{"product_id":"zimmer-2360-205-27-periarticular-locking-plate-system-drill-bit-standard-2-7mm","title":"Zimmer 2360-205-27 Periarticular Locking Plate System Drill Bit Standard 2.7mm 8-3\/8\"","description":"\u003ch4 data-path-to-node=\"2\"\u003eZimmer Periarticular Drill Bit | 2.7mm Diameter | 8-3\/8\" Length | 2360-205-27 | Reusable\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eZimmer 2360-205-27\u003c\/b\u003e is a high-performance surgical power accessory engineered for the precise preparation of screw holes in complex periarticular fractures. With a \u003cb data-path-to-node=\"3\" data-index-in-node=\"167\"\u003e2.7mm diameter\u003c\/b\u003e, this bit is the clinical standard for creating pilot holes for \u003cb data-path-to-node=\"3\" data-index-in-node=\"246\"\u003e2.7mm locking or non-locking screws\u003c\/b\u003e, as well as gliding holes for smaller fragment constructs.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe defining characteristic of this model is its \u003cb data-path-to-node=\"4\" data-index-in-node=\"49\"\u003eextended 8-3\/8 inch (21.3 cm) overall length\u003c\/b\u003e. This extra-long profile is specifically designed to clear bulky soft tissue, navigate deep surgical corridors, and pass through tall percutaneous drill guides used in \u003cb data-path-to-node=\"4\" data-index-in-node=\"262\"\u003eMinimally Invasive Plate Osteosynthesis (MIPO)\u003c\/b\u003e. Whether addressing the proximal humerus, distal radius, or tibial plateau, this bit provides the reach necessary to maintain a perpendicular drilling trajectory without interference from the surrounding anatomy or surgical retractors.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Zimmer Biomet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eSeries:\u003c\/b\u003e Periarticular Locking Plate System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 2360-205-27\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eDiameter:\u003c\/b\u003e 2.7mm (Precision Ground)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eOverall Length:\u003c\/b\u003e 8-3\/8 Inches (21.3 cm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eInterface:\u003c\/b\u003e Standard Quick-Connect (AO-Style)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e High-Carbon Surgical Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eOperation:\u003c\/b\u003e Powered or Manual (via compatible QC handpiece)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,8,0\"\u003e\u003cb data-path-to-node=\"6,8,0\" data-index-in-node=\"0\"\u003eCleaning:\u003c\/b\u003e Fully Autoclavable \/ Reusable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eExtended Deep-Field Access:\u003c\/b\u003e The 8-3\/8\" shaft allows for \"over-the-top\" drilling in obese patients or through multi-layered muscle groups, ensuring the power driver remains well outside the sterile surgical site and does not obstruct the surgeon's line of sight.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eHigh-Efficiency Flute Geometry:\u003c\/b\u003e Precision-machined flutes facilitate rapid bone chip evacuation. This reduces friction-induced heat, protecting the surrounding bone from thermal necrosis—a critical factor for successful osseointegration in periarticular locking constructs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eStandard AO Quick-Connect:\u003c\/b\u003e The universal QC shank ensures a secure, \"no-play\" attachment to all major surgical power systems and manual T-handles, allowing for rapid intraoperative instrument changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eFixed-Angle Stability Support:\u003c\/b\u003e Calibrated specifically for Zimmer’s Periarticular Locking Plates, this bit ensures the resulting 2.7mm hole is perfectly aligned for the subsequent insertion of fixed-angle locking screws, maximizing the biomechanical strength of the final construct.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eIndustrial-Grade Forging:\u003c\/b\u003e Built to withstand the torque required for penetrating dense cortical bone at the metaphysis, the 2360-205-27 maintains its axial straightness and cutting-edge sharpness through repeated clinical use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eUpper Extremity Trauma:\u003c\/b\u003e Pilot hole preparation for 2.7mm screws in proximal humerus and distal radius plates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eLower Extremity Trauma:\u003c\/b\u003e Accessing the tibial plateau or distal fibula through deep soft-tissue envelopes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eMIPO Techniques:\u003c\/b\u003e Drilling through percutaneous tissue sleeves and remote targeting guides.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eUsed – Good Usable Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eMaintenance:\u003c\/b\u003e This instrument shows visible signs of professional use (minor surface scuffs or cosmetic \"tray wear\" consistent with standard hospital processing), but it remains \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"177\"\u003efully functional\u003c\/b\u003e. The 2.7mm cutting flutes are intact, the shaft has been verified for straightness, and the quick-connect interface is secure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eProfessional Standards:\u003c\/b\u003e With over \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"34\"\u003e25 years of experience\u003c\/b\u003e in surgical trauma and hospital materials, \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"100\"\u003ePrimis Medical\u003c\/b\u003e ensures all specialized Zimmer power accessories are function-verified and ultrasonically cleaned prior to shipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in protective, rigid packaging to ensure the extended 8-3\/8\" shaft and 2.7mm cutting tip remain in factory-standard alignment during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Shopify_-_2026-01-13T103619.728_037fc1b4-3a1e-46d5-9bfe-0337510a9d6d.jpg?v=1774977855\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Zimmer","offers":[{"title":"Default Title","offer_id":47849741320417,"sku":"ZIMM-2360-205-27","price":39.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Shopify_-_2026-01-13T103619.728.jpg?v=1768326766","url":"https:\/\/primismedical.com\/en-cn\/products\/zimmer-2360-205-27-periarticular-locking-plate-system-drill-bit-standard-2-7mm","provider":"Primis Medical","version":"1.0","type":"link"}