{"product_id":"zimmer-07-00448-001-compressor-surgical-instrument","title":"Zimmer 07.00448.001 Compressor Orthopedic Instrument","description":"\u003cdiv id=\"inkfrog_crosspromo_top\"\u003e\u003c\/div\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eZimmer Orthopedic Compressor | 07.00448.001 | Reusable | Trauma \u0026amp; Spine\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eZimmer 07.00448.001\u003c\/b\u003e is a high-performance manual instrument engineered for the controlled approximation of bone fragments or orthopedic implants. As a core component of Zimmer Biomet’s advanced fixation suites, this compressor provides the mechanical leverage required to apply axial compression across a fracture site or between modular implant components (such as pedicle screws and rods).\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eBy facilitating precise bone-to-bone or bone-to-implant apposition, the 07.00448.001 ensures optimal biomechanical stability, which is a fundamental requirement for primary bone healing and the long-term success of internal fixation constructs.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Zimmer Biomet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 07.00448.001\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eProduct Type:\u003c\/b\u003e Orthopedic\/Spinal Compressor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e High-Tensile Surgical Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eMechanism:\u003c\/b\u003e Manual High-Torque Compression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eSystem Compatibility:\u003c\/b\u003e Optimized for Zimmer Trauma, Spinal, and Reconstructive sets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eCleaning:\u003c\/b\u003e Fully Autoclavable \/ Reusable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eControlled Axial Compression:\u003c\/b\u003e The 07.00448.001 allows for incremental, measured compression. This \"fine-tune\" capability is essential in spinal deformity correction and complex fracture fixations, where over-compression can lead to hardware failure or bone \"plowing.\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eHigh-Leverage Ergonomics:\u003c\/b\u003e The handle geometry is designed to multiply manual force, allowing the surgeon to achieve significant compressive loads with minimal physical strain. This ensures steady, jitter-free movement during critical reduction steps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003ePrecision-Machined Interface:\u003c\/b\u003e The contact points of the compressor are engineered to securely grip rods or screw heads without slipping. This \"zero-drift\" interface protects the surface integrity of titanium or cobalt-chrome implants, reducing the risk of notch-related fatigue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eSuperior Visibility:\u003c\/b\u003e The slim-profile design of the compressor arms ensures that the surgical field and the compression interface remain visible to the surgeon and under C-arm fluoroscopy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eIndustrial-Grade Durability:\u003c\/b\u003e Forged from medical-grade stainless steel, this instrument is built to withstand the high-torque environments of orthopedic surgery and the aggressive thermal cycles of repeated steam sterilization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eSpine Surgery:\u003c\/b\u003e Closing the gap between pedicle screws to induce lordosis or stabilize interbody spacers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eOrthopedic Trauma:\u003c\/b\u003e Applying axial compression across transverse or short-oblique fractures before final plate fixation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eReconstructive Surgery:\u003c\/b\u003e Stabilizing bone grafts and modular orthopedic components where high-strength apposition is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eGeneral Orthopedics:\u003c\/b\u003e Acting as a \"mechanical assistant\" to maintain reduction during the drilling and tapping phases of fixation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eUsed – Good Usable Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eMaintenance:\u003c\/b\u003e This instrument shows visible signs of professional use (minor surface scuffs or cosmetic \"tray wear\" consistent with standard hospital processing), but it remains \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"177\"\u003efully functional\u003c\/b\u003e. The compression mechanism is fluid, the pivot points are secure with no lateral \"play,\" and the stainless steel is free of pitting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eProfessional Standards:\u003c\/b\u003e With over \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"34\"\u003e25 years of experience\u003c\/b\u003e in surgical instrumentation and hospital materials, \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"109\"\u003ePrimis Medical\u003c\/b\u003e ensures all Zimmer orthopedic tools are function-verified and ultrasonically cleaned prior to shipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in protective, padded packaging to ensure the precision-machined compression arms and mechanical linkage remain in factory-standard alignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/305081709293-0_469db97b-b24c-4835-8d64-b26cbf3fcc71.jpg?v=1774974608\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Zimmer","offers":[{"title":"Default Title","offer_id":47849802367201,"sku":"ZIMM-07.00448.001","price":132.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/305081709293-0.jpg?v=1768338351","url":"https:\/\/primismedical.com\/products\/zimmer-07-00448-001-compressor-surgical-instrument","provider":"Primis Medical","version":"1.0","type":"link"}