Synthes 201.622 2.4mm Cortex Screw Self-Tapping/22mm
Synthes 201.622 2.4mm Cortex Screw Self-Tapping/22mm is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Synthes 201.622 2.4mm Cortex Screw Self-Tapping/22mm
As a 2.4mm diameter screw with a 22mm length, it is a foundational component of the Synthes 2.4mm Small Fragment System.
Technical specifications
- Brand: Synthes
- Reference / model: 201.622
- Model: / REF: 201.622
- Material: 316L Surgical Stainless Steel
- Diameter: 2.4 mm
- Overall Length: 22 mm
Additional product details
- The self-tapping design features precision-machined cutting flutes at the distal tip. While a pilot hole must still be drilled (typically using a 1.8mm drill bit), the screw eliminates the need for a separate tapping step by cutting its own internal threads as it advances.
- Manufacturer: Synthes (DePuy Synthes)
- Thread Pitch: 1.0 mm (Standard Cortex Pitch)
- Drive Type: Cruciform Recess / StarDrive (Verify per set configuration)
- Features: Self-Tapping Distal Flutes
- Quantity: 1 Each
- The 22mm length provides sufficient depth for bicortical purchase in the metacarpals, metatarsals, or distal radius.
- Low-Profile Head Design: The screw head is designed to sit flush within Synthes 2.4mm plating systems (such as LCP or distal radius plates).
- 316L Stainless Steel Biocompatibility: Forged from vacuum-melted surgical steel, the 201.622 offers the high fatigue strength and corrosion resistance required for long-term internal fixation throughout the 2026 recovery cycle.
- Hand & Wrist Surgery: Fixation of metacarpal and phalangeal fractures, and distal radius plate stabilization.
- Foot & Ankle Surgery: Fixation of small bone fragments in the midfoot or phalanges of the toes.
- Small Fragment Trauma: Supplemental fixation for avulsion fractures where a larger 3.5mm screw would be too intrusive.
- Pediatric Trauma: Stable fixation of small fragments where a 2.4mm diameter provides the necessary strength without damaging smaller bone structures.
- Status: NEW — Factory Sealed.
- Integrity: This implant is securely housed within its original manufacturer's packaging. Both inner and outer seals are intact, ensuring full material integrity and suitability for clinical use.
- Sterilization Note: This device is provided as a NON-STERILE implant. It MUST be properly cleaned and sterilized via validated steam autoclave protocols in accordance with hospital guidelines and Synthes’ Instructions for Use (IFU) prior to clinical implantation.
Condition
New.
No reviews available.
The Primis TeamProudly Supports
-
DAMIEN HOUSE
Located in Guayaquil, Ecuador, Damien House exists to provide care and help dispel the stigma of those affected by Hansen's Disease (Leprosy).
-
PROJECT PERFECT WORLD
Project Perfect World provides orthopedic surgery for children worldwide.