{"product_id":"lumenis-luxar-lx-20sp-novapulse-co2-laser-system-for-parts","title":"Lumenis Luxar LX-20SP NovaPulse CO2 Laser System For Parts","description":"\u003ch4 data-path-to-node=\"2\"\u003eLumenis \/ Luxar LX-20SP NovaPulse CO2 Laser | Surgical Platform\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eLuxar LX-20SP NovaPulse\u003c\/b\u003e (now under the Lumenis portfolio) is a clinically significant 10.6-micrometer CO2 laser system. Renowned for its \u003cb data-path-to-node=\"3\" data-index-in-node=\"141\"\u003eSuperPulse\u003c\/b\u003e technology, this system was engineered to deliver high peak power with short pulse durations, allowing for precise tissue ablation with minimal thermal damage to surrounding structures.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eThis specific unit is offered \u003cb data-path-to-node=\"4\" data-index-in-node=\"30\"\u003eFor Parts or Repair\u003c\/b\u003e. While the system powers on, the laser tube integrity, gas pressure, and optical alignment have not been verified. This represents a strategic acquisition for facilities seeking a donor chassis for articulated arms, power supplies, or the proprietary NovaPulse control boards.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Technical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Lumenis \/ Luxar (LuxarCare)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e LX-20SP (NovaPulse Series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eWavelength:\u003c\/b\u003e 10.6 µm (CO2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003ePower Output (Rated):\u003c\/b\u003e Up to 20 Watts (Continuous Wave) \/ 10 Watts (Average SuperPulse)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003ePeak Power:\u003c\/b\u003e 50 Watts (SuperPulse mode)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eOperating Modes:\u003c\/b\u003e * \u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"19\"\u003eCW (Continuous Wave):\u003c\/b\u003e For traditional cutting and coagulation.\u003c\/p\u003e\n\u003cul data-path-to-node=\"6,5,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,1,0,0\"\u003e\u003cb data-path-to-node=\"6,5,1,0,0\" data-index-in-node=\"0\"\u003eNovaPulse (SuperPulse):\u003c\/b\u003e For char-free ablation and \"cold\" tissue vaporization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eControl Interface:\u003c\/b\u003e Membrane switch panel with digital display for power, hertz, and duty cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eArticulated Delivery:\u003c\/b\u003e Multi-jointed mast assembly with knuckle mirrors for high-precision beam steering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eSystem Components Included\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eMobile Trolley Base:\u003c\/b\u003e Rolling chassis with heavy-duty casters and integrated storage for accessories.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eArticulated Laser Arm:\u003c\/b\u003e Multi-axial delivery system (Note: Mirrors and internal optics are unverified).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eFootswitch:\u003c\/b\u003e \u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"12\"\u003eLinemaster Treadlite II (T-91-S)\u003c\/b\u003e; industry-standard heavy-duty actuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eHandpiece Assembly:\u003c\/b\u003e Integrated aperture\/handpiece as shown in the photos.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003ePower Supply:\u003c\/b\u003e 115V internal DC power supply and RF excitation module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical \u0026amp; Technical Utility (For Parts\/Repair)\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eRF Excited Laser Tube:\u003c\/b\u003e The LX-20SP utilizes a sealed radiofrequency-excited laser tube. This component is highly sought after by refurbishment centers for regassing or as a core exchange for serviced units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eArticulated Mast \u0026amp; Knuckle Mirrors:\u003c\/b\u003e Valuable replacement parts for systems with damaged optics or compromised range of motion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eControl Electronics:\u003c\/b\u003e Includes the display circuit board and controller board, essential for repairing units with localized electronic failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eAir Pump System:\u003c\/b\u003e Integrated diaphragm pump designed to keep the fiber\/optics clear of smoke plume during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications for This Listing\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eBiomedical Engineering Labs:\u003c\/b\u003e Providing a testing platform for CO2 laser calibration and power supply diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eMedical Equipment Refurbishers:\u003c\/b\u003e Harvesting high-value components (mast, chassis, footswitch, boards) to restore other LX-20 series units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eVeterinary Practices:\u003c\/b\u003e Utilizing the chassis or non-laser components to maintain an existing Luxar fleet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCondition \u0026amp; Safety Disclosure\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"8\"\u003eUsed — Powers On \/ For Parts or Repair.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eLaser Output:\u003c\/b\u003e \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"14\"\u003eNOT TESTED.\u003c\/b\u003e The laser's ability to fire or reach rated wattage is unknown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eSafety Warning:\u003c\/b\u003e This is a \u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"26\"\u003eClass IV Laser\u003c\/b\u003e. Service and repair should only be performed by manufacturer-certified technicians or qualified biomedical engineers. Improper handling of internal components may result in hazardous radiation exposure or high-voltage electric shock.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eCompliance:\u003c\/b\u003e Maintenance of medical lasers must comply with ANSI Z136.3 standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumenis","offers":[{"title":"Default Title","offer_id":48333792674017,"sku":"LUMLX20SP","price":510.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay_752dc9b9-2ece-4583-b18b-e6d982fe28df.png?v=1778253547","url":"https:\/\/primismedical.com\/en-cn\/products\/lumenis-luxar-lx-20sp-novapulse-co2-laser-system-for-parts","provider":"Primis Medical","version":"1.0","type":"link"}