{"product_id":"lumenis-ultrapulse-surgitouch-ga-0000540-co2-surgical-system-2010","title":"Lumenis UltraPulse SurgiTouch GA-0000540 CO2 Surgical System 2010","description":"\u003ch4 data-path-to-node=\"2\"\u003eLumenis UltraPulse® SurgiTouch™ | CO2 Surgical Laser | GA-0000540\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eLumenis UltraPulse®\u003c\/b\u003e is widely considered the gold standard in CO2 laser technology, engineered to meet the highest demands of both surgical and aesthetic specialties. This system is distinguished by its ability to deliver high peak power in very short pulse durations, facilitating \u003cb data-path-to-node=\"3\" data-index-in-node=\"286\"\u003echar-free ablation\u003c\/b\u003e and precise tissue incision with minimal thermal spread.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eEquipped with the \u003cb data-path-to-node=\"4\" data-index-in-node=\"18\"\u003eSurgiTouch™\u003c\/b\u003e automation software, the unit provides an intuitive, menu-driven interface that optimizes laser parameters for specific clinical applications, ensuring consistent and reproducible results across various tissue types.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eUltraPulse® Technology:\u003c\/b\u003e Capable of delivering up to 225 mJ per pulse. This high-energy, short-pulse delivery allows the laser to vaporize tissue faster than the skin can conduct heat, significantly reducing the risk of peripheral thermal damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eSurgiTouch™ Digital Interface:\u003c\/b\u003e The integrated touchscreen features a comprehensive database of pre-set protocols. This automation assists the clinician in selecting the optimal scanning pattern, depth, and energy for specific procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eArticulated Delivery Arm:\u003c\/b\u003e The high-precision, balanced arm ensures effortless maneuverability and beam stability, essential for delicate microsurgical and periorbital applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eVersatile Operating Modes:\u003c\/b\u003e Supports \u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"36\"\u003eContinuous Wave (CW)\u003c\/b\u003e for traditional cutting\/coagulation and \u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"97\"\u003eUltraPulse\u003c\/b\u003e modes for advanced fractional resurfacing or deep tissue ablation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eExceptional Depth Control:\u003c\/b\u003e Provides the surgeon with the ability to precisely control the \"depth of impact,\" which is critical when working near vital structures in ENT or neurosurgical cases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Lumenis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e UltraPulse® SurgiTouch™ (GA-0000540)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eDate of Manufacture:\u003c\/b\u003e December 2010\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eWavelength:\u003c\/b\u003e 10.6 µm (CO2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eElectrical:\u003c\/b\u003e 100–120V, 50\/60 Hz, 20A (Single Phase)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eSerial Number:\u003c\/b\u003e 496\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003ePlatform:\u003c\/b\u003e Cart-based mobile system with integrated storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eOptimized Patient Outcomes:\u003c\/b\u003e Reduced thermal damage leads to faster healing times, less post-operative edema, and a lower incidence of scarring compared to standard CO2 lasers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eBroad Procedural Scope:\u003c\/b\u003e One of the few CO2 systems capable of spanning the entire clinical spectrum—from deep-plane surgical incisions in ENT to high-end fractional skin resurfacing in aesthetics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eProven Reliability:\u003c\/b\u003e The 2010 UltraPulse® chassis is renowned for its robust internal optics and reliable RF-excited laser source, making it a favorite for biomedical refurbishment and long-term facility use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eStrategic Procurement:\u003c\/b\u003e Acquiring this \"Powers-On\" unit provides a high-tier surgical platform at a significant reduction in capital cost, ideal for practices with existing service contracts or in-house laser technicians.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eAesthetic Dermatology:\u003c\/b\u003e Fractional resurfacing, scar revision, and deep-wrinkle ablation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eOtolaryngology (ENT):\u003c\/b\u003e LAUP (Laser-Assisted Uvulopalatoplasty), stapedotomy, and vocal cord lesion removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eGynecology:\u003c\/b\u003e Treatment of endometriosis and cervical dysplasia.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eGeneral Surgery:\u003c\/b\u003e Precise, bloodless incisions and soft tissue excision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"8\"\u003eUsed — Powers On.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFunctional Note:\u003c\/b\u003e The system initializes successfully and the touchscreen interface is responsive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eLaser Output:\u003c\/b\u003e \u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"14\"\u003eNOT TESTED.\u003c\/b\u003e Verification of wattage, beam alignment, and pulse consistency has not been performed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eBiomedical Note:\u003c\/b\u003e As a Class IV laser, this unit must be inspected, calibrated, and certified for safety by a qualified laser service technician prior to any clinical or patient use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumenis","offers":[{"title":"Default Title","offer_id":48362219765985,"sku":"LUMGA0000540","price":12325.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/primis-auctions-dotmed_fbff6a22-7092-4bab-b8e3-45062eda708f.png?v=1778600496","url":"https:\/\/primismedical.com\/products\/lumenis-ultrapulse-surgitouch-ga-0000540-co2-surgical-system-2010","provider":"Primis Medical","version":"1.0","type":"link"}