{"product_id":"stryker-6400-034-000-remb-electric-sagittal-saw-handpiece-5-3-8","title":"Stryker 6400-034-000 RemB Electric Sagittal Saw Handpiece 5-3\/8\"","description":"\u003ch4 data-path-to-node=\"2\"\u003eStryker RemB Electric Sagittal Saw | 5-3\/8\" | 6400-034-000\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eStryker 6400-034-000\u003c\/b\u003e is a high-performance electric powered instrument engineered for the specialized demands of small-bone surgery, including hand, foot, and maxillofacial procedures. As part of the \u003cb data-path-to-node=\"3\" data-index-in-node=\"204\"\u003eRemB (Remote Body)\u003c\/b\u003e series, this sagittal saw provides a lightweight, ergonomic solution that delivers high-frequency oscillation with the high-torque stability required for dense cortical bone.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eMeasuring just \u003cb data-path-to-node=\"4\" data-index-in-node=\"15\"\u003e5-3\/8 inches\u003c\/b\u003e, this handpiece is designed to provide maximum maneuverability in tight surgical corridors. Its low-vibration electric motor is calibrated to reduce tactile noise, providing the surgeon with superior tactile feedback during delicate osteotomies or joint reconstructions.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Stryker\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 6400-034-000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eSeries:\u003c\/b\u003e RemB (Electric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eOverall Length:\u003c\/b\u003e 5-3\/8 inches (13.7 cm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003ePower Source:\u003c\/b\u003e Electric (CORE \/ CORE 2 Console)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eCutting Action:\u003c\/b\u003e Sagittal (Side-to-Side) Oscillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eBlade Interface:\u003c\/b\u003e Stryker Quick-Connect (RemB\/TPS compatible)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eOptimized Micro-Precision:\u003c\/b\u003e The RemB series is specifically tuned for precision. Its high-speed oscillation allows for \"feather-touch\" cutting, which is essential for preserving bone integrity in pediatric or small-fragment orthopedic trauma.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eErgonomic \"Pencil-Grip\" Handling:\u003c\/b\u003e The 5-3\/8 inch length and slim profile allow the surgeon to hold the instrument like a pen, facilitating exceptionally accurate angular cuts that are difficult to achieve with larger, pistol-grip saws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eLow-Vibration Motor Technology:\u003c\/b\u003e Engineered to minimize harmonic resonance, the electric motor reduces the \"chatter\" often felt in pneumatic alternatives. This leads to smoother osteotomies and less hand fatigue during long reconstructive cases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eInstantaneous Start\/Stop:\u003c\/b\u003e When paired with the CORE console, the handpiece offers nearly immediate blade acceleration and braking, providing the surgeon with absolute control over the depth and duration of each cut.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eDurable Surgical Construction:\u003c\/b\u003e Forged from high-grade stainless steel and specialized composites, the 6400-034-000 is built to withstand the rigors of repeated steam sterilization without compromising electronic calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eHand \u0026amp; Wrist Surgery:\u003c\/b\u003e Phalangeal and metacarpal osteotomies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003ePodiatry:\u003c\/b\u003e Bunions (Hallux Valgus) corrections and midfoot fusions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eMaxillofacial Surgery:\u003c\/b\u003e Precision mandibular or maxillary cuts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eOrthopedic Trauma:\u003c\/b\u003e Stabilization and resizing of small bone grafts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eUsed — Operational Standards Met.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eMaintenance:\u003c\/b\u003e This instrument has been previously utilized in a clinical environment and shows cosmetic wear (scratches\/discoloration) consistent with professional use and hospital-grade sterilization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003ePerformance Testing:\u003c\/b\u003e The unit has been bench-tested to ensure motor RPM, oscillation frequency, and blade-locking mechanisms meet 2026 operational standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eSterilization Note:\u003c\/b\u003e This device is provided \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"44\"\u003eNON-STERILE\u003c\/b\u003e. It must be thoroughly cleaned and sterilized via validated steam autoclave protocols in accordance with your facility's guidelines and Stryker's Instructions for Use (IFU).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in shock-absorbent packaging to protect the internal electric drive and sensor components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Screenshot_2025-07-18_112240_1752859441687a8331e81155819.png?v=1752859443\" alt=\"\" width=\"300\" height=\"86\"\u003e\u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":46572322521313,"sku":"STRY-6400-034-000","price":312.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/ebay-2025-06-19t152225739.jpg?v=1752130578","url":"https:\/\/primismedical.com\/products\/stryker-6400-034-000-remb-electric-sagittal-saw-handpiece-5-3-8","provider":"Primis Medical","version":"1.0","type":"link"}