{"product_id":"stryker-8215-000-000-system-8-large-battery-pack-w-over-temp-history-106-uses","title":"Stryker 8215-000-000 System 8 Large Battery Pack w\/ Over Temp History 106 Uses","description":"\u003ch2\u003eStryker 8215-000-000 System 8 Large Battery Pack w\/ Over Temp History 106 Uses\u003c\/h2\u003e\n\u003cp\u003e• Model: 8215-000-000 (Stryker)\u003cbr\u003e• Uses: 106\u003cbr\u003e• Overtemp: 2\u003cbr\u003e• Time Overtemp: 93 Minutes\u003cbr\u003e\u003cbr\u003eThese surgical instruments have been previously used and show visible signs of wear consistent with their prior usage. Despite these signs, they remain in a usable condition, suitable for continued medical procedures.\u003c\/p\u003e\n\u003cp data-start=\"44\" data-end=\"158\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eThe \u003cstrong data-start=\"4\" data-end=\"48\"\u003e8215‑000‑000 System 8 Large Battery Pack\u003c\/strong\u003e is Stryker’s high-capacity lithium-ion unit, designed specifically for use with System 8 cordless surgical handpieces—including drills, saws, and drivers. Measuring about 84 × 71 × 76 mm and weighing approximately 0.42 kg (0.93 lb), it delivers around 21.8 Wh of power (2200 mAh at 9.9 V)\u003c\/span\u003e \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eThis sizable energy reserve typically supports 20 minutes or more of continuous use, depending on the procedure and tool load.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"160\" data-end=\"274\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eAccording to documented service data, this particular pack has been used \u003cstrong data-start=\"73\" data-end=\"86\"\u003e106 times\u003c\/strong\u003e, with \u003cstrong data-start=\"93\" data-end=\"142\"\u003e2 over‑temperature events totaling 93 minutes\u003c\/strong\u003e of thermal exceedance.\u003c\/span\u003e \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eOver‑temperature logs occur when internal sensors detect heat exceeding safe thresholds. Although the unit remains rated as functional, repeated thermal stress could impact future performance and capacity—knowing this history helps gauge remaining service life and potential replacement timelines.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"160\" data-end=\"274\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Screenshot_2025-07-22_095839_1753199929687fb539dab5d3313.png?v=1753199931\" alt=\"\" width=\"300\" height=\"352\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"160\" data-end=\"274\"\u003e \u003c\/p\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":46484537934049,"sku":"STRY-8215-106","price":193.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/ebay-2025-05-05t143005608.jpg?v=1752123784","url":"https:\/\/primismedical.com\/products\/stryker-8215-000-000-system-8-large-battery-pack-w-over-temp-history-106-uses","provider":"Primis Medical","version":"1.0","type":"link"}