{"product_id":"v-mueller-au21009-austin-attic-dissector-tip-6-1-4-ent-angled","title":"V. Mueller AU21009 Austin Attic Dissector Tip 6 1\/4\" ENT Angled","description":"\u003ch4 data-path-to-node=\"2\"\u003eV. Mueller AU21009 Austin Attic Dissector | 5mm Angled Tip | 6-1\/4\" | Stainless Steel\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eV. Mueller AU21009\u003c\/b\u003e is a high-precision microsurgical instrument specifically engineered for navigating the complex anatomy of the \u003cb data-path-to-node=\"3\" data-index-in-node=\"134\"\u003eepitympanic recess (attic)\u003c\/b\u003e. Named for its specialized \"Austin\" geometry, this dissector features a fine \u003cb data-path-to-node=\"3\" data-index-in-node=\"238\"\u003e5mm angled tip\u003c\/b\u003e designed to reach behind the scutum and into the attic to safely elevate squamous epithelium or debride cholesteatoma matrix from the ossicular chain.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eWith a \u003cb data-path-to-node=\"4\" data-index-in-node=\"7\"\u003e2-3\/4 inch working length\u003c\/b\u003e and a slim-profile shaft, the AU21009 is balanced for the extreme tactile sensitivity required when working in proximity to the facial nerve and the tegmen tympani. Its design ensures that the surgeon maintains a clear line of sight through the surgical microscope, even in the most confined anatomical corridors.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e V. Mueller (BD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e AU21009\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eProduct Type:\u003c\/b\u003e Austin Attic Dissector \/ Micro-Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eTip Configuration:\u003c\/b\u003e 5mm Fine Angled Dissector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eWorking Length:\u003c\/b\u003e 2-3\/4 Inches (70mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eOverall Length:\u003c\/b\u003e 6-1\/4 Inches (159mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Medical-grade Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eHandle Type:\u003c\/b\u003e Ergonomic, hexagonal non-slip grip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,8,0\"\u003e\u003cb data-path-to-node=\"6,8,0\" data-index-in-node=\"0\"\u003eSterilization:\u003c\/b\u003e Fully Autoclavable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eOptimized Attic Access:\u003c\/b\u003e The 5mm angled tip is specifically \"bent\" to clear the bony overhang of the ear canal, allowing the surgeon to \"hook\" and pull tissue from the hidden recesses of the middle ear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eMicro-Surgical Precision:\u003c\/b\u003e The ultra-slim shaft prevents \"instrument crowding\" within the ear speculum, ensuring that the surgeon can visualize the tip's engagement with the tissue at all times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eTactile Feedback:\u003c\/b\u003e The 6-1\/4\" total length and lightweight stainless steel construction provide superior feedback, which is essential for distinguishing between pathological matrix and delicate middle ear mucosa.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eNon-Glare Satin Finish:\u003c\/b\u003e Engineered to reduce \"flash-back\" or light bounce-back under high-intensity microscopic illumination, minimizing eye strain during lengthy reconstructive cases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eDurable Construction:\u003c\/b\u003e Made from high-tensile surgical stainless steel that maintains its tip geometry and resists corrosion through thousands of high-temperature sterilization cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"8\"\u003eNew – Original Manufacturer Packaging.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eIntegrity:\u003c\/b\u003e This instrument is brand new and has never been used. It remains in its original factory packaging (opened only for quality verification and photography).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eFunctional Inspection:\u003c\/b\u003e The 5mm tip has been micro-inspected for perfect symmetry and smoothness, ensuring a \"theatre-ready\" tool for immediate clinical use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eExpertise:\u003c\/b\u003e With over \u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"21\"\u003e25 years of experience\u003c\/b\u003e in ENT instrumentation, \u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"68\"\u003ePrimis Medical\u003c\/b\u003e ensures that every V. Mueller micro-instrument meets the exacting tolerances required for otologic surgery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in a reinforced protective sleeve to ensure the delicate 5mm angled tip remains perfectly calibrated during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"V. Mueller","offers":[{"title":"Default Title","offer_id":48134005784801,"sku":"BIN 44-4","price":76.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay-5_f8660cf7-4ebc-4f26-acd6-d65be4427f59.png?v=1774472426","url":"https:\/\/primismedical.com\/en-cn\/products\/v-mueller-au21009-austin-attic-dissector-tip-6-1-4-ent-angled","provider":"Primis Medical","version":"1.0","type":"link"}