Synthes 208.410 6.5mm Cannulated Screw 16mm Thread 75mm
The Synthes 208.410 is a robust internal fixation implant designed for high-load applications in large bone structures. As a 6.5mm diameter cannulated screw, it features a hollow central core that allows for precise placement over a pre-positioned 2.8mm guide wire.
Technical specifications
- Brand: Synthes
- Reference / model: 208.410
- Model: / REF: 208.410
- Material: 316L Stainless Steel (Surgical Grade)
- Dimensions / sizes: 6.5mm, 16mm, 75mm
Additional product details
- The 16mm Short Thread configuration is specifically engineered to create a powerful lag effect.
- Manufacturer: Synthes (DePuy Synthes)
- Screw Diameter: 6.5 mm
- Thread Profile: 16mm Short Thread (Partial)
- Screw Length: 75 mm
- Cannulation: Compatible with 2.8mm Guide Wires
- Head Type: 4.0mm Hexagonal Socket
- Quantity: Individually Packaged, Sterile
- Guide-Wire Precision: The cannulated design is essential for minimally invasive (percutaneous) techniques.
- Because the threads do not cross the fracture line in the proximal bone, the screw acts as a mechanical vice, pulling the distal bone toward the head.
- High-Torque Hex Drive: The 4.0mm hexagonal recess provides the structural integrity required to transmit the high torque levels necessary for deep insertion into the femoral or pelvic cortex without stripping.
- 316L Stainless Steel Biocompatibility: Forged for high fatigue resistance, this material is designed to withstand the significant cyclic loads associated with hip and pelvic fractures during the healing process.
- Hip Surgery: Fixation of femoral neck fractures (intracapsular) using a parallel "inverted triangle" screw configuration.
- Pelvic & Acetabular Trauma: Stabilization of sacroiliac (SI) joint disruptions and slipped capital femoral epiphysis (SCFE).
- Knee Surgery: Compression of large tibial plateau fractures or distal femoral condyle fractures.
- Arthrodesis: Large-joint fusions, including triple arthrodesis of the foot and ankle.
- Status: NEW — Factory Sealed & Sterile.
- Integrity: This implant is securely packaged within its original manufacturer's sterile peel-pouch. The packaging is intact, ensuring the product's sterility, material integrity, and full lot traceability for clinical use in 2026 and beyond.