{"product_id":"synthes-201-618-2-4mm-cortex-screw-self-tapping-18mm-copy","title":"Synthes 309.200 Hollow Reamer-Complete for 2.0mm Screws","description":"\u003ch4 data-path-to-node=\"2\"\u003eSynthes Hollow Reamer-Complete | For 2.0mm Screws | 3\" Length | 309.200\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eSynthes 309.200\u003c\/b\u003e is a specialized salvage instrument engineered for the difficult removal of \u003cb data-path-to-node=\"3\" data-index-in-node=\"96\"\u003e2.0mm cortex screws\u003c\/b\u003e. It is a critical component of the \u003cb data-path-to-node=\"3\" data-index-in-node=\"151\"\u003eSynthes Mini-Fragment Screw Removal Set\u003c\/b\u003e, specifically designed for \"worst-case\" scenarios where a screw head is stripped, sheared off, or cold-welded to a plate, rendering standard drivers and extraction screws ineffective.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eUnlike extraction screws that engage the internal drive or cannulation, the \u003cb data-path-to-node=\"4\" data-index-in-node=\"76\"\u003eHollow Reamer\u003c\/b\u003e works by cutting a minimal circular trench around the perimeter of the screw shank. This \"over-coring\" technique releases the bone-to-thread interface, allowing the damaged hardware to be lifted out with minimal disruption to the surrounding cortical architecture.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Synthes (DePuy Synthes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 309.200\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eCompatibility:\u003c\/b\u003e 2.0 mm Cortex Screws\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eOverall Length:\u003c\/b\u003e 3 inches (~76 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Hardened Surgical-Grade Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eShank Type:\u003c\/b\u003e Quick Coupling (QC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eComponents included:\u003c\/b\u003e Hollow Reamer Bit + Centering Pin (309.170)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eQuantity:\u003c\/b\u003e 1 Each\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eCounter-Clockwise Cutting:\u003c\/b\u003e The reamer is engineered with left-hand (reverse) cutting flutes. This ensures that as the tool cuts into the bone, the rotational friction actually encourages the screw to back out rather than driving it deeper into the fragment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003ePrecision Centering:\u003c\/b\u003e The system includes the \u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"45\"\u003e309.170 Centering Pin\u003c\/b\u003e, which fits into the hollow bore of the reamer. This pin acts as a guide to keep the reamer perfectly coaxial with the screw shaft, preventing \"skating\" across the bone surface and protecting adjacent soft tissues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eBone-Preserving Diameter:\u003c\/b\u003e The thin-walled construction of the reamer is designed to remove only the absolute minimum amount of bone necessary to break the screw's purchase. This is vital in hand and foot surgery where bone stock is limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eQuick-Coupling (QC) Integration:\u003c\/b\u003e Designed for use with the \u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"59\"\u003eSynthes 311.44 T-Handle\u003c\/b\u003e or other QC manual drivers. Manual extraction provides the surgeon with the high-fidelity tactile feedback required to avoid breaking the reamer or further damaging the bone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eHigh Torsional Durability:\u003c\/b\u003e Forged from vacuum-melted, hardened stainless steel, the 309.200 maintains its sharp cutting edge through dense cortical bone, ensuring a clean and efficient extraction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eHardware Revision:\u003c\/b\u003e Removal of stripped or damaged 2.0mm screws from the phalanges, metacarpals, or midface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eBroken Screw Retrieval:\u003c\/b\u003e Extracting screw shanks that have snapped off at or below the bone surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eCold-Weld Release:\u003c\/b\u003e Freeing 2.0mm screws that have become stuck in non-locking or locking plates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eHand \u0026amp; Small Fragment Trauma:\u003c\/b\u003e Salvaging fixation failures in 2026 where primary removal tools have failed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eNEW — Open Package.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eIntegrity:\u003c\/b\u003e This instrument is unused and maintains its factory-sharp reverse-cutting flutes and structural alignment. The inner and outer packaging is intact, ensuring the product's suitability for clinical use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eSterilization Note:\u003c\/b\u003e This is a \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"30\"\u003eNON-STERILE, REUSABLE\u003c\/b\u003e instrument. It MUST be thoroughly cleaned (with special attention to the hollow bore) and sterilized via validated steam autoclave protocols in accordance with facility guidelines and Synthes’ Instructions for Use (IFU) prior to clinical application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eProfessional Standards:\u003c\/b\u003e With over \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"34\"\u003e25 years of experience\u003c\/b\u003e in surgical logistics, \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"80\"\u003ePrimis Medical\u003c\/b\u003e ensures all specialized extraction tools are stored and handled to preserve their mechanical precision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in protective, rigid packaging to ensure the cutting flutes and centering pin remain pristine during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/mceclip34_175691952468b876e41d1967876.png?v=1756919525\" style=\"font-size: 0.875rem;\"\u003e\u003c\/h2\u003e","brand":"Synthes","offers":[{"title":"Default Title","offer_id":46229070840033,"sku":"SYNT-309.200","price":167.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Shopify_-_2025-03-05T160543.121.jpg?v=1752113984","url":"https:\/\/primismedical.com\/en-cn\/products\/synthes-201-618-2-4mm-cortex-screw-self-tapping-18mm-copy","provider":"Primis Medical","version":"1.0","type":"link"}