{"product_id":"abbott-livewire-402032-steerable-ep-catheter-large-curl","title":"Abbott Livewire 402032 Steerable EP Catheter – Large Curl, Deflectable Tip, Sterile","description":"\u003ch4 data-path-to-node=\"2\"\u003eAbbott (St. Jude Medical) Livewire Steerable EP Catheter | 6F | Large Curl | 402032\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eAbbott 402032\u003c\/b\u003e (formerly St. Jude Medical) is a high-performance diagnostic catheter engineered for complex intracardiac mapping and arrhythmia evaluation. As a centerpiece of the \u003cb data-path-to-node=\"3\" data-index-in-node=\"183\"\u003eLivewire™\u003c\/b\u003e series, this catheter is designed to provide the tactile feedback and torque response necessary for navigating difficult anatomical regions, such as the tricuspid annulus or the coronary sinus.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eFeaturing a \u003cb data-path-to-node=\"4\" data-index-in-node=\"12\"\u003e6 French (6F)\u003c\/b\u003e diameter and a \u003cb data-path-to-node=\"4\" data-index-in-node=\"41\"\u003eLarge Curl (Type X)\u003c\/b\u003e distal configuration, the 402032 offers an extended reach profile. This is particularly advantageous in dilated heart chambers or for reaching posterior atrial structures where a standard or small curl would lack sufficient contact or stability.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Abbott (St. Jude Medical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 402032\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eProduct Type:\u003c\/b\u003e Steerable Diagnostic EP Catheter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eDiameter:\u003c\/b\u003e 6 French (6F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eCurve Type:\u003c\/b\u003e Large Curl (X)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eUsable Length:\u003c\/b\u003e 115 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eElectrode Material:\u003c\/b\u003e Platinum (for high-fidelity signal acquisition)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eTip Electrode:\u003c\/b\u003e 2 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,8,0\"\u003e\u003cb data-path-to-node=\"6,8,0\" data-index-in-node=\"0\"\u003eSteering Mechanism:\u003c\/b\u003e Ergonomic Rotary Dial (Bi-directional)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,9,0\"\u003e\u003cb data-path-to-node=\"6,9,0\" data-index-in-node=\"0\"\u003eShaft Material:\u003c\/b\u003e Radiopaque Polyurethane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003ePrecision Rotary Steering:\u003c\/b\u003e The integrated rotary dial on the handle allows for fine-tuned, incremental deflection of the distal tip. This mechanical precision is critical for maintaining stable electrode-to-endocardium contact, ensuring consistent diagnostic electrograms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eSuperior Signal-to-Noise Ratio:\u003c\/b\u003e Utilizing high-purity platinum electrodes, the Livewire provides exceptionally clean signals. This high fidelity is essential for identifying fragmented potentials or localizing accessory pathways during complex EP studies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eHigh-Torque Shaft Dynamics:\u003c\/b\u003e The polyurethane shaft is engineered for 1:1 torque transmission. When the handle is rotated, the distal tip responds with minimal \"whip,\" allowing for predictable placement even through tortuous venous access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eEnhanced Fluoroscopic Visibility:\u003c\/b\u003e The radiopaque properties of the shaft and the high-density electrodes provide a clear silhouette under X-ray, reducing \"search time\" and radiation exposure for the patient and clinical staff.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eAtraumatic Design:\u003c\/b\u003e The 6F profile and flexible tip segment are designed to minimize the risk of cardiac wall perforation or vascular trauma during aggressive mapping maneuvers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eDiagnostic Electrophysiology Studies (EPS):\u003c\/b\u003e Standardized mapping of the RA, RV, and His-bundle regions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eArrhythmia Localization:\u003c\/b\u003e Identifying the origin of atrial tachycardias or ventricular ectopy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eAccessory Pathway Mapping:\u003c\/b\u003e Navigating the mitral or tricuspid valves to identify bypass tracts (e.g., Wolff-Parkinson-White syndrome).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eResearch \u0026amp; Training:\u003c\/b\u003e High-fidelity simulation of cardiac electrical pathways in veterinary or educational environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eNew \/ Never Used — Pristine Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003ePackaging:\u003c\/b\u003e Individually sealed in original manufacturer’s sterile peel-pouch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eVerification:\u003c\/b\u003e Original Abbott\/SJM labels, UDI, and lot numbers are fully intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eClinical Disclaimer:\u003c\/b\u003e \u003ci data-path-to-node=\"12,3,0\" data-index-in-node=\"21\"\u003eIf the sterile barrier is intact but the manufacturer’s expiration date has passed (e.g., 2019\/2021), this device is sold strictly for educational, training, veterinary, or non-clinical research purposes in 2026.\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in a reinforced triangular or flat-pack box to ensure the 115 cm shaft remains perfectly straight and the distal curl mechanism is not under tension during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Abbott","offers":[{"title":"Default Title","offer_id":48184323997921,"sku":"ABBO-402032","price":695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/ProductPhotos_19.png?v=1775508127","url":"https:\/\/primismedical.com\/products\/abbott-livewire-402032-steerable-ep-catheter-large-curl","provider":"Primis Medical","version":"1.0","type":"link"}