{"product_id":"zimmer-2360-20-20-2-0mm-prosthesis-implantation-positioning-standard-cannula-orthopedic","title":"Zimmer 2360-20-20 2.0mm Prosthesis Implantation Positioning Standard Cannula Orthopedic","description":"\u003cdiv id=\"inkfrog_crosspromo_top\"\u003e\u003c\/div\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eZimmer Positioning Standard Cannula | 2.0mm ID | Orthopedic Trauma | 2360-20-20 | Reusable\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eZimmer 2360-20-20\u003c\/b\u003e is a high-precision orthopedic guide instrument engineered for the accurate spatial positioning of implants and auxiliary tools. With a \u003cb data-path-to-node=\"3\" data-index-in-node=\"158\"\u003e2.0mm internal diameter (ID)\u003c\/b\u003e, this standard cannula is a core component of Zimmer Biomet’s cannulated instrument suites, serving as a protective and directional conduit for \u003cb data-path-to-node=\"3\" data-index-in-node=\"331\"\u003e2.0mm guide wires\u003c\/b\u003e, cannulated drills, and depth gauges.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eBy providing a rigid, linear path through soft tissue and into bone, the 2360-20-20 ensures that secondary instruments follow the exact trajectory of the initial guide wire. This is critical in minimally invasive (MIS) surgery and periarticular locking plate fixations, where \"axial drift\" can lead to malpositioned screws or compromised construct stability.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Zimmer Biomet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 2360-20-20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eProduct Type:\u003c\/b\u003e Positioning Standard Cannula\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eInternal Diameter:\u003c\/b\u003e 2.0mm (Precision Cannulation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eCompatibility:\u003c\/b\u003e 2.0mm Guide Wires, Cannulated Drills, and Taps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Medical-Grade Surgical Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eConfiguration:\u003c\/b\u003e Standard Solid-Wall Cannula\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eCleaning:\u003c\/b\u003e Fully Autoclavable \/ Reusable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003ePrecision 2.0mm Lumen:\u003c\/b\u003e The internal bore is precision-ground to minimize \"instrument chatter\" and lateral deviation. This ensures that a 2.0mm drill or wire remains perfectly centered, providing a predictable and repeatable entry point for 3.5mm or 4.0mm cannulated screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eSoft Tissue Protection:\u003c\/b\u003e The smooth, polished exterior of the cannula acts as a barrier, shielding muscle, nerves, and vasculature from the rotational forces of surgical drills and taps. This is essential for \"percutaneous\" techniques where surgical visualization is limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eAnatomical Positioning Accuracy:\u003c\/b\u003e Designed to interface with Zimmer’s positioning handles and drill guides, this cannula provides the leverage needed to maintain the desired angle of attack even when engaging dense or oblique cortical bone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eStandard System Integration:\u003c\/b\u003e Fully compatible with Zimmer’s established trauma workflows, the 2360-20-20 integrates seamlessly into periarticular locking and universal small-fragment sets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eHigh-Durability Stainless Steel:\u003c\/b\u003e Forged from high-tensile stainless steel, the cannula resists bending and maintains its 2.0mm internal tolerance through years of high-torque clinical use and aggressive sterilization cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eOrthopedic Trauma:\u003c\/b\u003e Guidance for cannulated screw placement in the distal radius, humerus, or fibula.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003ePeriarticular Fixation:\u003c\/b\u003e Positioning guide wires for fixed-angle locking plates in complex joint-space fractures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eMinimally Invasive Surgery (MIS):\u003c\/b\u003e Serving as a primary access portal for percutaneous fracture reduction and fixation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eProsthesis Implantation:\u003c\/b\u003e Accurate alignment of wires for the positioning of specialized orthopedic implants and hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eUsed – Good Usable Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eMaintenance:\u003c\/b\u003e This instrument shows visible signs of professional use (minor surface scuffs or \"tray wear\" consistent with standard hospital processing), but it remains \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"168\"\u003efully functional\u003c\/b\u003e. The 2.0mm lumen is clear and unobstructed, the axial shaft is perfectly straight, and the stainless steel is free of pitting or corrosion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eProfessional Standards:\u003c\/b\u003e With over \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"34\"\u003e25 years of experience\u003c\/b\u003e in surgical instrumentation and hospital materials, \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"109\"\u003ePrimis Medical\u003c\/b\u003e ensures all Zimmer orthopedic accessories are function-verified and ultrasonically cleaned prior to shipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in protective, padded packaging to ensure the precision 2.0mm cannulation and axial alignment remain in factory-standard condition during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/305081646607-0_6cd45ad8-06d2-4e59-ae6d-1860f11ac063.jpg?v=1774973781\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Zimmer","offers":[{"title":"Default Title","offer_id":47861296398561,"sku":"ZIMM-2360-20-20","price":74.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/305081646607-0.jpg?v=1768582990","url":"https:\/\/primismedical.com\/en-cn\/products\/zimmer-2360-20-20-2-0mm-prosthesis-implantation-positioning-standard-cannula-orthopedic","provider":"Primis Medical","version":"1.0","type":"link"}