{"product_id":"zimmer-2360-166-25-standard-hex-surgical-driver-2-5mm","title":"Zimmer 2360-166-25 Standard Hex Surgical Driver 2.5mm","description":"\u003cdiv id=\"inkfrog_crosspromo_top\"\u003e\u003c\/div\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eZimmer Standard Hex Driver | 2.5mm Hex | Cannulated | 2360-166-25 | Reusable\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eZimmer 2360-166-25\u003c\/b\u003e is a high-precision manual surgical driver engineered for the insertion and final seating of \u003cb data-path-to-node=\"3\" data-index-in-node=\"116\"\u003e2.5mm hex-head screws\u003c\/b\u003e. As a core component of Zimmer Biomet’s \u003cb data-path-to-node=\"3\" data-index-in-node=\"178\"\u003esmall-fragment and periarticular locking systems\u003c\/b\u003e, this driver is essential for the internal fixation of fractures in the distal radius, fibula, and humerus.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eA key technical feature of this model is its \u003cb data-path-to-node=\"4\" data-index-in-node=\"45\"\u003ecannulated shaft\u003c\/b\u003e, which allows the driver to be passed over a guide wire (typically 1.1mm or 1.25mm). This ensures perfect axial alignment during screw insertion, preventing \"walking\" or stripping of the screw head in complex anatomical sites where visibility may be restricted.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Zimmer Biomet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eModel \/ REF:\u003c\/b\u003e 2360-166-25\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eProduct Type:\u003c\/b\u003e Standard Hex Driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eHex Size:\u003c\/b\u003e 2.5mm (Precision Ground)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eConfiguration:\u003c\/b\u003e Cannulated (Wire-Guided Compatibility)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eInterface:\u003c\/b\u003e Quick-Connect (AO\/Synthes Style Compatible)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e High-Tensile Surgical Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eCleaning:\u003c\/b\u003e Fully Autoclavable \/ Reusable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical \u0026amp; Clinical Advantages\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e2.5mm Precision Hex Interface:\u003c\/b\u003e The hex tip is precision-machined to ensure a high-torque mechanical interlock with the screw head. This minimizes the risk of \"rounding out\" the hex recess during high-torque applications in dense cortical bone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eCannulated Alignment Control:\u003c\/b\u003e The internal lumen allows for a \"Seldinger-style\" approach over a K-wire. This is particularly advantageous in percutaneous or minimally invasive (MIS) procedures, where maintaining the trajectory of the pilot hole is critical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eExtended Reach Shaft:\u003c\/b\u003e The elongated driver body is designed to clear soft tissue protectors and drill guides, providing the surgeon with an unobstructed view of the screw-to-plate interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eStandard AO Quick-Connect:\u003c\/b\u003e Featuring a universal quick-connect shank, this driver integrates seamlessly with modular T-handles, ratcheting handles, and powered surgical drivers found in standard small-fragment trays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eZimmer Industrial Durability:\u003c\/b\u003e Forged from medical-grade stainless steel, the 2360-166-25 is built to maintain its hex tolerances through years of high-torque manual use and repeated sterilization cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eApplications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eOrthopedic Trauma:\u003c\/b\u003e Internal fixation of distal radius, fibula, and distal humerus fractures using 3.5mm or 4.0mm screws with 2.5mm hex heads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003ePeriarticular Plating:\u003c\/b\u003e Final tightening of locking screws in periarticular and Universal Locking Systems (ULS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eSmall Fragment Reconstruction:\u003c\/b\u003e Any procedure requiring the placement of 2.5mm hex-driven hardware over a guide wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCondition \u0026amp; Quality Assurance\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eStatus:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"8\"\u003eUsed – Good Usable Condition.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eMaintenance:\u003c\/b\u003e This instrument shows visible signs of professional use (minor surface scuffs consistent with standard tray storage and autoclaving), but it remains \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"162\"\u003efully functional\u003c\/b\u003e. The 2.5mm hex tip is crisp and free of rounding, the cannulation is clear and unobstructed, and the quick-connect interface is secure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eProfessional Standards:\u003c\/b\u003e With over \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"34\"\u003e25 years of experience\u003c\/b\u003e in surgical instrumentation and hospital materials, \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"109\"\u003ePrimis Medical\u003c\/b\u003e ensures all Zimmer orthopedic tools are function-verified and ultrasonically cleaned prior to shipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eShipping \u0026amp; Handling\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSecure Logistics:\u003c\/b\u003e Shipped in protective, padded packaging to ensure the precision 2.5mm hex tip and cannulated shaft remain in factory-standard condition during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eFast Dispatch:\u003c\/b\u003e Ships within 1 business day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Shopify_-_2026-01-20T124350.800_dd5af82f-575f-4587-9ac9-975c9c776aeb.jpg?v=1774972858\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Zimmer","offers":[{"title":"Default Title","offer_id":47871796936929,"sku":"ZIMM-2360-166-25","price":48.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/0527\/8543\/files\/Shopify_-_2026-01-20T124350.800.jpg?v=1768938352","url":"https:\/\/primismedical.com\/products\/zimmer-2360-166-25-standard-hex-surgical-driver-2-5mm","provider":"Primis Medical","version":"1.0","type":"link"}