{"product_id":"stryker-0242-200-001-hip-arthroscopy-cannula-5-5mm","title":"Stryker 0242-200-001 Hip Arthroscopy Cannula 5.5mm","description":"\u003ch4 data-path-to-node=\"2\"\u003eStryker Hip Arthroscopy Cannula | Slotted | 5.5mm Diameter | 0242-200-001\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eStryker 0242-200-001\u003c\/b\u003e is a specialized high-flow access instrument engineered for the unique challenges of hip arthroscopy. Due to the deep nature of the hip joint and the thick soft tissue envelope (the \"thigh\") that must be traversed, this cannula features an extended \u003cb data-path-to-node=\"3\" data-index-in-node=\"274\"\u003e9-inch (230mm) shaft\u003c\/b\u003e. This provides a stable, protected portal from the skin incision through the joint capsule, ensuring that instruments can be exchanged rapidly without losing the surgical tract.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003e5.5mm diameter\u003c\/b\u003e is specifically calibrated to accommodate standard arthroscopic shavers, burrs, and probes, while the \u003cb data-path-to-node=\"4\" data-index-in-node=\"121\"\u003eslotted distal design\u003c\/b\u003e facilitates superior fluid irrigation and outflow, maintaining clear visualization even during high-debris procedures like labral debridement or acetabular rim trimming.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Stryker\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 0242-200-001\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eProduct Type:\u003c\/b\u003e Slotted Hip Arthroscopy Cannula\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eShaft Diameter:\u003c\/b\u003e 5.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eShaft Length:\u003c\/b\u003e 9 inches (230 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Medical-Grade Stainless Steel (Shaft) \/ Ergonomic Polymer (Handle)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eDesign:\u003c\/b\u003e Slotted (Fenestrated Distal Tip)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eSterility:\u003c\/b\u003e Reusable (Requires sterilization)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eExtended Reach for Hip Access:\u003c\/b\u003e The 9-inch shaft length is essential for reaching the central and peripheral compartments of the hip joint, providing a clear corridor through the gluteal and capsular layers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eSlotted Fluid Dynamics:\u003c\/b\u003e The distal slots prevent \"vacuum locking\" of instruments and support constant irrigation. This is critical for washing out bone \"mud\" during cam or pincer lesion resections (femoroacetabular impingement - FAI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eHigh-Strength Rigid Construction:\u003c\/b\u003e Unlike flexible cannulas, the rigid stainless steel shaft resists bending under the significant soft-tissue tension characteristic of hip distraction, ensuring the portal remains patent throughout the procedure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eErgonomic \"T-Grip\" Handle:\u003c\/b\u003e The integrated handle provides the surgeon with superior leverage for controlled capsular penetration and precise intra-articular positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003ePortal Integrity:\u003c\/b\u003e By providing a fixed channel, the 0242-200-001 prevents \"skiving\" and repeated trauma to the soft tissues during instrument exchanges, which reduces post-operative swelling and pain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eSports Medicine:\u003c\/b\u003e Primary and revision hip arthroscopy for labral repair or reconstruction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eFAI Correction:\u003c\/b\u003e Providing access for burrs during acetabular rim trimming and femoral neck osteoplasty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eDiagnostic Arthroscopy:\u003c\/b\u003e Facilitating visualization and biopsy of the ligamentum teres or synovial lining.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eLoose Body Removal:\u003c\/b\u003e Creating a safe exit path for the retrieval of osteochondral fragments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eUsed — In Good Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eIntegrity:\u003c\/b\u003e The stainless steel shaft is perfectly straight with no burrs or nicks along the slotted edges. The handle-to-shaft connection is secure and free of play.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eMaintenance Requirement:\u003c\/b\u003e As a \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"30\"\u003ereusable surgical instrument\u003c\/b\u003e, this cannula must be processed through a validated decontamination and sterilization cycle (standard steam autoclave) in accordance with hospital protocols and Stryker’s Instructions for Use (IFU) prior to clinical use in 2026.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eProfessional Standards:\u003c\/b\u003e With over \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"34\"\u003e25 years of experience\u003c\/b\u003e in orthopedic hardware, \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"81\"\u003ePrimis Medical\u003c\/b\u003e ensures all arthroscopic access tools are inspected for mechanical and structural reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in reinforced protective packaging to ensure the 9-inch shaft remains perfectly aligned and protected from transit shock.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay_0b1e5be5-d394-43cf-9d18-13316fe64050.png?v=1775495369\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":48183816618209,"sku":"STRY0242200001","price":323.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay_5d66f6bc-b323-4bd5-92e7-b80ea7a97123.png?v=1775495273","url":"https:\/\/primismedical.com\/en-cn\/products\/stryker-0242-200-001-hip-arthroscopy-cannula-5-5mm","provider":"Primis Medical","version":"1.0","type":"link"}