{"product_id":"v-mueller-au19090-ent-schuknecht-wire-crimper-narrow-jaws-3-1-8","title":"V. Mueller AU19090 ENT Schuknecht Wire Crimper Narrow Jaws 3-1\/8\"","description":"\u003ch4 data-path-to-node=\"2\"\u003eV. Mueller AU19090 Schuknecht Wire Crimper | 3-1\/8\" Narrow Jaws | Stainless Steel | ENT\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eV. Mueller AU19090 Schuknecht Wire Crimper\u003c\/b\u003e is a premier microsurgical instrument designed for the final, critical stage of stapes surgery. Specifically engineered for the \u003cb data-path-to-node=\"3\" data-index-in-node=\"175\"\u003eSchuknecht technique\u003c\/b\u003e, these forceps are used to crimp the wire loop of a stapes prosthesis onto the long process of the incus.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eForged from high-tempered surgical stainless steel, the AU19090 features \u003cb data-path-to-node=\"4\" data-index-in-node=\"73\"\u003eultra-narrow jaws\u003c\/b\u003e that provide the surgeon with maximum visibility under the operative microscope. This design ensures that the wire loop can be closed with absolute tactile feedback, securing the prosthesis without causing pressure necrosis or mechanical trauma to the fragile ossicular chain.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e V. Mueller (Cardinal Health)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e AU19090\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eProduct Type:\u003c\/b\u003e Schuknecht Wire Crimping Forceps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eSpecialty:\u003c\/b\u003e Otology \/ Neurotology (ENT)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eWorking Length:\u003c\/b\u003e 3-1\/8 Inches (7.9 cm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eJaw Configuration:\u003c\/b\u003e Narrow Profile \/ Microsurgical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Premium Surgical Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eReusability:\u003c\/b\u003e Fully Reusable \/ Autoclavable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eNarrow Jaw Geometry:\u003c\/b\u003e The specialized narrow profile of the Schuknecht jaws allows for deeper access into the middle ear cavity. This reduces the footprint of the instrument in the surgical field, ensuring the surgeon maintains a clear line of sight to the incudostapedial joint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eCalibrated Tactile Control:\u003c\/b\u003e The 3-1\/8\" working length provides a short, direct mechanical advantage. This allows the surgeon to feel the exact moment the wire loop meets the bone, facilitating a \"snug\" fit that is essential for effective sound conduction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eAtraumatic Performance:\u003c\/b\u003e Unlike standard pliers, the AU19090 jaws are hones to apply uniform, parallel pressure. This prevents the wire from twisting or \"springing\" during the crimping process, which could otherwise displace the prosthesis from the oval window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eErgonomic Design:\u003c\/b\u003e The handle-to-tip ratio is optimized for use through an ear speculum. The balanced weight ensures steady, tremor-free manipulation during the highest-stakes portion of the procedure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eV. Mueller Metallurgy:\u003c\/b\u003e The high-grade stainless steel construction ensures the jaws remain perfectly aligned and the hinge remains smooth through years of high-frequency sterilization and clinical use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eCondition:\u003c\/b\u003e \u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"11\"\u003eUsed – Excellent Clinical Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eIntegrity:\u003c\/b\u003e This instrument has been meticulously inspected for jaw parallelism and hinge tension. The narrow crimping surfaces are smooth, free of pitting, and perfectly aligned, ensuring 100% functional readiness for otologic microsurgery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eProfessional Processing:\u003c\/b\u003e \u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"25\"\u003ePrimis Medical\u003c\/b\u003e utilizes an extensive cleaning and disinfection protocol for all pre-owned surgical assets. Our staff, with over \u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"153\"\u003e25 years of experience\u003c\/b\u003e, ensures that each instrument meets AAMI and manufacturer standards for hospital readiness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eRegulatory Compliance:\u003c\/b\u003e As a Class II surgical instrument, the sale of this item is subject to FDA regulation. We will verify your status as an authorized medical purchaser prior to shipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Due to the delicate nature of the narrow jaws, this instrument will be shipped with a protective tip-guard in a reinforced, custom-padded container to ensure safe arrival.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay_4504350f-9343-4eef-a4e9-d2e871b9fd9f.png?v=1774545022\" alt=\"\"\u003e\u003c\/p\u003e","brand":"V. Mueller","offers":[{"title":"Default Title","offer_id":48137995354337,"sku":"S17K3-13","price":68.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay_7b66713d-3457-420a-a4aa-32646609d0b4.png?v=1774544948","url":"https:\/\/primismedical.com\/en-cn\/products\/v-mueller-au19090-ent-schuknecht-wire-crimper-narrow-jaws-3-1-8","provider":"Primis Medical","version":"1.0","type":"link"}