{"product_id":"synthes206-016","title":"Synthes 206.016 4.0mm Cancellous Bone Screw Fully Threaded\/16mm","description":"\u003ch4 data-path-to-node=\"2\"\u003eSynthes 4.0mm Cancellous Bone Screw | Fully Threaded | 16mm Length | 206.016\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eSynthes 206.016\u003c\/b\u003e is a precision-engineered internal fixation implant designed specifically for engagement in cancellous (spongy) bone. As a \u003cb data-path-to-node=\"3\" data-index-in-node=\"143\"\u003e4.0mm diameter\u003c\/b\u003e screw with a \u003cb data-path-to-node=\"3\" data-index-in-node=\"171\"\u003e16mm length\u003c\/b\u003e, it is a foundational component of the \u003cb data-path-to-node=\"3\" data-index-in-node=\"222\"\u003eSynthes Small Fragment System\u003c\/b\u003e. This screw features a \u003cb data-path-to-node=\"3\" data-index-in-node=\"275\"\u003efully threaded\u003c\/b\u003e profile, providing maximum thread-to-bone contact across its entire length to ensure stable anchorage in low-density bone environments.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eForged from implant-grade \u003cb data-path-to-node=\"4\" data-index-in-node=\"26\"\u003e316L Stainless Steel\u003c\/b\u003e, the 206.016 is designed to provide high pull-out resistance in the porous matrix of the metaphysis or epiphysis, where cortical screws may lack sufficient \"grip.\"\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Synthes (DePuy Synthes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 206.016\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e 316L Stainless Steel (Surgical Grade)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eScrew Diameter:\u003c\/b\u003e 4.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eThread Profile:\u003c\/b\u003e Fully Threaded\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eScrew Length:\u003c\/b\u003e 16 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eThread Pitch:\u003c\/b\u003e 1.75 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eCore Diameter:\u003c\/b\u003e 1.9 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,8,0\"\u003e\u003cb data-path-to-node=\"6,8,0\" data-index-in-node=\"0\"\u003eHead Type:\u003c\/b\u003e 6.0 mm Head with Small Hexagonal Socket\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,9,0\"\u003e\u003cb data-path-to-node=\"6,9,0\" data-index-in-node=\"0\"\u003eQuantity:\u003c\/b\u003e Individually Packaged (Non-Sterile)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eOptimized Cancellous Pitch:\u003c\/b\u003e The 1.75 mm thread pitch is significantly deeper and wider than cortical designs. This geometry allows the threads to \"grasp\" the trabecular bone structure, maximizing surface area contact to prevent hardware loosening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eFull-Length Anchorage:\u003c\/b\u003e Because the screw is fully threaded, it distributes mechanical loads evenly across the entire 16mm interface. This is particularly advantageous in osteoporotic bone or for fixing small avulsion fragments where every millimeter of purchase is critical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eHigh-Torque Hex Drive:\u003c\/b\u003e The hexagonal recess is designed to transmit precise insertion torque, allowing the surgeon to feel the \"seat\" of the screw without the risk of stripping the head or damaging the bone matrix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eLow-Profile Spherical Head:\u003c\/b\u003e The 6.0 mm head sits flush within the counter-sunk holes of Synthes small fragment plates (e.g., 3.5mm LCP, DCP, or LC-DCP) or can be used with a \u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"174\"\u003e7.0mm washer\u003c\/b\u003e when fixed directly to the bone to prevent subsidence.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eBiomechanical Integrity:\u003c\/b\u003e Cold-worked for high fatigue strength, this 316L stainless steel implant is biologically inert and designed to withstand the cyclic loads of functional rehabilitation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eTrauma Surgery:\u003c\/b\u003e Stabilization of metaphyseal fractures in the distal radius, medial malleolus, or olecranon.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eAvulsion Fractures:\u003c\/b\u003e Securely anchoring small bone-tendon fragments (e.g., radial styloid or ankle ligaments).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003ePlate Fixation:\u003c\/b\u003e Serving as a \"buttress\" or \"neutralization\" screw through 3.5mm small fragment plating systems in regions of predominantly cancellous bone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003ePediatric Orthopedics:\u003c\/b\u003e Fixation of epiphyseal injuries where a short, 16mm reach is required to avoid growth plate interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eNEW — Original Manufacturer's Packaging.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eIntegrity:\u003c\/b\u003e This implant is new. As a \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"37\"\u003enon-sterile\u003c\/b\u003e component, it must be inspected for thread integrity and processed through a validated sterilization cycle (typically steam autoclaving) in accordance with hospital protocols and Synthes IFU (Instructions for Use) prior to clinical use in 2026.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eProfessional Standards:\u003c\/b\u003e With over \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"34\"\u003e25 years of experience\u003c\/b\u003e in surgical hardware, \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"79\"\u003ePrimis Medical\u003c\/b\u003e ensures all small fragment implants are maintained in optimal conditions to preserve the mechanical and sterile integrity of the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in protective packaging to ensure the precision-machined 4.0 mm threads and hexagonal socket remain pristine.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Screenshot_2025-09-16_081124_175803191368c970294abc82555.png?v=1758031914\" alt=\"Synthes\" width=\"350\" height=\"155\"\u003e\u003c\/p\u003e","brand":"Synthes","offers":[{"title":"Default Title","offer_id":45847622484193,"sku":"SYNT-206.016","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Shopify_-_2025-11-21T162608.181.jpg?v=1763767624","url":"https:\/\/primismedical.com\/products\/synthes206-016","provider":"Primis Medical","version":"1.0","type":"link"}