{"product_id":"varian-medical-systems-rad-14-medical-x-ray-tube-assembly-dia150kv","title":"Varian Medical Systems RAD-14 Medical X-Ray Tube Assembly DIA150KV","description":"\u003ch4 data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eVarian Medical Systems RAD-14 X-Ray Tube Assembly (Housing: DIA150KV)\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"8\"\u003eThe \u003cb data-path-to-node=\"8\" data-index-in-node=\"4\"\u003eVarian RAD-14\u003c\/b\u003e is a professional-grade rotating anode X-ray tube assembly engineered for demanding diagnostic applications. Mounted within the \u003cb data-path-to-node=\"8\" data-index-in-node=\"146\"\u003eDIA150KV housing\u003c\/b\u003e, this unit is rated for a maximum potential of \u003cb data-path-to-node=\"8\" data-index-in-node=\"210\"\u003e150 kVp\u003c\/b\u003e, providing the penetration power necessary for bariatric imaging and complex lateral views. The \u003cb data-path-to-node=\"8\" data-index-in-node=\"314\"\u003edual focal spot sizes (0.6 mm for fine detail and 1.2 mm for high-power loads)\u003c\/b\u003e offer the clinical flexibility required for a modern general radiography suite.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eThis assembly includes the original housing, stator leads, and mounting hardware. With a permanent filtration of \u003cb data-path-to-node=\"9\" data-index-in-node=\"113\"\u003e0.7 mm Al at 75 kV\u003c\/b\u003e, this unit meets standard regulatory requirements for beam hardening. As a surplus imaging component, this assembly is an excellent candidate for equipment refurbishment, glass-ware harvesting, or as a high-value source of components for specialized research and development.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eKey Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Varian Medical Systems (Varex Imaging)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eTube Type:\u003c\/b\u003e RAD-14\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eHousing Model:\u003c\/b\u003e DIA150KV (150 kVp Max)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\" id=\"p-rc_49c34b30487466fd-292\"\u003e\u003cspan class=\"citation-499\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-499\"\u003eFocal Spots:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-499 citation-end-499\"\u003e 0.6 \/ 1.2 (Dual)\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003cbutton class=\"button ng-star-inserted\" aria-label=\"View source details for citation from DirectMed Imaging. Opens side panel.\"\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/button\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003ePermanent Filtration:\u003c\/b\u003e 0.7 Al \/ 75\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eStator Type:\u003c\/b\u003e R-Stator Configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-path-to-node=\"11,6,0\" data-index-in-node=\"0\"\u003eCompliance:\u003c\/b\u003e HHS 21 CFR Subchapter J \/ CE \/ cRUus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\"\u003e\u003cb data-path-to-node=\"11,7,0\" data-index-in-node=\"0\"\u003eManufacture Date:\u003c\/b\u003e September 2008\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,8,0\"\u003e\u003cb data-path-to-node=\"11,8,0\" data-index-in-node=\"0\"\u003eOrigin:\u003c\/b\u003e Salt Lake City, Utah, USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eTechnical \u0026amp; Professional Considerations\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eHigh Thermal Capacity:\u003c\/b\u003e The DIA150KV housing is designed for efficient heat dissipation, supporting high-volume patient workflows without excessive cooling delays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003ePrecision Engineering:\u003c\/b\u003e Varian’s R-series stators provide reliable anode rotation, essential for maintaining focal track integrity during high-mA exposures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eModular Integration:\u003c\/b\u003e Standard electrical connection leads and mounting points facilitate integration into a variety of compatible X-ray stands and overhead tube cranes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eRegulatory Compliance:\u003c\/b\u003e Fully labeled for medical use in the United States and Europe, ensuring traceable manufacturing standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eCondition\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"8\"\u003eUsed – Removed from Service.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eFunctionality:\u003c\/b\u003e \u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"15\"\u003eUntested \/ Sold As-Is.\u003c\/b\u003e This unit was removed from a working clinical environment during a facility upgrade but has not been functionally tested since removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eCosmetic Status:\u003c\/b\u003e Shows signs of professional installation, including typical surface scuffs, residue, and mounting marks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eSARUP Compliance:\u003c\/b\u003e No patient data is stored on this mechanical assembly; however, any associated control computers or hard drives have been removed for HIPAA compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eWarranty \u0026amp; Terms\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003e\u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"0\"\u003e✔ Sold \"As-Is \/ For Parts\":\u003c\/b\u003e No warranty is expressed or implied regarding the functional life of the vacuum or the integrity of the focal track.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003e\u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"0\"\u003eInspection:\u003c\/b\u003e It is strongly recommended that a qualified medical physicist or imaging engineer inspect and season the tube according to manufacturer protocols prior to any attempt at clinical operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eShipping\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eProfessional Heavy-Duty Shipping.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,1,0\"\u003eShips within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eDimensions:\u003c\/b\u003e 19\" x 12\" x 9\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,3,0\"\u003ePackaged with extreme care using high-density foam to protect the glass insert and high-voltage receptacles during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Varian","offers":[{"title":"Default Title","offer_id":48122688209121,"sku":"HVR","price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay-5_93da76e9-6c17-4f75-8215-ecd4de912226.png?v=1774295583","url":"https:\/\/primismedical.com\/en-cn\/products\/varian-medical-systems-rad-14-medical-x-ray-tube-assembly-dia150kv","provider":"Primis Medical","version":"1.0","type":"link"}