11,4,1,1,0\" data-index-in-node=\"0\"\u003eF1:\u003c\/b\u003e 87.8 cm (34.6 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,1,2,0\"\u003e\u003cb data-path-to-node=\"11,4,1,2,0\" data-index-in-node=\"0\"\u003eF2:\u003c\/b\u003e 116.1 cm (45.7 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eDimensions:\u003c\/b\u003e Approx. 438 × 479.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-path-to-node=\"11,6,0\" data-index-in-node=\"0\"\u003eConstruction:\u003c\/b\u003e Aluminum Interspacer with Carbon Fiber Surface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eClinical \u0026amp; Technical Advantages\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eEnhanced Diagnostic Contrast:\u003c\/b\u003e The 12:1 ratio is ideal for bariatric imaging or lateral lumbar views where scatter is most prevalent, ensuring clear visualization of fine trabecular patterns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eFlexible Focal Distance:\u003c\/b\u003e The F0\/F1\/F2 labeling allows technologist flexibility, ensuring consistent image quality whether performing table-top, Bucky, or upright chest radiography.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eLow Dose Efficiency:\u003c\/b\u003e The carbon fiber surface reduces the \"grid factor\" absorption of the primary beam, allowing for high-quality images with optimized patient dose.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eDurability:\u003c\/b\u003e The carbon fiber exterior provides a scratch-resistant, easy-to-clean surface that withstands the rigors of mobile and stationary X-ray environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eCondition\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"8\"\u003eUsed – Excellent Physical Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eVisual Assessment:\u003c\/b\u003e The grid surface is flat and free of dents, kinks, or significant scratches that could cause artifacts. The labeling is clear and legible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eOperational Note:\u003c\/b\u003e This is a passive standalone accessory. It contains no electronic components. Verification of fit for your specific Bucky or cassette holder is recommended.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eWarranty\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003e\u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"0\"\u003e✔ Primis \"Artifact-Free\" Guarantee\u003c\/b\u003e We guarantee the JPI JW90318593 to be structurally sound and free of internal lead-strip damage. If the grid arrives bent or produces visible linear artifacts upon initial testing, Primis Medical will provide a full refund or replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eWhat’s Included\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,0\"\u003e(1) JPI JW90318593 Multi-Focus Anti-Scatter Grid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"20\"\u003e\u003cb data-path-to-node=\"20\" data-index-in-node=\"0\"\u003eShipping\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"21\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,0,0\"\u003e\u003cb data-path-to-node=\"21,0,0\" data-index-in-node=\"0\"\u003eFast and secure shipping.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,1,0\"\u003eShips within 1-2 business days.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,2,0\"\u003ePackaged in a reinforced, flat-pack container with specialized padding to prevent bending or warping during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"JPI","offers":[{"title":"Default Title","offer_id":48113580245217,"sku":"JPI-JW90318593-U","price":382.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay-5_bb82b511-c2d3-4d7b-b999-46dff98f20dd.png?v=1774036876","url":"https:\/\/primismedical.com\/en-cn\/products\/jpi-jw90318593-x-ray-imaging-anti-scatter-grid-12-1-36-l-cm-multi-focus","provider":"Primis Medical","version":"1.0","type":"link"}