{"product_id":"olympus-clv-s190-visera-elite-xenon-light-source-300w-nbi-technology-one-touch-connector","title":"Olympus CLV-S190 VISERA ELITE Xenon Light Source - 300W, NBI Technology, One-Touch Connector","description":"\u003ch4 data-path-to-node=\"2\"\u003eOlympus VISERA ELITE Xenon Light Source | CLV-S190\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eOlympus CLV-S190\u003c\/b\u003e is a premier 300-watt medical illumination platform engineered for the 2026 standards of multi-specialty endoscopic surgery. Designed as the direct optical partner to the \u003cb data-path-to-node=\"3\" data-index-in-node=\"192\"\u003eOTV-S190 video processor\u003c\/b\u003e, this system delivers high-intensity, pure white light that is essential for rendering true 1080p HDTV clarity.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eBeyond standard white-light illumination, the CLV-S190 features built-in mechanical filter wheels that drive Olympus's proprietary \u003cb data-path-to-node=\"4\" data-index-in-node=\"131\"\u003eNarrow Band Imaging (NBI)\u003c\/b\u003e technology, allowing for enhanced visualization of microvascular networks and mucosal surface structures.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eHigh-Intensity 300W Xenon Output:\u003c\/b\u003e Provides the intense, daylight-quality illumination necessary to clear deep anatomical corridors, ensuring vivid color reproduction across general surgery, urology, and ENT applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eOptimized Narrow Band Imaging (NBI):\u003c\/b\u003e Engineered with an advanced optical filter system that delivers a significantly brighter NBI field than legacy light sources, maximizing tissue-contrast without compromising brightness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eFail-Safe Emergency Backup:\u003c\/b\u003e Features an integrated \u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"51\"\u003e12V 35W Halogen backup lamp\u003c\/b\u003e. In the rare event of a primary Xenon bulb failure, the system automatically engages the halogen backup instantly to preserve patient safety and field visualization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eIntelligent Standby Mode:\u003c\/b\u003e Built-in automated intensity controls lower the lamp output when the scope is disconnected or left idle, minimizing heat generation at the scope tip and preserving bulb longevity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eOne-Touch Scope Connection:\u003c\/b\u003e The front panel configuration allows for waterproof, one-touch connection of modern Olympus videoscopes and light guide cables without the need for manual rotation or separate adapters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Olympus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e CLV-S190 (VISERA ELITE Series)\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eSpecialized Modality:\u003c\/b\u003e Mechanical NBI Filter Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eCooling:\u003c\/b\u003e High-efficiency, quiet forced-air fan system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eWeight:\u003c\/b\u003e 15.0 kg (Approx. 33.1 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,7,0\"\u003e\u003cb data-path-to-node=\"8,7,0\" data-index-in-node=\"0\"\u003ePower Compatibility:\u003c\/b\u003e Universal 100-240V AC; 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eCentralized System Link:\u003c\/b\u003e Communicates directly with the OTV-S190 processor via a dedicated system cable, enabling the surgeon to toggle NBI or adjust light intensity via the programmable buttons on the camera head.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eMulti-Specialty Versatility:\u003c\/b\u003e Serves as a standard, high-performance backbone for cross-departmental towers, accommodating Gastroenterology (GI), Urology, Gynecology, and General Laparoscopy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eReduced Operating Room Latency:\u003c\/b\u003e The simplified, adapter-free front interface streamlines the pre-operative setup and turnover times for circulating nurses and surgical techs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eStrategic Procurement:\u003c\/b\u003e Sourcing this high-capital Olympus asset in \u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"67\"\u003e[Insert Condition]\u003c\/b\u003e enables ambulatory surgery centers (ASCs) to implement advanced diagnostic NBI capabilities while maintaining strict capital budget efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eGastroenterology:\u003c\/b\u003e High-contrast mucosal evaluation during colonoscopy and EGD.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eUrology:\u003c\/b\u003e Precise tumor visualization during cystoscopy and TURBT via NBI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eGeneral Laparoscopy:\u003c\/b\u003e Cholecystectomies and appendectomies requiring deep-cavity light saturation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eQuality Assurance \u0026amp; Condition\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"8\"\u003eUsed\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eBiomedical Validation:\u003c\/b\u003e This unit has undergone full output calibration, cooling fan verification, and optical path optimization. The mechanical NBI filter wheel has been tested for precise alignment and rapid transition responses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBulb is not included with Unit\u003c\/h4\u003e","brand":"Olympus","offers":[{"title":"Default Title","offer_id":48435682181345,"sku":"OLYMCLVS190","price":1895.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Olympus_CLV-S190_MAIN.png?v=1780414268","url":"https:\/\/primismedical.com\/en-cn\/products\/olympus-clv-s190-visera-elite-xenon-light-source-300w-nbi-technology-one-touch-connector","provider":"Primis Medical","version":"1.0","type":"link"}