{"product_id":"olympus-maj-1652-auxiliary-channel-water-adaptor-for-180-190-240-290-series-endoscopes","title":"Olympus MAJ-1652 Auxiliary Channel Water Adaptor - For 180, 190, 240, \u0026 290 Series Endoscopes","description":"\u003ch4 data-path-to-node=\"2\"\u003eOlympus Auxiliary Channel Adaptor | Sterile | Single-Use | MAJ-1652\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eOlympus MAJ-1652\u003c\/b\u003e is a mission-critical irrigation accessory engineered for the 2026 standard of care in gastrointestinal endoscopy. This sterile, single-use adaptor serves as the secure interface between an auxiliary water tube (such as the \u003cb data-path-to-node=\"3\" data-index-in-node=\"245\"\u003eMAJ-1651\u003c\/b\u003e) and the auxiliary water channel of an Olympus endoscope.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eWhen paired with a dedicated flushing pump (e.g., \u003cb data-path-to-node=\"4\" data-index-in-node=\"50\"\u003eOlympus OFP-2\u003c\/b\u003e), the MAJ-1652 enables high-pressure irrigation that clears mucosal debris, blood, and clots without occupying the scope's instrument channel. This allows clinicians to maintain a pristine visual field while simultaneously using therapeutic tools, a vital advantage during complex hemostasis and EMR procedures.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eIntegrated Check-Valve Mechanism:\u003c\/b\u003e Features a high-reliability silicone one-way valve that prevents the backflow of contaminated patient fluids into the irrigation tubing, providing a robust barrier against cross-contamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eOptimized Pressure Delivery:\u003c\/b\u003e Engineered with a polycarbonate endoscope connector designed to withstand the maximum output pressures of the OFP-2 pump, ensuring a powerful and consistent stream to the distal tip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eSterile, Single-Patient Use:\u003c\/b\u003e Eliminates the logistical burden and infection risks associated with reprocessing reusable adaptors, ensuring a fresh, patent valve for every procedure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eErgonomic Snap-Fit Design:\u003c\/b\u003e Allows for rapid, secure attachment to the auxiliary water port, minimizing setup time and preventing intra-procedural leaks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eClear Body Construction:\u003c\/b\u003e The acrylic check-valve body allows for visual verification of fluid flow, aiding the clinical team in troubleshooting irrigation issues instantly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Olympus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eProduct Code:\u003c\/b\u003e MAJ-1652\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eType:\u003c\/b\u003e Auxiliary Channel Adaptor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Polycarbonate (Connector), Acrylic (Body), Silicon (Valve)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eDimensions:\u003c\/b\u003e 12 mm Diameter x 34.3 mm Length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eCompatibility:\u003c\/b\u003e Olympus EVIS EXERA II (180), EXERA III (190), 240, 260, and 290 Series Gastrointestinal Endoscopes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003ePump Compatibility:\u003c\/b\u003e Optimized for OFP and OFP-2 Flushing Pumps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eEnhanced Visual Clarity:\u003c\/b\u003e Facilitates superior washing of the gastric and colonic mucosa, improving diagnostic accuracy and shortening procedural times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eInfection Control Compliance:\u003c\/b\u003e As a disposable component, the MAJ-1652 directly supports hospital \"Never Event\" prevention protocols by removing a potential vector for patient-to-patient pathogen transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eTherapeutic Flexibility:\u003c\/b\u003e By utilizing the auxiliary water channel, the main biopsy channel remains free for snares, needles, or forceps, allowing for uninterrupted irrigation during active interventions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eUpper GI Endoscopy (EGD):\u003c\/b\u003e Rapidly clearing gastric secretions or blood in acute GI bleeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eColonoscopy:\u003c\/b\u003e Washing away residual stool or mucus in poorly prepped patients to ensure a thorough mucosal exam.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eEndoscopic Ultrasound (EUS):\u003c\/b\u003e Providing the rapid fluid filling of organs required for optimal acoustic coupling and ultrasound imaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"8\"\u003eNEW — Genuine Olympus Overstock.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eExpiration Date:\u003c\/b\u003e 2027-11-28\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003ePackaging:\u003c\/b\u003e Original OEM individual sterile packaging; factory seals are 100% intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eInventory Value:\u003c\/b\u003e Sourcing genuine MAJ-1652 overstock provides significant cost-per-case savings for high-volume centers without compromising on OEM-validated safety and performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Olympus","offers":[{"title":"Default Title","offer_id":48274050056417,"sku":null,"price":3.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/ProductPhotos-2026-05-04T112301.457.png?v=1777915429","url":"https:\/\/primismedical.com\/en-cn\/products\/olympus-maj-1652-auxiliary-channel-water-adaptor-for-180-190-240-290-series-endoscopes","provider":"Primis Medical","version":"1.0","type":"link"}