{"product_id":"stryker-multigen-medical-equipment-console-w-cables-powers-on","title":"Stryker MultiGen Medical Equipment Console w\/ Cables Powers On","description":"\u003ch4 data-path-to-node=\"2\"\u003eStryker MultiGen® RF Generator | Interventional Spine System\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eStryker MultiGen®\u003c\/b\u003e is a high-performance radiofrequency generator engineered for the 2026 standards of interventional pain management. This system is distinguished by its ability to perform up to \u003cb data-path-to-node=\"3\" data-index-in-node=\"199\"\u003efour simultaneous independent lesions\u003c\/b\u003e, significantly reducing procedural time for complex spinal denervations such as medial branch blocks and sacroiliac joint (SIJ) treatments.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eEquipped with an intuitive touchscreen interface, the MultiGen provides the clinician with total control over sensory and motor stimulation, impedance monitoring, and lesion parameters, ensuring a high level of accuracy and patient safety during every thermal or pulsed RF procedure.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eIndependent Multichannel Capability:\u003c\/b\u003e Allows for the simultaneous treatment of up to four levels. Each channel is monitored independently for impedance and temperature, providing tailored energy delivery to each specific anatomical site.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eIntelligent Touchscreen Interface:\u003c\/b\u003e The high-resolution display provides real-time data for all active channels, including temperature, time, and power (voltage\/current), alongside clear sensory and motor stimulation protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eVersatile Procedural Modes:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"6,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,1,0,0\"\u003e\u003cb data-path-to-node=\"6,2,1,0,0\" data-index-in-node=\"0\"\u003eThermal RF:\u003c\/b\u003e For standardized, high-temperature neurotomy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,1,1,0\"\u003e\u003cb data-path-to-node=\"6,2,1,1,0\" data-index-in-node=\"0\"\u003ePulsed RF:\u003c\/b\u003e For non-ablative, neuromodulatory treatments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,1,2,0\"\u003e\u003cb data-path-to-node=\"6,2,1,2,0\" data-index-in-node=\"0\"\u003eSensory\/Motor Stimulation:\u003c\/b\u003e Precise frequency and voltage control to verify needle placement and avoid proximity to motor nerves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eIntegrated Safety Protocols:\u003c\/b\u003e Automatic \"Stop\" triggers for high-impedance or over-temperature events, protecting against unintended tissue damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eMonopolar \u0026amp; Bipolar Support:\u003c\/b\u003e Compatible with a wide range of interventional spine needles and electrodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications \u0026amp; Included Components\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Stryker Instruments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e MultiGen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eSerial Number:\u003c\/b\u003e LES5707\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003ePower:\u003c\/b\u003e 100V–120V \/ 230V Universal Input (200VA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eFuse:\u003c\/b\u003e 2 x T2.5A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eDuty Cycle:\u003c\/b\u003e Designed for extended clinical use (999s on \/ 90s off)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eIncluded Cables:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8,6,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,1,0,0\"\u003e\u003cb data-path-to-node=\"8,6,1,0,0\" data-index-in-node=\"0\"\u003e1x 0406-850-200:\u003c\/b\u003e Monopolar Return Electrode (Grounding) Cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,1,1,0\"\u003e\u003cb data-path-to-node=\"8,6,1,1,0\" data-index-in-node=\"0\"\u003e2x 0406-900-100:\u003c\/b\u003e RF Electrode Cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,7,0\"\u003e\u003cb data-path-to-node=\"8,7,0\" data-index-in-node=\"0\"\u003eControls:\u003c\/b\u003e Blue Stryker Foot-Pedal activation switch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eOptimized Procedure Volume:\u003c\/b\u003e By treating multiple levels simultaneously, clinical throughput is increased, and patient \"table time\" is significantly reduced compared to single-channel legacy generators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eEnhanced Diagnostic Accuracy:\u003c\/b\u003e The advanced sensory\/motor stimulation settings allow for refined needle positioning, which is critical in the cervical and lumbar regions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eRobust Data Summary:\u003c\/b\u003e Provides a post-procedural summary screen to verify lesion times and temperatures for accurate medical record documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eStrategic Value:\u003c\/b\u003e Acquiring this \"Powers-On\" MultiGen console allows specialized clinics to maintain high-tier RF capabilities or add secondary procedure rooms at a fraction of the cost of new-generation platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eFacet Denervation:\u003c\/b\u003e Medial branch radiofrequency neurotomy (Cervical, Thoracic, Lumbar).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eSacroiliac Joint (SIJ):\u003c\/b\u003e Large-volume denervation utilizing multichannel inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eTrigeminal Neuralgia:\u003c\/b\u003e Precision controlled thermal lesioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003ePulsed RF:\u003c\/b\u003e Management of chronic radiculopathy or peripheral nerve pain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"8\"\u003eUsed — Great Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFunctional Note:\u003c\/b\u003e The console has been bench-tested and \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"55\"\u003epowers on\u003c\/b\u003e successfully. The touchscreen is responsive and the system initializes through its boot sequence to the main control screen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eCosmetic Note:\u003c\/b\u003e Shows minimal clinical wear. The housing is robust and all ports\/connectors are clean and intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eBiomedical Note:\u003c\/b\u003e As an electrosurgical device, this generator must undergo a full calibration and electrical safety inspection by a certified biomedical technician before clinical use to ensure accurate wattage output and impedance measurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Stryker","offers":[{"title":"Default Title","offer_id":48362259677409,"sku":"STRY0406900000","price":3825.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/copy-of-ebay_a0979bdf-21bc-47c7-8b49-1d90961af2dd.png?v=1778601297","url":"https:\/\/primismedical.com\/products\/stryker-multigen-medical-equipment-console-w-cables-powers-on","provider":"Primis Medical","version":"1.0","type":"link"}