{"product_id":"synthes-310-63-5-0mm-cannulated-drill-bit-large-quick-connect-11-3-4","title":"Synthes 310.63 5.0mm Cannulated Drill Bit Large Quick Connect 11-3\/4\"","description":"\u003ch4 data-path-to-node=\"2\"\u003eSynthes 5.0 mm Cannulated Drill Bit | Large Quick Connect | 310.63\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eSynthes 310.63\u003c\/b\u003e is a specialized orthopedic instrument engineered for high-precision bone preparation, particularly in large-fragment fixation. With a \u003cb data-path-to-node=\"3\" data-index-in-node=\"154\"\u003e5.0 mm diameter\u003c\/b\u003e and an internal \u003cb data-path-to-node=\"3\" data-index-in-node=\"186\"\u003e2.9 mm cannulation\u003c\/b\u003e, this bit is designed to track accurately over guide wires (K-wires), ensuring the concentric alignment required for the subsequent placement of \u003cb data-path-to-node=\"3\" data-index-in-node=\"350\"\u003e6.5 mm and 7.3 mm cannulated screws\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eMeasuring approximately \u003cb data-path-to-node=\"4\" data-index-in-node=\"24\"\u003e300 mm (11-3\/4 inches)\u003c\/b\u003e, the 310.63 provides the extended reach necessary for deep anatomical sites, such as the femoral neck, calcaneus, or periprosthetic fractures, where standard-length bits may fall short.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eCannulated Precision (2.9 mm ID):\u003c\/b\u003e The internal lumen is specifically calibrated to slide over a standard guide wire. This \"path-following\" design is critical for percutaneous and minimally invasive techniques, preventing bit \"walking\" and ensuring the screw trajectory remains perfectly centered.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eExtended Reach (300 mm):\u003c\/b\u003e The 11-3\/4 inch profile allows surgeons to maintain clear visibility and control when working in deep or confined anatomical zones, or when drilling through significant soft-tissue envelopes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eLarge Quick-Connect Interface:\u003c\/b\u003e Specifically engineered for the \u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"63\"\u003eSynthes Large Quick Coupling\u003c\/b\u003e system. This allows for rapid, one-handed attachment and removal from power drivers, reducing operative time and improving surgical flow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eOptimized Flute Geometry:\u003c\/b\u003e Designed to efficiently evacuate bone debris (swarf) through the extended shaft, reducing heat buildup and the risk of thermal necrosis during deep-channel drilling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eHigh-Grade Surgical Steel:\u003c\/b\u003e Manufactured by Synthes to withstand the high torque requirements of large-fragment orthopedic trauma and reconstructive surgery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Synthes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eProduct Code:\u003c\/b\u003e 310.63\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eDrill Diameter:\u003c\/b\u003e 5.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eCannulation Diameter:\u003c\/b\u003e 2.9 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eOverall Length:\u003c\/b\u003e 300 mm (11-3\/4\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eShank Type:\u003c\/b\u003e Large Quick Connect (QC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eCompatibility:\u003c\/b\u003e 6.5 mm and 7.3 mm Cannulated Screw Sets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eImproved Implant Accuracy:\u003c\/b\u003e By tracking over a pre-placed guide wire, the 310.63 minimizes the risk of cortical breakout, which is essential when placing screws in the narrow corridors of the pelvis or femoral neck.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eProcedural Versatility:\u003c\/b\u003e The large quick-connect shank is compatible with most standard orthopedic power systems (System 6, 7, and 8), making it a versatile addition to any trauma or total joint tray.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eSustainable Procurement:\u003c\/b\u003e Utilizing a \"Used-SI\" Synthes component allows facilities to maintain high-specification OEM standards for their trauma sets while achieving significant cost savings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eHip Surgery:\u003c\/b\u003e Cannulated screw fixation for femoral neck fractures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eTrauma:\u003c\/b\u003e Slipped Capital Femoral Epiphysis (SCFE) pinning and complex pilon fractures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eHindfoot Procedures:\u003c\/b\u003e Subtalar and calcaneal arthrodesis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eLong Bone Fixation:\u003c\/b\u003e Targeted drilling for intramedullary nail interlocking bolts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"8\"\u003eUsed Surgical Instrument (USED-SI).\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eIntegrity:\u003c\/b\u003e Shows visible signs of wear consistent with prior clinical use. The cannulation is clear and patent; the quick-connect shank and cutting flutes remain in usable condition for continued medical procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eReprocessing Note:\u003c\/b\u003e As a used surgical instrument, this item must undergo standard hospital cleaning and sterilization (autoclave) protocols prior to clinical use. It is recommended to inspect the cutting edges for sharpness as part of standard pre-operative tray assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/mceclip25_1755207251689e5653d789f5958.png?v=1755207253\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Synthes","offers":[{"title":"Default Title","offer_id":46368573227233,"sku":"SYNT-310.63","price":67.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay-2025-01-20t160815353.jpg?v=1752120868","url":"https:\/\/primismedical.com\/en-cn\/products\/synthes-310-63-5-0mm-cannulated-drill-bit-large-quick-connect-11-3-4","provider":"Primis Medical","version":"1.0","type":"link"}