{"product_id":"bionx-meniscus-arrow-instrumentation-set-w-tray-cannulas-probe-trocar","title":"Bionx Meniscus Arrow Instrumentation Set w\/ Tray Cannulas Probe Trocar","description":"\u003ch4 data-path-to-node=\"2\"\u003eBionx Meniscus Arrow Instrumentation | Arthroscopic Repair Set\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eBionx Meniscus Arrow\u003c\/b\u003e system remains a foundational platform for \"all-inside\" meniscal repair, engineered for the 2026 requirements of sports medicine and arthroscopic reconstruction. This specialized instrumentation set is designed to facilitate the accurate placement of bioabsorbable Meniscus Arrows, which stabilize longitudinal tears by providing high-compression fixation.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe set is characterized by its wide array of \u003cb data-path-to-node=\"4\" data-index-in-node=\"46\"\u003eMA1100-series cannulas\u003c\/b\u003e, offering straight, curved, and multi-axial geometries. These allow the surgeon to navigate the complex curves of the femoral condyles to reach the posterior horns of both the medial and lateral menisci with minimal iatrogenic risk.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eMulti-Axial Cannula System:\u003c\/b\u003e The set includes five distinct cannula profiles (Straight, Curved, Left, Right, and Curved Shaft), ensuring the surgeon can maintain a perpendicular approach to the tear regardless of the patient's joint anatomy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eSuperior Tactile Feedback:\u003c\/b\u003e The manual delivery system (via the \u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"63\"\u003eMA1100-021 Piston\u003c\/b\u003e) provides the surgeon with a sensitive \"feel\" for tissue resistance, which is critical for ensuring the arrow has successfully bypassed the tear and anchored into the peripheral rim.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eIntegrated Access Tools:\u003c\/b\u003e Includes the \u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"38\"\u003eLinvatec\/Bionx MA1100-01 Trocar\u003c\/b\u003e, providing a robust entry path through the portal and ensuring the delicate cannulas are not damaged or bent during initial joint entry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eDiagnostic Precision:\u003c\/b\u003e The specialized \u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"38\"\u003eMeniscus Hook Probe\u003c\/b\u003e and \u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"62\"\u003eCurved Probe Shaft\u003c\/b\u003e are calibrated for tension-testing the repair intraoperatively, allowing for immediate verification of the stabilization's mechanical integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eBioabsorbable Compatibility:\u003c\/b\u003e Specifically designed for the delivery of PLA-based Meniscus Arrows, ensuring that the implants are not stressed or deformed during the insertion stroke.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eDetailed Instrument Inventory\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eCannulas (5x):\u003c\/b\u003e * \u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"17\"\u003eMA1100-05:\u003c\/b\u003e Straight with Channel and Stylet (Standard anterior access)\u003c\/p\u003e\n\u003cul data-path-to-node=\"8,0,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,1,0,0\"\u003e\u003cb data-path-to-node=\"8,0,1,0,0\" data-index-in-node=\"0\"\u003eMA1100-06:\u003c\/b\u003e Right Curve (Lateral meniscus \/ Posterior horn)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,1,1,0\"\u003e\u003cb data-path-to-node=\"8,0,1,1,0\" data-index-in-node=\"0\"\u003eMA1100-07:\u003c\/b\u003e Left Curve (Medial meniscus \/ Posterior horn)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,1,2,0\"\u003e\u003cb data-path-to-node=\"8,0,1,2,0\" data-index-in-node=\"0\"\u003eMA1100-08:\u003c\/b\u003e Curved Tip (Increased angulation for difficult corridors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,1,3,0\"\u003e\u003cb data-path-to-node=\"8,0,1,3,0\" data-index-in-node=\"0\"\u003eMA1100-09:\u003c\/b\u003e Curved Shaft (Deep-joint navigation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eDelivery \u0026amp; Access (2x):\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,1,0,0\"\u003e\u003cb data-path-to-node=\"8,1,1,0,0\" data-index-in-node=\"0\"\u003eMA1100-021:\u003c\/b\u003e Manual Piston\/Obturator (Implant deployment)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,1,1,0\"\u003e\u003cb data-path-to-node=\"8,1,1,1,0\" data-index-in-node=\"0\"\u003eMA1100-01:\u003c\/b\u003e Arthroscopic Trocar (Portal access)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eDiagnostic Probes (2x):\u003c\/b\u003e Meniscus Hook Probe and Curved Probe Shaft\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eSterilization Case:\u003c\/b\u003e Bionx-branded aluminum tray with organized layout (12\" x 10\" x 3\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eReduced Procedural Time:\u003c\/b\u003e The \"all-inside\" technique supported by this set eliminates the need for additional \"inside-out\" incisions, reducing operative time and post-operative morbidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eRemanufactured Quality:\u003c\/b\u003e Sourcing an \"Excellent Condition\" Bionx set provides high-tier orthopedic capability for sports medicine centers at a significant reduction in capital cost.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eStreamlined SPD Workflow:\u003c\/b\u003e The dedicated sterilization tray ensures all components are accounted for during reprocessing, reducing the risk of missing critical cannulas during a case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eSports Medicine:\u003c\/b\u003e Repair of vertical longitudinal meniscal tears in athletes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003ePediatric Orthopedics:\u003c\/b\u003e Minimally invasive stabilization of meniscal lesions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eJoint Preservation:\u003c\/b\u003e Maintaining meniscal function to delay the onset of osteoarthritis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"8\"\u003eUsed — Excellent Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eIntegrity:\u003c\/b\u003e All cannulas have been inspected for internal patency and lumen smoothness. The trocar tip remains sharp, and the piston mechanism operates with factory-spec resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eReprocessing Note:\u003c\/b\u003e As with all reusable orthopedic steel, this set must undergo a validated ultrasonic cleaning and high-temperature autoclave cycle prior to clinical use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bionx","offers":[{"title":"Default Title","offer_id":48359871545569,"sku":"BIONSETMENI","price":299.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/primis-auctions-dotmed-4_acb8e3d5-a1ee-4722-848e-924d67e6678f.png?v=1778529625","url":"https:\/\/primismedical.com\/products\/bionx-meniscus-arrow-instrumentation-set-w-tray-cannulas-probe-trocar","provider":"Primis Medical","version":"1.0","type":"link"}