{"product_id":"arthrex-autoclavable-arthroscopy-pump-remote-control-ar-6495-for-dualwave-continuous-wave-4-systems","title":"Arthrex Autoclavable Arthroscopy Pump Remote Control AR-6495, For DualWave \u0026 Continuous Wave 4 Systems","description":"\u003ch2 data-path-to-node=\"2\"\u003eArthrex Autoclavable Pump Remote Control | AR-6495\u003c\/h2\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eArthrex AR-6495\u003c\/b\u003e is a heavy-duty, reusable fluid management accessory engineered to give the sterile surgical team absolute command over their arthroscopic environment. Operating as a direct interface with industry-standard Arthrex fluid towers, this remote brings mission-critical pump dynamics directly into the sterile field, bypassing the need for verbal instruction to unsterile circulating staff.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eBy placing immediate flow and pressure adjustments at the fingertips of the surgeon or scrub technician, the AR-6495 ensures rapid response times to intra-articular bleeding or visual clouding, maintaining chamber clarity throughout complex joint reconstructions.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eSterile-Field Fluid Autonomy:\u003c\/b\u003e Completely eliminates communication latency between the surgeon and the fluid tower, optimizing operating room efficiency and pacing during time-sensitive arthroscopic procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eDualWave™ \u0026amp; Continuous Wave™ Synergy:\u003c\/b\u003e Custom-calibrated to interface seamlessly with both the \u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"94\"\u003eArthrex DualWave™ (AR-6480)\u003c\/b\u003e and \u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"126\"\u003eContinuous Wave™ 4 (AR-6485)\u003c\/b\u003e arthroscopy pump platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eHermetically Sealed Tactile Interface:\u003c\/b\u003e The internal electronic switches are permanently sealed against moisture. This prevents fluid ingress from aggressive hand-washing or intraoperative splashes, mitigating button failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eDual-Sterilization Versatility:\u003c\/b\u003e Fully autoclavable and built to withstand repeated high-temperature steam cycles. For facilities prioritizing rapid turnover, it can also be enclosed in a standard AR-6307 sterile remote drape.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eReinforced Strain-Relief Cable:\u003c\/b\u003e The heavy-duty cord features an industrial-grade outer jacket designed to resist kinks, coil separation, and internal wire fracturing caused by tight bundling or frequent manipulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eKey Controls Available at Your Fingertips\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003ePressure Optimization:\u003c\/b\u003e Increase or decrease intra-articular pressure instantly to adapt to changing vascular or visualization demands within the joint capsule.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eLAVAGE Mode Activation:\u003c\/b\u003e Triggers a timed pressure boost to clear acute bleeding via localized tamponade, instantly re-establishing a clear view without disrupting the workflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eRINSE Flow Control:\u003c\/b\u003e Boosts the fluid flow rate to vigorously flush out troublesome bone fragments, soft tissue debris, and synovial fluid clouding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eRUN\/STOP Override:\u003c\/b\u003e Allows the sterile team to pause fluid flow instantly during scope exchanges or instrument transitions, conserving fluid and preventing accidental operating room spray.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Arthrex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eProduct Code:\u003c\/b\u003e AR-6495\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eDevice Type:\u003c\/b\u003e Fluid Management Remote Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eHousing Material:\u003c\/b\u003e High-grade, impact-resistant medical polymers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003eFormat:\u003c\/b\u003e Reusable \/ Fully Autoclavable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-path-to-node=\"10,5,0\" data-index-in-node=\"0\"\u003eCompatibility:\u003c\/b\u003e Arthrex DualWave (AR-6480) \u0026amp; Continuous Wave 4 (AR-6485)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eInterrupted Workflow Mitigation:\u003c\/b\u003e Provides a highly reliable alternative to foot pedals, which frequently slide out of the surgeon's reach or become trapped beneath fluid collection mats.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003ePer-Case Fluid Conservation:\u003c\/b\u003e The rapid RUN\/STOP response helps prevent fluid waste during transitions, extending the lifespan of the fluid bags and reducing the frequency of intraoperative bag changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eDurable Capital Asset Preservation:\u003c\/b\u003e Forged from robust, impact-resistant polymers that absorb the shock of accidental operating room drops onto hard tile surfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eStrategic Procurement:\u003c\/b\u003e Sourcing this essential workflow accessory in \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"69\"\u003e[Insert Condition]\u003c\/b\u003e allows ambulatory surgery centers (ASCs) to provide a premium, seamless interface for their sports medicine specialists while preserving operational capital.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eIdeal Applications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSports Medicine:\u003c\/b\u003e High-volume knee, shoulder, and hip arthroscopy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eAmbulatory Surgery Centers:\u003c\/b\u003e Streamlining joint debridements and repair sets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eAcademic Teaching Hospitals:\u003c\/b\u003e Allowing attending surgeons to safely monitor and adjust fluid parameters while guiding fellows through joint visualization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eQuality Assurance \u0026amp; Condition\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"8\"\u003eUsed\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\"\u003eBiomedical Validation:\u003c\/b\u003e Buttons and communication relays have been thoroughly bench-tested to ensure tactile responsiveness and 1:1 data translation to the host pump console.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\"\u003eNote to SPD:\u003c\/b\u003e When utilizing the autoclave protocol, ensure the cable is loosely coiled (minimum 6-inch diameter) to prevent long-term stress on the inner copper shielding. Do not allow other heavy metal orthopedic instruments to be stacked on top of the remote face.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Arthrex","offers":[{"title":"Default Title","offer_id":48431378530529,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/ProductPhotoEditing_1.png?v=1780329687","url":"https:\/\/primismedical.com\/products\/arthrex-autoclavable-arthroscopy-pump-remote-control-ar-6495-for-dualwave-continuous-wave-4-systems","provider":"Primis Medical","version":"1.0","type":"link"}