{"product_id":"pajunk-sonoplex-ii-001287-74-echogenic-nerve-block-needle-22g-x-50mm-facet-s-tip","title":"Pajunk SonoPlex II 001287-74 Echogenic Nerve Block Needle - 22G x 50mm, Facet S Tip BX\/10","description":"\u003ch4 data-path-to-node=\"2\"\u003ePajunk SonoPlex® II | Dual Guidance | 22G x 50 mm | 001287-74\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003ePajunk SonoPlex® II (001287-74)\u003c\/b\u003e represents the 2026 gold standard for Peripheral Nerve Blocks (PNB). Engineered for \u003cb data-path-to-node=\"3\" data-index-in-node=\"120\"\u003eDual Guidance\u003c\/b\u003e, this needle allows clinicians to simultaneously utilize ultrasound visualization and nerve stimulation. By integrating laser-embossed \u003cb data-path-to-node=\"3\" data-index-in-node=\"269\"\u003eCornerstone Reflectors\u003c\/b\u003e, Pajunk has solved the clinical challenge of \"needle dropout,\" ensuring the shaft and tip remain highly visible even at the steep insertion angles required for deep-seated neural structures.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eFeaturing the \u003cb data-path-to-node=\"4\" data-index-in-node=\"14\"\u003eFacet S tip\u003c\/b\u003e and \u003cb data-path-to-node=\"4\" data-index-in-node=\"30\"\u003eNanoLine® coating\u003c\/b\u003e, the SonoPlex II provides a superior tactile \"pop\" while maintaining a smooth, atraumatic glide through various tissue layers.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eCornerstone Reflectors:\u003c\/b\u003e Laser-etched graduations around the full 360° of the needle ensure high echogenicity. These reflectors are specifically engineered to return ultrasound waves to the transducer even at steep angles (up to 60° or 70°).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eFacet S Tip Geometry:\u003c\/b\u003e A hybrid design that combines the sharpness of a facet needle for effortless skin entry with a specialized bevel angle that enhances tactile feedback and provides a clear \"click\" when penetrating the fascia.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eNanoLine® Thin-Film Coating:\u003c\/b\u003e An ultra-thin polymer coating that provides exceptional insulation for precise nerve stimulation while reducing friction during insertion, ensuring the needle doesn't \"drag\" on the tissue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eDual Guidance Integration:\u003c\/b\u003e Includes an integrated stimulation cable and injection tubing, allowing for a seamless transition between ultrasound identification and electrical nerve localization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eRemovable Stimulation Cable:\u003c\/b\u003e Features a standardized connector compatible with all major nerve stimulators, allowing for easy disconnection if stimulation is no longer required during the block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Pajunk (Made in Germany)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eProduct Code:\u003c\/b\u003e 001287-74 (SonoPlex® II)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eGauge:\u003c\/b\u003e 22G\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eLength:\u003c\/b\u003e 50 mm (2 inches)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eTip Style:\u003c\/b\u003e Facet S (Echogenic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eCoating:\u003c\/b\u003e NanoLine® (Insulated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eConnection:\u003c\/b\u003e Integrated Tubing and Stimulation Lead\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,7,0\"\u003e\u003cb data-path-to-node=\"8,7,0\" data-index-in-node=\"0\"\u003eQuantity:\u003c\/b\u003e Box of 10 individual needles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eIncreased Safety:\u003c\/b\u003e Dual Guidance reduces the risk of accidental intraneural injection by providing two independent methods of verifying needle-to-nerve proximity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eReduced Procedure Time:\u003c\/b\u003e Superior echogenicity at all angles minimizes the need for \"probing\" or transducer adjustments, allowing for faster block placement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eInstitutional Standardization:\u003c\/b\u003e Sourcing genuine Pajunk overstock allows high-volume anesthesia departments to utilize the most advanced echogenic technology while maintaining strict budgetary controls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eUpper Extremity Blocks:\u003c\/b\u003e Interscalene, supraclavicular, and axillary blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eLower Extremity Blocks:\u003c\/b\u003e Femoral and saphenous nerve blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eChronic Pain Management:\u003c\/b\u003e Targeted diagnostic injections and therapeutic blocks under ultrasound.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"8\"\u003eNEW — Genuine Pajunk Overstock.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eExpiration Date:\u003c\/b\u003e Typically May 2030 (05-2030).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003ePackaging:\u003c\/b\u003e Original OEM packaging with factory seals 100% intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eVerification:\u003c\/b\u003e Guaranteed authentic Pajunk instrumentation, stored in a climate-controlled environment to preserve the integrity of the NanoLine® coating and sterile tubing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pajunk","offers":[{"title":"Default Title","offer_id":48283250524385,"sku":null,"price":219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/ProductPhotos-2026-05-05T105633.720.png?v=1778000363","url":"https:\/\/primismedical.com\/products\/pajunk-sonoplex-ii-001287-74-echogenic-nerve-block-needle-22g-x-50mm-facet-s-tip","provider":"Primis Medical","version":"1.0","type":"link"}