Masimo 4053 RED SET TCI Adult Reusable Ear Sensor 3' (0.9 m) SpO₂ Probe
Masimo 4053 RED SET TCI Adult Reusable Ear Sensor 3' (0.9 m) SpO₂ Probe is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Masimo 4053 RED SET TCI Adult Reusable Ear Sensor 3' (0.9 m) SpO₂ Probe
The Masimo 4053 is a specialized, reusable pulse oximetry sensor designed for adult patients who require consistent SPO2 monitoring when peripheral sites (fingers/toes) are unavailable or unreliable. As part of the RED SET® TCI series, this sensor is engineered to provide superior signal capture in challenging clinical conditions, including patients with low perfusion or those undergoing cardiovascular procedures.
Technical specifications
- Brand: Masimo
- Reference / model: 4053
- Model: Number: 4053 (RED SET TCI-3)
Additional product details
- The ear-clip design offers an alternative monitoring site that is less susceptible to the vasoconstriction often seen in the extremities.
- Manufacturer: Masimo
- Sensor Type: Reusable Ear Sensor (Adult)
- Cable Length: 3 feet (0.9 meters)
- Technology: RED SET® TCI (Trauma, Critical care, and Isolation)
- Compatibility: Designed for use with Masimo RED SET patient cables and monitors.
- Reduced Motion Artifact: Because the head is typically more stable than the hands, the ear sensor is less prone to "false alarms" caused by patient movement.
- Cost-Effective: As a reusable probe, the 4053 reduces the "per-patient" cost associated with disposable sensors in long-term monitoring environments.
- New & Unused: This probe is in its original, unopened manufacturer’s packaging.
- Storage: Cleanly stored in a climate-controlled facility to preserve the silicone and electrical components.
- This Masimo sensor is guaranteed to arrive in new, functional condition. If the probe fails to provide a reading or is incompatible with your RED SET system upon arrival, Primis Medical will provide a full refund or replacement.
- The Masimo 4053 is a vital tool for:
- ICU & Critical Care: Monitoring hemodynamically unstable patients.
- Operating Rooms: Ideal for cases where the hands are tucked or inaccessible.
- Emergency Medicine: Fast SPO2 assessment in trauma or cold-exposure cases.
- Sleep Labs: A stable alternative for overnight oxygen saturation studies.
- (1) Masimo 4053 RED SET TCI Adult Reusable Ear Sensor (3ft)