AMSINO IV Admin Set, 10 Drops/mL, 96" Length, 19 mL Priming, Non-Vented, Roller Clamp, 2 Y Sites, Rotating Male Luer Lock, PE Pouch, 50/cs
AMSINO IV Admin Set, 10 Drops/mL, 96" Length, 19 mL Priming, Non-Vented, Roller Clamp, 2 Y Sites, Rotating Male Luer Lock, PE Pouch, 50/cs is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
AMSINO IV Admin Set, 10 Drops/mL, 96" Length, 19 mL Priming, Non-Vented, Roller Clamp, 2 Y Sites, Rotating Male Luer Lock, PE Pouch, 50/cs
• Drip factor: 10 drops per mL
• Tubing length: 96 inches (≈ 244 cm)
• Priming volume: 19 mL (approximate)
• Venting: Non‑vented spike (i.e. no air vent)
• Clamp / Flow control: Roller clamp
• Y Sites: 2 injection Y‑sites (standard / pre‑pierced)
• Connectors: Rotating male Luer Lock distal connection
The AMSINO 96‑inch, 10 drops/mL IV administration set (109602) is designed for standard gravity infusion of fluids or medications. With a drip rate of 10 drops per milliliter, it offers relatively moderate resolution in infusion rate control—neither extremely fine nor coarse—making it suitable for many general inpatient and outpatient IV uses. The extended tubing length (96") provides flexibility in positioning the fluid source and accommodating patient movement without stressing the line.
This set is configured with two injection Y‑sites, which allow clinicians to introduce medications or additional fluids into the main infusion line without disconnecting it. Having dual Y‑ports can be especially useful when multiple medications must be administered over the same access. The roller clamp allows smooth, adjustable control of flow rate throughout the infusion. The rotating male luer lock connector ensures a secure connection to downstream catheters or extension tubing, while letting the tubing twist slightly without applying torque to the connection.
From a materials and safety standpoint, this IV set is manufactured to modern medical device standards. It is DEHP-free, latex-free, sterile, and non‑pyrogenic, which helps minimize the risks of allergic reactions or toxic leachables when used with patients, particularly in sensitive populations. The non‑vented spike helps maintain a closed system, reducing risk of air ingress. The priming volume (~19 mL) is comparatively moderate for a set of this length, so care must be taken during setup to fully purge air before connecting to the patient. Clinically, this set is well suited for routine IV infusions in wards, infusion suites, or general clinical settings where dual-line medication access is needed.