{"product_id":"olympus-wm-np2-mobile-workstation-endoscopy-video-trolley-with-maj-1641-monitor-arm-separation-transformer","title":"Olympus WM-NP2 Mobile Workstation - Endoscopy Video Trolley with MAJ-1641 Monitor Arm \u0026 Separation Transformer","description":"\u003ch4 data-path-to-node=\"2\"\u003eOlympus WM-NP2 Mobile Workstation | EVIS EXERA II \u0026amp; III Platform\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eOlympus WM-NP2\u003c\/b\u003e is the industry-standard mobile imaging platform, engineered specifically for the 2026 demands of the \u003cb data-path-to-node=\"3\" data-index-in-node=\"121\"\u003eEVIS EXERA® III\u003c\/b\u003e and legacy EXERA II systems. More than a simple cart, the WM-NP2 is a sophisticated \"tower\" solution that centralizes power, cable management, and high-load endoscopic equipment into a compact, 650mm-wide footprint.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eDesigned for the high-turnover environment of GI and surgical suites, the WM-NP2 balances a heavy-duty load capacity with refined ergonomics, ensuring that processors, light sources, and monitors are safe, mobile, and positioned for peak clinical efficiency.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eIntegrated Separation Transformer (MAJ-1647):\u003c\/b\u003e Features a medical-grade 110-120V transformer that centralizes the tower’s power supply. This ensures all sensitive imaging equipment is powered via a single master switch, protecting circuitry from power surges and maintaining strict electrical leakage compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eGas-Spring Monitor Arm (MAJ-1641):\u003c\/b\u003e The heavy-duty LCD arm features an integral gas spring for effortless, balanced adjustment. Clinicians can tilt, swivel, and height-adjust the monitor for a zero-strain viewing angle, even during long, complex procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eIntelligent Cable Architecture:\u003c\/b\u003e Built-in cable channels within the aluminum workstation hoops and dedicated rear-shelf winders eliminate \"cord clutter.\" This increases OR safety and prevents accidental cable disconnects during cart transport.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003e\"Clip-In\" Customization:\u003c\/b\u003e A modular rail system supports rapid attachment of procedure-specific accessories, including CO2 cylinder holders (MAJ-1653), water bottle clips, and specialized scope poles (MAJ-1638).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eHigh-Load Mobility:\u003c\/b\u003e Despite its 85 kg (unladen) weight, the cart features four high-durability, smooth-rolling casters with front-locking brakes. Ergonomic handles on the front, side, and rear of the top tray provide precise maneuverability when fully loaded.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Olympus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e WM-NP2 (Second Generation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eDimensions:\u003c\/b\u003e 1826mm (H) x 700mm (D) x 650mm (W)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eConstruction:\u003c\/b\u003e Profiled aluminum hoops, milled steel shelves, and injection-molded ABS top tray.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eTransformer:\u003c\/b\u003e MAJ-1647 (110-120V Series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eMax Load Capacity:\u003c\/b\u003e ~85 kg (including fitted transformer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eCompatible Systems:\u003c\/b\u003e Olympus EVIS EXERA III (CV-190), EXERA II (CV-180), and Surgical Platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eMaximized Space Utilization:\u003c\/b\u003e Its narrow design (650mm) allows the endoscopy tower to be positioned closer to the procedure table without obstructing the staff’s range of motion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eStandardized Safety:\u003c\/b\u003e The central on\/off switch allows for a \"one-touch\" shutdown, critical for facility-wide power management and emergency protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eImproved Ergonomics:\u003c\/b\u003e The MAJ-1641 monitor arm reduces neck and eye strain, a critical factor for physician longevity in high-volume endoscopy units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eStrategic Procurement:\u003c\/b\u003e Acquiring this \"Standard-Setting\" workstation in \u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"72\"\u003e[Specify: New \/ Demo \/ Refurbished]\u003c\/b\u003e condition provides a premium Olympus platform at a significant reduction in capital expenditure compared to brand-new tower configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eGastroenterology (GI):\u003c\/b\u003e Primary tower for EGD and Colonoscopy suites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eENT \u0026amp; Bronchoscopy:\u003c\/b\u003e Compact enough for smaller outpatient clinics and ICU bedside use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eSurgical Endoscopy:\u003c\/b\u003e Supporting laparoscopic towers in the integrated OR.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"8\"\u003eUsed - Good condition, slight cosmetic blemishes.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eElectrical Validation:\u003c\/b\u003e The separation transformer has been biomedically tested for continuity and leakage current to meet 2026 hospital safety standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eMechanical Status:\u003c\/b\u003e Casters and monitor arm gas springs have been verified for smooth operation under load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eIncluded Components:\u003c\/b\u003e WM-NP2 Chassis, MAJ-1647 Transformer, MAJ-1641 Monitor Arm, and integrated shelving. (Keyboards and Scope Poles are modular add-ons).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Olympus","offers":[{"title":"Default Title","offer_id":48417810022625,"sku":"OLYMWMNP2","price":1495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Olympus_WM-NP2_MAIN.png?v=1779986848","url":"https:\/\/primismedical.com\/en-cn\/products\/olympus-wm-np2-mobile-workstation-endoscopy-video-trolley-with-maj-1641-monitor-arm-separation-transformer","provider":"Primis Medical","version":"1.0","type":"link"}