{"product_id":"stryker-5400-31-core-oscillating-saw","title":"Stryker 5400-31 CORE Oscillating Saw","description":"\u003ch4 data-path-to-node=\"2\"\u003eStryker CORE Oscillating Saw | Slim Handpiece | 5400-31\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eStryker 5400-31\u003c\/b\u003e is a high-performance powered surgical attachment engineered for precision osteotomies and bone resection. As a core component of the \u003cb data-path-to-node=\"3\" data-index-in-node=\"154\"\u003eStryker CORE (Consolidated Operating Room Equipment)\u003c\/b\u003e ecosystem, this oscillating saw handpiece is designed to provide maximum cutting efficiency with minimal vibration. Its slim, cylindrical \"pen-grip\" profile is specifically optimized for deep-access procedures and small-fragment orthopedic trauma where traditional, bulkier saws may obstruct the surgeon's line of sight.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe 5400-31 utilizes a high-frequency oscillation arc to achieve clean, burr-free bone cuts. When integrated with the CORE Console, it benefits from advanced digital torque management, ensuring consistent blade speed even under heavy cortical load.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Stryker\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eSystem Platform:\u003c\/b\u003e CORE (Consolidated Operating Room Equipment)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 5400-31\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eProduct Type:\u003c\/b\u003e Oscillating Saw Attachment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eDrive Mechanism:\u003c\/b\u003e Electric (via CORE Universal Driver)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eBody Style:\u003c\/b\u003e Slim Cylindrical \/ Ergonomic Pen-Grip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eBlade Interface:\u003c\/b\u003e Quick-Connect Locking Hub\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Anodized Aluminum and Surgical-Grade Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,8,0\"\u003e\u003cb data-path-to-node=\"6,8,0\" data-index-in-node=\"0\"\u003eQuantity:\u003c\/b\u003e 1 Each\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eOptimized Power-to-Weight Ratio:\u003c\/b\u003e Despite its slender profile, the 5400-31 delivers the high torque necessary for diaphyseal bone cuts. The reduced weight significantly lowers surgeon hand fatigue during prolonged reconstructive procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eIntegrated CORE Intelligence:\u003c\/b\u003e When connected to the CORE system, the handpiece communicates with the console to optimize power output, preventing overheating and ensuring the blade maintains its duty cycle under variable bone densities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eSuperior Maneuverability:\u003c\/b\u003e The cylindrical design allows for a 360° grip, enabling the surgeon to approach osteotomies from multiple angles in confined anatomical corridors, such as the midface, hand, or foot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eQuick-Load Blade Hub:\u003c\/b\u003e The locking mechanism is designed for rapid, one-handed blade exchanges. It is compatible with a wide array of Stryker oscillating blades, ranging from fine micro-blades to standard orthopedic profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eVibration Dampening:\u003c\/b\u003e Engineered with internal counter-balancing, the 5400-31 minimizes the transfer of vibration to the surgeon's hand, enhancing tactile feedback and improving the accuracy of the bone cut.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eOrthopedic Trauma:\u003c\/b\u003e Fixation of small fragment fractures in the extremities (hand, foot, wrist, and ankle).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eOral \u0026amp; Maxillofacial Surgery:\u003c\/b\u003e Performing osteotomies for reconstructive or orthognathic procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eNeurosurgery:\u003c\/b\u003e Specialized cranial flap creation or spinal decompression where precise bone removal is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003ePodiatric Surgery:\u003c\/b\u003e Bunionectomies and midfoot fusions requiring clean, perpendicular bone surfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eExcellent Pre-owned Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eIntegrity:\u003c\/b\u003e The drive interface is clean and free of debris; the internal bearings rotate smoothly without audible grinding or heat buildup. The blade locking hub engages securely with a positive \"click.\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eMaintenance Requirement:\u003c\/b\u003e This is a \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"35\"\u003ereusable powered instrument\u003c\/b\u003e. It must be cleaned, lubricated, and sterilized (typically via pre-vacuum steam autoclave) according to hospital protocols and Stryker’s Instructions for Use (IFU) before clinical deployment in 2026.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eProfessional Standards:\u003c\/b\u003e With over \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"34\"\u003e25 years of experience\u003c\/b\u003e in surgical power tools, \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"82\"\u003ePrimis Medical\u003c\/b\u003e ensures all Stryker CORE handpieces are bench-tested for RPM consistency and mechanical alignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in specialized anti-static and shock-absorbent packaging to protect the internal precision motor and electronic coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay-1_71790e3b-fe48-48b6-ad9b-ad2c4a22bafe.png?v=1775499252\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":48183999430881,"sku":"STRY540031","price":213.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay-1_26f7fa84-112e-4ce9-816f-5123e16f62d4.png?v=1775499196","url":"https:\/\/primismedical.com\/products\/stryker-5400-31-core-oscillating-saw","provider":"Primis Medical","version":"1.0","type":"link"}