{"product_id":"karl-storz-8401hxp-c-mac-pediatric-d-blade-laryngoscope","title":"Karl Storz 8401HXP C-MAC Pediatric D-Blade Laryngoscope","description":"\u003ch4 data-path-to-node=\"2\"\u003eKarl Storz C-MAC® Pediatric D-Blade | 8401HXP\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eKarl Storz 8401HXP\u003c\/b\u003e is a specialized video laryngoscope blade engineered for the most challenging pediatric airway scenarios. Unlike standard Macintosh or Miller blades, the \u003cb data-path-to-node=\"3\" data-index-in-node=\"177\"\u003eD-Blade\u003c\/b\u003e features a unique, hyperangulated (half-moon) shape designed specifically to \"see around the corner\" in patients with difficult anatomy.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eThis blade is the clinical gold standard for pediatric patients (typically weighing between \u003cb data-path-to-node=\"4\" data-index-in-node=\"92\"\u003e22–55 lbs\u003c\/b\u003e) who present with anatomical disorders such as Down syndrome, Pierre Robin sequence, or Crouzon syndrome. By utilizing advanced \u003cb data-path-to-node=\"4\" data-index-in-node=\"230\"\u003eCMOS technology\u003c\/b\u003e, the 8401HXP provides a high-resolution, wide-angle view of the glottis, even when the oral aperture is restricted or the larynx is positioned highly anteriorly.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eHyperangulated D-Blade Geometry:\u003c\/b\u003e The elliptically tapered, highly curved profile allows for superior glottic visualization in \"can't-see\" scenarios where direct laryngoscopy is impossible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eCMOS Visualization Technology:\u003c\/b\u003e Features an integrated digital sensor at the distal tip that delivers a \u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"103\"\u003e70° to 80° diagonal field of view\u003c\/b\u003e, ensuring the surgeon can identify anatomical landmarks with crystal clarity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003ePediatric-Optimized Dimensions:\u003c\/b\u003e With a working length of \u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"57\"\u003e76 mm\u003c\/b\u003e and a distal width of only \u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"90\"\u003e13 mm\u003c\/b\u003e, this blade is perfectly proportioned for the small oropharyngeal cavity of a child.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eLow-Profile Stainless Steel:\u003c\/b\u003e The thin, robust metal construction minimizes the displacement of soft tissue, providing more room for endotracheal tube passage in limited spaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eHigh-Intensity LED Illumination:\u003c\/b\u003e Dual-LED light sources provide homogenous, cool-white illumination, preventing the shadows or \"fogging\" that can obscure the view during critical airway maneuvers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Karl Storz (Made in Germany)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e 8401HXP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eSeries:\u003c\/b\u003e C-MAC®\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eBlade Type:\u003c\/b\u003e Pediatric D-Blade (Hyperangulated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eWorking Length:\u003c\/b\u003e 76 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eDistal Width:\u003c\/b\u003e 13 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eTechnology:\u003c\/b\u003e CMOS with distal LED illumination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,7,0\"\u003e\u003cb data-path-to-node=\"8,7,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Surgical-grade Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eSuperior Difficult Airway Management:\u003c\/b\u003e The D-Blade is specifically validated for Grade III and IV difficult laryngoscopy, closing the gap between standard video laryngoscopy and flexible fiberoptic intubation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eReduced Anatomical Trauma:\u003c\/b\u003e The hyperangulated shape requires less \"levering\" against the teeth and soft tissues compared to standard blades, reducing the risk of dental injury or airway edema.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eModular \"Plug \u0026amp; Play\" Integration:\u003c\/b\u003e Sourcing this \"Excellent Condition\" 8401HXP allows facilities to equip their C-MAC® systems with specialized pediatric capabilities without the expense of an entire new platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003ePediatric Anesthesiology:\u003c\/b\u003e Management of known or unexpected difficult airways in children.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eNeonatology \u0026amp; NICU:\u003c\/b\u003e Intubation of small pediatric patients with craniofacial anomalies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003ePediatric ER \u0026amp; ICU:\u003c\/b\u003e Rapid Sequence Induction (RSI) where anterior laryngeal positioning is suspected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eResidency Training:\u003c\/b\u003e A vital tool for demonstrating pediatric airway anatomy in high-fidelity simulation environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"8\"\u003eUsed — Excellent Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eOptical Integrity:\u003c\/b\u003e The distal CMOS lens and LED windows are verified clear and free of scratches, ensuring optimal light transmission and image quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eMechanical Function:\u003c\/b\u003e The C-MAC handle interface and stainless steel blade are well-maintained, showing minimal signs of prior clinical use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eCompatibility Note:\u003c\/b\u003e This listing is for the \u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"44\"\u003e8401HXP blade\/handpiece only\u003c\/b\u003e. For operation, a compatible Karl Storz C-MAC® Monitor (e.g., 8403ZX or 8401XDK) and an electronic connecting cable (8401X or 8402X) are required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Karl Storz","offers":[{"title":"Default Title","offer_id":48319313051873,"sku":"KARL8401HXP","price":680.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/primis-auctions-dotmed-4_e8c15c21-9d15-436e-bf90-0597b920add7.png?v=1778191999","url":"https:\/\/primismedical.com\/en-cn\/products\/karl-storz-8401hxp-c-mac-pediatric-d-blade-laryngoscope","provider":"Primis Medical","version":"1.0","type":"link"}