{"product_id":"boston-scientific-m00564100-excelon-transbronchial-aspiration-needle-19g-130cm","title":"Boston Scientific M00564100 eXcelon Transbronchial Aspiration Needle - 19G, 130cm","description":"\u003ch4 data-path-to-node=\"2\"\u003eBoston Scientific eXcelon Single-Use TBNA Needle | 19 Gauge | M00564100\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe Boston Scientific eXcelon M00564100 is a premium, single-use transbronchial aspiration needle (TBNA) engineered to deliver high-precision submucosal tissue sampling during diagnostic bronchoscopy procedures. Featuring a heavy-duty 19-gauge biopsy needle, this specialized pulmonology instrument is purpose-built to capture high-yield cytological and histological samples from carinal, paratracheal, and hilar lesions within the bronchial tree.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe eXcelon system is highly favored by pulmonologists for navigating tortuous anatomical pathways, allowing clinicians to securely access deep-tissue structures where traditional biopsy forceps cannot effectively reach.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eAccidental Deployment Button Lock:\u003c\/b\u003e Outfitted with an integrated mechanical sliding button-lock system designed to prevent accidental needle extrusion during initial catheter advancement, safeguarding fragile endoscope working channels from costly inner-liner puncture damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eFused Hub Integrity:\u003c\/b\u003e Engineered with a specialized fused hub-to-needle interface profile that resists physical needle detachment, bending, or structural kinking during high-pressure, multi-pass aspiration maneuvers in dense lesions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eClear Optical Catheter Wall:\u003c\/b\u003e Built with entirely transparent proximal catheter tubing, allowing the surgical team to visually confirm immediate blood flash or successful cytological fluid return the instant mechanical suction is engaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eComplete Procedure Kit Inclusions:\u003c\/b\u003e Factory bundled with a high-capacity 20ml locking syringe, enabling easy single-handed suction stabilization without straining internal clinical workflows or requiring secondary aspiration hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Boston Scientific\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eProduct Line:\u003c\/b\u003e eXcelon Transbronchial Aspiration Needles (TBNA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eModel \/ Order Number:\u003c\/b\u003e M00564100 (Packaged commercial equivalent to catalog style M00564101)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eNeedle Size:\u003c\/b\u003e 19 Gauge (1.1 mm Outer Diameter)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eNeedle Working Length:\u003c\/b\u003e 15 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eCatheter Overall Length:\u003c\/b\u003e 130 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eSheath Outer Diameter:\u003c\/b\u003e 1.8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,7,0\"\u003e\u003cb data-path-to-node=\"8,7,0\" data-index-in-node=\"0\"\u003eSterilization Matrix:\u003c\/b\u003e Sterile using Ethylene Oxide (EO Gas) processes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,8,0\"\u003e\u003cb data-path-to-node=\"8,8,0\" data-index-in-node=\"0\"\u003eUsage Profile:\u003c\/b\u003e Single-Use Disposable \/ Intended for Immediate Clinical Application\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpiration: \u003c\/strong\u003e2026-12-05\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical and Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eHigh-Yield Histological Sampling:\u003c\/b\u003e The wide 19-gauge core profile maximizes core tissue collection during standard staging or diagnostic sweeps, frequently reducing the total number of needle passes required to achieve an accurate pathologic diagnosis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eGuaranteed Factory Sharpness:\u003c\/b\u003e Packaged as a sterile, single-use instrument to ensure 100 percent penetration efficiency through tough bronchial walls, eliminating the rapid dulling and cross-contamination risks associated with reprocessed biopsy devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eSubstantial Procurement Value:\u003c\/b\u003e Sourcing this genuine Boston Scientific surgical overstock allows hospital procurement teams, endoscopy centers, and outpatient pulmonology clinics to maintain a robust inventory of premium diagnostic consumables at a significant savings compared to standard OEM contract list pricing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eDiagnostic Pulmonology:\u003c\/b\u003e Targeted transbronchial needle aspiration of mediastinal and hilar lymph nodes for lung cancer staging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eEndobronchial Ultrasound (EBUS):\u003c\/b\u003e Blind or ultrasound-assisted submucosal biopsy of peribronchial masses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eInfectious Disease Tracking:\u003c\/b\u003e Sampling deep pulmonary lesions to diagnose complex fungal, tuberculous, or granulomatous diseases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCondition and Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e Brand New, Unused Surgical Surplus Stock.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eSterility Track:\u003c\/b\u003e Every aspiration needle is individually enclosed within its original, untampered medical-grade factory peel-pouch to preserve sterile barrier validation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Boston Scientific","offers":[{"title":"Default Title","offer_id":48464579133665,"sku":null,"price":197.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/HX55144_M00564100.png?v=1781116150","url":"https:\/\/primismedical.com\/products\/boston-scientific-m00564100-excelon-transbronchial-aspiration-needle-19g-130cm","provider":"Primis Medical","version":"1.0","type":"link"}