{"product_id":"zimmer-2360-11-02-reduction-sleeve-3-5-2-7mm-surgical-instrument","title":"Zimmer 2360-11-02 Reduction Sleeve 3.5\/2.7mm Orthopedic","description":"\u003cdiv id=\"inkfrog_crosspromo_top\"\u003e\u003c\/div\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eZimmer Reduction Sleeve | 3.5mm to 2.7mm | Orthopedic Trauma | 2360-11-02 | Reusable\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eZimmer 2360-11-02\u003c\/b\u003e is a high-precision cannulated guide sleeve engineered for the \"nested\" preparation of screw holes during complex fracture fixations. Specifically designed for use within \u003cb data-path-to-node=\"3\" data-index-in-node=\"193\"\u003eZimmer Biomet’s Small Fragment and Periarticular Locking Systems\u003c\/b\u003e, this reduction sleeve acts as a concentric spacer. It allows a \u003cb data-path-to-node=\"3\" data-index-in-node=\"322\"\u003e2.7mm drill bit or guide wire\u003c\/b\u003e to be perfectly centered within a \u003cb data-path-to-node=\"3\" data-index-in-node=\"386\"\u003e3.5mm drill guide or locking plate hole\u003c\/b\u003e, ensuring absolute axial alignment before final hardware insertion.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eBy bridging the gap between 3.5mm and 2.7mm instrument footprints, the 2360-11-02 provides the \"telescoping\" accuracy required for lag-screw techniques and fixed-angle plating where even a sub-millimeter deviation in the pilot hole can compromise the mechanical integrity of the locking construct.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Zimmer Biomet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 2360-11-02\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eProduct Type:\u003c\/b\u003e Reduction \/ Centering Sleeve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eOuter Diameter Compatibility:\u003c\/b\u003e 3.5mm Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eInner Diameter Compatibility:\u003c\/b\u003e 2.7mm Instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Medical-Grade Surgical Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eConfiguration:\u003c\/b\u003e Cannulated \/ Nested Guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eCleaning:\u003c\/b\u003e Fully Autoclavable \/ Reusable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eConcentric Alignment Precision:\u003c\/b\u003e The 2360-11-02 eliminates \"drill wander\" when transitioning between different screw sizes. It ensures that a 2.7mm pilot hole is drilled exactly in the center of a 3.5mm aperture, which is critical for the \"gliding hole\" principle in lag-screw fixation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eSeamless System Integration:\u003c\/b\u003e This sleeve is a modular component designed to fit into standard Zimmer reduction handles and spin knobs. This allows for rapid intraoperative adjustments without switching out entire drill guide assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eEnhanced Trauma Workflow:\u003c\/b\u003e In comminuted fractures where space is limited, this reduction sleeve allows the surgeon to use 2.7mm screws within a 3.5mm plate construct, providing the flexibility to adapt to the patient’s specific bone morphology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eLow-Profile Surgical Access:\u003c\/b\u003e The slim, knurled-top design allows for easy manual insertion and removal from drill guides, even when used deep within soft-tissue corridors or under fluoroscopic guidance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eIndustrial-Grade Durability:\u003c\/b\u003e Forged from high-tensile stainless steel, the sleeve maintains its thin-walled structural integrity and internal diameter tolerances through hundreds of high-torque drilling and sterilization cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eOrthopedic Trauma:\u003c\/b\u003e Internal fixation of distal radius, fibula, and humerus fractures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003ePeriarticular Plating:\u003c\/b\u003e Centering 2.7mm screws within 3.5mm locking plate holes for multi-fragment stabilization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eLag Screw Technique:\u003c\/b\u003e Preparing the \"pilot hole\" component of a 3.5mm\/2.7mm lag screw construct.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eSmall Fragment Reconstruction:\u003c\/b\u003e Any procedure requiring nested instrumentation within Zimmer's Universal Locking System (ULS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eUsed – Good Usable Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eMaintenance:\u003c\/b\u003e This instrument shows visible signs of professional use (minor surface scuffs or cosmetic wear consistent with standard tray storage and repeated autoclaving), but it remains \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"188\"\u003efully functional\u003c\/b\u003e. The internal lumen is clear and unobstructed, the 3.5\/2.7mm tolerances are factory-spec, and the stainless steel is free of pitting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eProfessional Standards:\u003c\/b\u003e With over \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"34\"\u003e25 years of experience\u003c\/b\u003e in surgical instrumentation and hospital materials, \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"109\"\u003ePrimis Medical\u003c\/b\u003e ensures all Zimmer orthopedic accessories are function-verified and ultrasonically cleaned prior to shipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in protective, padded packaging to ensure the precision thin-walled lumen and axial alignment remain in factory-standard condition during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Zimmer","offers":[{"title":"Default Title","offer_id":47869575659745,"sku":"ZIMM-2360-11-02","price":61.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Shopify_-_2026-01-19T103432.018.jpg?v=1768844212","url":"https:\/\/primismedical.com\/en-cn\/products\/zimmer-2360-11-02-reduction-sleeve-3-5-2-7mm-surgical-instrument","provider":"Primis Medical","version":"1.0","type":"link"}