Arthrex Autoclavable Arthroscopy Pump Remote Control AR-6495, For DualWave & Continuous Wave 4 Systems

$100.00
Taxes, discounts and shipping calculated at checkout.

Arthrex Autoclavable Pump Remote Control | AR-6495

The Arthrex AR-6495 is a heavy-duty, reusable fluid management accessory engineered to give the sterile surgical team absolute command over their arthroscopic environment. Operating as a direct interface with industry-standard Arthrex fluid towers, this remote brings mission-critical pump dynamics directly into the sterile field, bypassing the need for verbal instruction to unsterile circulating staff.

By placing immediate flow and pressure adjustments at the fingertips of the surgeon or scrub technician, the AR-6495 ensures rapid response times to intra-articular bleeding or visual clouding, maintaining chamber clarity throughout complex joint reconstructions.

Key Performance Features

  • Sterile-Field Fluid Autonomy: Completely eliminates communication latency between the surgeon and the fluid tower, optimizing operating room efficiency and pacing during time-sensitive arthroscopic procedures.

  • DualWave™ & Continuous Wave™ Synergy: Custom-calibrated to interface seamlessly with both the Arthrex DualWave™ (AR-6480) and Continuous Wave™ 4 (AR-6485) arthroscopy pump platforms.

  • Hermetically Sealed Tactile Interface: The internal electronic switches are permanently sealed against moisture. This prevents fluid ingress from aggressive hand-washing or intraoperative splashes, mitigating button failure.

  • Dual-Sterilization Versatility: Fully autoclavable and built to withstand repeated high-temperature steam cycles. For facilities prioritizing rapid turnover, it can also be enclosed in a standard AR-6307 sterile remote drape.

  • Reinforced Strain-Relief Cable: The heavy-duty cord features an industrial-grade outer jacket designed to resist kinks, coil separation, and internal wire fracturing caused by tight bundling or frequent manipulation.

Key Controls Available at Your Fingertips

  • Pressure Optimization: Increase or decrease intra-articular pressure instantly to adapt to changing vascular or visualization demands within the joint capsule.

  • LAVAGE Mode Activation: Triggers a timed pressure boost to clear acute bleeding via localized tamponade, instantly re-establishing a clear view without disrupting the workflow.

  • RINSE Flow Control: Boosts the fluid flow rate to vigorously flush out troublesome bone fragments, soft tissue debris, and synovial fluid clouding.

  • RUN/STOP Override: Allows the sterile team to pause fluid flow instantly during scope exchanges or instrument transitions, conserving fluid and preventing accidental operating room spray.

Technical Specifications

  • Manufacturer: Arthrex

  • Product Code: AR-6495

  • Device Type: Fluid Management Remote Control

  • Housing Material: High-grade, impact-resistant medical polymers

  • Format: Reusable / Fully Autoclavable

  • Compatibility: Arthrex DualWave (AR-6480) & Continuous Wave 4 (AR-6485)

Clinical & Institutional Advantages

  • Interrupted Workflow Mitigation: Provides a highly reliable alternative to foot pedals, which frequently slide out of the surgeon's reach or become trapped beneath fluid collection mats.

  • Per-Case Fluid Conservation: The rapid RUN/STOP response helps prevent fluid waste during transitions, extending the lifespan of the fluid bags and reducing the frequency of intraoperative bag changes.

  • Durable Capital Asset Preservation: Forged from robust, impact-resistant polymers that absorb the shock of accidental operating room drops onto hard tile surfaces.

  • Strategic Procurement: Sourcing this essential workflow accessory in [Insert Condition] allows ambulatory surgery centers (ASCs) to provide a premium, seamless interface for their sports medicine specialists while preserving operational capital.

Ideal Applications

  • Sports Medicine: High-volume knee, shoulder, and hip arthroscopy.

  • Ambulatory Surgery Centers: Streamlining joint debridements and repair sets.

  • Academic Teaching Hospitals: Allowing attending surgeons to safely monitor and adjust fluid parameters while guiding fellows through joint visualization.

Quality Assurance & Condition

  • Status: Used

  • Biomedical Validation: Buttons and communication relays have been thoroughly bench-tested to ensure tactile responsiveness and 1:1 data translation to the host pump console.

  • Note to SPD: When utilizing the autoclave protocol, ensure the cable is loosely coiled (minimum 6-inch diameter) to prevent long-term stress on the inner copper shielding. Do not allow other heavy metal orthopedic instruments to be stacked on top of the remote face.

No reviews available.

The Primis TeamProudly Supports

  • DAMIEN HOUSE

    Located in Guayaquil, Ecuador, Damien House exists to provide care and help dispel the stigma of those affected by Hansen's Disease (Leprosy).

  • PROJECT PERFECT WORLD

    Project Perfect World provides orthopedic surgery for children worldwide.