{"product_id":"v-mueller-gl2360-kahn-uterine-trigger-cannula-w-smith-nephew-tray","title":"V. Mueller GL2360 Kahn Uterine Trigger Cannula w\/ Smith \u0026 Nephew Tray","description":"\u003ch4 data-path-to-node=\"2\"\u003eV. Mueller Kahn Uterine Trigger Cannula Set | GL2360 | S\u0026amp;N Sterilization Tray\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eV. Mueller GL2360 Kahn Uterine Trigger Cannula\u003c\/b\u003e is a precision instrument engineered for the 2026 requirements of diagnostic gynecology. It is specifically designed for the administration of radiographic dyes  during hysterosalpingography (HSG) and tubal patency tests.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eFeaturing a unique \"trigger-squeeze\" mechanism, the GL2360 allows the clinician to seal the cervix without the need for traditional dilation or sounding. By pulling the cannula into the cervix while a tenaculum secures the cervical lip over the obturator, this system provides a leak-proof seal that is essential for accurate intrauterine pressure and clear diagnostic imaging.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Performance Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eTrigger-Squeeze Sealing:\u003c\/b\u003e Facilitates a secure, one-handed cervical seal. This technique minimizes patient discomfort by eliminating the mechanical dilation typically required for standard cannulas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eTapered Obturator Design:\u003c\/b\u003e Optimized for easy insertion into the external os, providing a snug fit that prevents dye backflow during high-pressure insufflation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eMulti-Component Accessory Kit:\u003c\/b\u003e This lot includes specialized attachment hardware, including a knurled accessory handle for enhanced grip and curved arm components for tailored positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eProtective Rubber Acorn Guards:\u003c\/b\u003e Includes both large and small black rubber \"acorns\" which serve as the primary cervical seal, ensuring compatibility with varying patient anatomies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eSmith \u0026amp; Nephew 7208209 Tray:\u003c\/b\u003e A high-durability, multi-purpose sterilization tray with a secure lid and perforated base. It is engineered to protect the rigid shaft of the cannula from bending or torque during the high-pressure environment of a steam autoclave.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eManufacturer (Cannula):\u003c\/b\u003e V. Mueller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e GL2360\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eSystem Type:\u003c\/b\u003e Kahn Uterine Trigger Cannula\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eOverall Length:\u003c\/b\u003e 12-5\/8\" (32 cm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eTray Manufacturer:\u003c\/b\u003e Smith \u0026amp; Nephew (7208209)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Premium Surgical-grade Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eLatex-Free:\u003c\/b\u003e Yes (Rubber components are medical-grade synthetic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eIncluded Inventory\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003e1x\u003c\/b\u003e V. Mueller GL2360 Cannula\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003e1x\u003c\/b\u003e S\u0026amp;N Sterilization Tray with Lid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003e1x\u003c\/b\u003e Accessory Handle (Knurled Grip)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003e1x\u003c\/b\u003e PTFE\/Plastic Tip Insert\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003e1x\u003c\/b\u003e Threaded Fastener \u0026amp; Spacer Collar\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-path-to-node=\"10,5,0\" data-index-in-node=\"0\"\u003e2x\u003c\/b\u003e Rubber Acorn Guards (Large \u0026amp; Small)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eClinical \u0026amp; Institutional Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eEnhanced Diagnostic Accuracy:\u003c\/b\u003e The airtight seal produced by the trigger mechanism ensures that dyes or gases are directed entirely into the uterine cavity and fallopian tubes, reducing \"false negative\" results caused by cervical leakage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eOrganized SPD Workflow:\u003c\/b\u003e The Smith \u0026amp; Nephew tray provides a dedicated footprint for the cannula and its small fasteners, drastically reducing the risk of lost parts during the decontamination and tray-assembly process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003ePatient Comfort:\u003c\/b\u003e The ability to perform patency checks without sounding or dilation significantly reduces procedural trauma and post-operative cramping for the patient.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eStrategic Procurement:\u003c\/b\u003e Acquiring this \"Really Good Condition\" set provides a high-end V. Mueller diagnostic tool and a professional S\u0026amp;N sterilization solution at a fraction of the cost of new-generation single-use manipulators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eIdeal Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eReproductive Endocrinology:\u003c\/b\u003e Hysterosalpingography (HSG) and tubal patency assessments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eGeneral Gynecology:\u003c\/b\u003e Uterine manipulation and dye instillation to check for perforations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eFertility Clinics:\u003c\/b\u003e Standard diagnostic workups for primary or secondary infertility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"15\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"8\"\u003eUsed — Really Good Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\"\u003eMechanical Integrity:\u003c\/b\u003e The trigger mechanism is smooth and responsive. The threaded fasteners and knurled handles show no signs of cross-threading or mechanical wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\"\u003eSurface Condition:\u003c\/b\u003e Surgical stainless steel is clean with no pitting or oxidation. The rubber acorn guards remain flexible and free of dry-rot or cracking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003e\u003cb data-path-to-node=\"16,3,0\" data-index-in-node=\"0\"\u003eSafety Note:\u003c\/b\u003e This instrument set is provided non-sterile. All components, including the tray and rubber guards, must undergo a validated ultrasonic cleaning and a steam autoclave cycle prior to clinical use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"V. Mueller","offers":[{"title":"Default Title","offer_id":48372049707233,"sku":"SMITUTERINE","price":169.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/primis-auctions-dotmed-5_254f3ee6-c8c8-4655-8fab-d40e17a940b7.png?v=1778867651","url":"https:\/\/primismedical.com\/products\/v-mueller-gl2360-kahn-uterine-trigger-cannula-w-smith-nephew-tray","provider":"Primis Medical","version":"1.0","type":"link"}