{"product_id":"zimmer-07-00442-001-st360-right-angle-anti-torque-handle","title":"Zimmer 07.00442.001 ST360° Right Angle Anti-Torque Handle","description":"\u003cdiv id=\"inkfrog_crosspromo_top\"\u003e\u003c\/div\u003e\n\u003c!-- Original design work, including graphics and all related scripts, Copyright (c) OCDesignsOnline.com, All Rights Reserved. Used with permission by Primis Medical. --\u003e\n\u003cdiv class=\"container\"\u003e\n\u003c!-- header--\u003e\n\u003cdiv id=\"header\"\u003e\n\u003cdiv id=\"x-head-top\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eZimmer ST360° Anti-Torque Handle | Right Angle | 07.00442.001 | Reusable\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eZimmer 07.00442.001\u003c\/b\u003e is a specialized high-torque manual instrument designed to provide counter-leverage during the insertion of orthopedic implants. Featuring a unique \u003cb data-path-to-node=\"3\" data-index-in-node=\"172\"\u003eRight Angle (90°)\u003c\/b\u003e configuration, this handle is a critical component of the \u003cb data-path-to-node=\"3\" data-index-in-node=\"248\"\u003eST360° system\u003c\/b\u003e, engineered to neutralize the rotational forces (torque) generated when tightening locking bolts, pedicle screws, or large-fragment fixations.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eBy allowing the surgeon to apply an equal and opposite \"anti-torque\" force perpendicular to the drive axis, the 07.00442.001 prevents the unintended rotation of the primary implant or the \"plowing\" of screws within the bone. This is particularly vital in spinal deformity correction and complex pelvic reconstructions where precise fixed-angle alignment must be maintained.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Zimmer (Zimmer Biomet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eSeries:\u003c\/b\u003e ST360° Orthopedic System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 07.00442.001\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eConfiguration:\u003c\/b\u003e Right Angle (90°) Anti-Torque\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eInterface:\u003c\/b\u003e Quick-Connect \/ Modular Bit Compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Medical-Grade Surgical Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eOperation:\u003c\/b\u003e Manual Ergonomic Leverage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eCleaning:\u003c\/b\u003e Fully Autoclavable \/ Reusable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eRight-Angle Mechanical Advantage:\u003c\/b\u003e The 90° offset design provides superior leverage compared to straight handles, allowing the surgical assistant or surgeon to stabilize the construct with significantly less physical effort.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eCompact Low-Profile Head:\u003c\/b\u003e Engineered to fit into tight anatomical corridors where a standard T-handle or straight anti-torque wrench would be obstructed by soft tissue or retractors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eAnti-Torque Stability:\u003c\/b\u003e This handle is essential for \"final tightening\" phases. It isolates the torque to the screw head, protecting the bone-to-implant interface from transverse stress and ensuring the locking mechanism reaches its full rated Newton-meter (Nm) capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eErgonomic Force Distribution:\u003c\/b\u003e The handle geometry is contoured to reduce wrist strain, providing a secure, non-slip grip even when used with double-gloving in high-fluid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eZimmer Industrial Forging:\u003c\/b\u003e Forged from high-tensile stainless steel, the 07.00442.001 is built to withstand extreme rotational loads without flexing, maintaining its structural integrity through years of heavy trauma and reconstructive use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eSpine Surgery:\u003c\/b\u003e Stabilizing pedicle screw-to-rod constructs during final nut tightening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eOrthopedic Trauma:\u003c\/b\u003e Providing counter-leverage when seating large 6.5mm or 7.3mm cannulated screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eIntramedullary Nailing:\u003c\/b\u003e Anti-torque support during the insertion of proximal or distal locking bolts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003ePelvic Reconstruction:\u003c\/b\u003e Managing high-torque fixations in deep, restricted-access surgical sites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eUsed – Good Usable Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eMaintenance:\u003c\/b\u003e This instrument shows visible signs of professional use (minor surface scuffs and cosmetic wear consistent with standard tray storage and repeated sterilization), but it remains \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"191\"\u003efully functional\u003c\/b\u003e. The internal drive interface is crisp, the right-angle head is securely seated, and the stainless steel frame is perfectly aligned.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eProfessional Standards:\u003c\/b\u003e With over \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"34\"\u003e25 years of experience\u003c\/b\u003e in surgical instrumentation and hospital materials, \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"109\"\u003ePrimis Medical\u003c\/b\u003e ensures all Zimmer orthopedic tools are function-verified and ultrasonically cleaned prior to shipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in protective, padded packaging to ensure the right-angle linkage and quick-connect interface arrive in factory-standard condition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Shopify_-_2026-01-27T135621.546.webp?v=1774970721\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Zimmer","offers":[{"title":"Default Title","offer_id":47901089071329,"sku":"ZIMM-07.00442.001","price":83.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Shopify_-_2026-01-27T135621.546.jpg?v=1769547632","url":"https:\/\/primismedical.com\/products\/zimmer-07-00442-001-st360-right-angle-anti-torque-handle","provider":"Primis Medical","version":"1.0","type":"link"}