{"product_id":"stryker-5400-99-core-universal-driver-dual-trigger-handpiece-5-3-8","title":"Stryker 5400-099-000 CORE Universal Driver Dual-Trigger Handpiece 5-3\/8\"","description":"\u003ch4 data-path-to-node=\"2\"\u003eStryker CORE Universal Driver | Dual-Trigger | 5-3\/8\" | 5400-099-000\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eStryker 5400-099-000\u003c\/b\u003e is a high-performance electric powered instrument designed for the demanding requirements of orthopedic, podiatric, and cranio-maxillofacial surgery. As part of the \u003cb data-path-to-node=\"3\" data-index-in-node=\"190\"\u003eCORE (Consolidated Operating Room Equipment)\u003c\/b\u003e ecosystem, this universal driver delivers a balanced combination of high torque and high speed in a compact, \u003cb data-path-to-node=\"3\" data-index-in-node=\"344\"\u003e5-3\/8 inch\u003c\/b\u003e ergonomic chassis.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003edual-trigger configuration\u003c\/b\u003e provides independent control over forward, reverse, and oscillate modes, allowing for seamless transitions during drilling, reaming, or wire driving. This handpiece is the industry standard for surgeons who require a lightweight tool that does not sacrifice power for precision.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Stryker\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 5400-099-000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eSeries:\u003c\/b\u003e CORE (Consolidated Operating Room Equipment)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eControl:\u003c\/b\u003e Dual-Trigger (Variable Speed \/ Directional Control)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eOverall Length:\u003c\/b\u003e 5-3\/8 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003ePower Source:\u003c\/b\u003e Electric (CORE \/ CORE 2 Consoles)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eAttachment Interface:\u003c\/b\u003e Stryker Quick-Connect (Compatible with 5400-series attachments)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eOptimized Power-to-Weight Ratio:\u003c\/b\u003e At just 5-3\/8 inches, this driver minimizes hand fatigue during lengthy procedures while providing the high-torque output necessary for cortical bone penetration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eIntelligent Dual-Trigger Ergonomics:\u003c\/b\u003e The dual-trigger setup allows for instantaneous toggling between modes. The primary trigger controls speed, while the secondary trigger manages directional changes, ensuring the surgeon never has to break focus from the surgical field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eMultispecialty Versatility:\u003c\/b\u003e This universal driver is compatible with an extensive library of Stryker attachments, including:\u003c\/p\u003e\n\u003cul data-path-to-node=\"8,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,1,0,0\"\u003e\u003cb data-path-to-node=\"8,2,1,0,0\" data-index-in-node=\"0\"\u003eWire \u0026amp; Pin Collets\u003c\/b\u003e (for K-wire fixation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,1,1,0\"\u003e\u003cb data-path-to-node=\"8,2,1,1,0\" data-index-in-node=\"0\"\u003eAO\/Trinkle Drill Chucks\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,1,2,0\"\u003e\u003cb data-path-to-node=\"8,2,1,2,0\" data-index-in-node=\"0\"\u003eKeyed\/Keyless Jacob’s Chucks\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,1,3,0\"\u003e\u003cb data-path-to-node=\"8,2,1,3,0\" data-index-in-node=\"0\"\u003eSagittal \u0026amp; Reciprocating Saw Attachments\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eQuiet, Low-Vibration Operation:\u003c\/b\u003e The CORE electric motor is engineered for smooth energy delivery, reducing the tactile \"chatter\" often associated with pneumatic tools and enhancing the surgeon’s tactile feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eIntegrated Irrigation Compatibility:\u003c\/b\u003e Designed to work with Stryker’s integrated irrigation clips to prevent thermal necrosis during high-speed drilling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eOrthopedic Trauma:\u003c\/b\u003e Fixation of small and large fragment fractures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eSports Medicine:\u003c\/b\u003e ACL\/PCL reconstruction and joint debridement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003ePodiatry:\u003c\/b\u003e Osteotomies and fusion procedures of the forefoot and midfoot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eENT \u0026amp; Neuro:\u003c\/b\u003e Cranial flap procedures and skull base surgery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eUsed — Operational Standards Met.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eMaintenance:\u003c\/b\u003e These handpieces have been clinically used and show visible cosmetic wear consistent with standard hospital sterilization and usage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003ePerformance Testing:\u003c\/b\u003e Each unit has been bench-tested to ensure the motor, triggers, and attachment locking mechanisms meet 2026 operational standards for speed and torque.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eSterilization Note:\u003c\/b\u003e This device is provided \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"44\"\u003eNON-STERILE\u003c\/b\u003e. It must be cleaned and sterilized via validated steam autoclave protocols following Stryker’s specific Instructions for Use (IFU) prior to clinical application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in protective, shock-absorbent packaging to ensure the internal motor and electronic sensors remain calibrated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Screenshot_2025-07-21_122057_1753122075687e851b7f1726829.png?v=1753122077\" alt=\"\" width=\"300\" height=\"385\"\u003e\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":46572325306593,"sku":"STRY-5400-099-000","price":536.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/ebay-2025-06-20t155315924.jpg?v=1752130659","url":"https:\/\/primismedical.com\/products\/stryker-5400-99-core-universal-driver-dual-trigger-handpiece-5-3-8","provider":"Primis Medical","version":"1.0","type":"link"}