Synthes 208.439 6.5MM Cannulated Screw 32MM Thread 85MM
Synthes 208.439 6.5MM Cannulated Screw 32MM Thread 85MM is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Synthes 208.439 6.5MM Cannulated Screw 32MM Thread 85MM
As a 6.5mm diameter cannulated screw, it features a hollow central core that allows for precise insertion over a pre-positioned 2.8mm guide wire. This system is the clinical standard for "percutaneous" or minimally invasive techniques, enabling the surgeon to achieve perfect anatomical alignment via fluoroscopy before the screw is advanced.
Technical specifications
- Brand: Synthes
- Reference / model: 208.439
- Model: / REF: 208.439
- Material: 316L Stainless Steel (Surgical Grade)
- Dimensions / sizes: 6.5MM, 32MM, 85MM
Additional product details
- The 32mm Long Thread configuration (partially threaded) is engineered to provide a powerful lag effect.
- Manufacturer: Synthes (DePuy Synthes)
- Screw Diameter: 6.5 mm
- Thread Profile: 32 mm Partial Thread (Long Thread)
- Screw Length: 85 mm
- Cannulation: Compatible with 2.8 mm Guide Wires
- Head Type: 4.0 mm Hexagonal Socket
- Quantity: Individually Packaged, Sterile
- Guide-Wire Precision: The cannulated design allows for "over-the-wire" insertion. Once the guide wire trajectory is verified, the screw follows the wire exactly, eliminating the risk of "wandering" in dense cancellous bone.
- It provides a massive "grip" in the distal bone, allowing the screw head to act as a mechanical vice to close the fracture gap.
- High-Torque Hex Drive: The 4.0mm hexagonal recess is designed to transmit the high levels of torque required to seat an 85mm screw into the femoral neck or pelvic cortex without stripping the head.
- 316L Stainless Steel Biocompatibility: Forged for high fatigue resistance, the material is designed to withstand the significant cyclic loads associated with weight-bearing in the femur and tibia during the healing process.
- Hip Surgery: Fixation of femoral neck fractures (intracapsular) and slipped capital femoral epiphysis (SCFE).
- Pelvic & Acetabular Trauma: Stabilization of sacroiliac (SI) joint disruptions and large pelvic ring fractures.
- Knee Trauma: Compression of large tibial plateau fractures or distal femoral condyle fractures where a long reach (85mm) is required.
- Arthrodesis: Large-joint fusions requiring significant compressive force across the joint space.
- Status: NEW — Factory Sealed & Sterile.
- Integrity: This implant is securely packaged within its original manufacturer's sterile peel-pouch. The packaging is intact, ensuring the product's sterility, material integrity, and full lot traceability for clinical implantation in 2026.
Condition
New.
No reviews available.
The Primis TeamProudly Supports
-
DAMIEN HOUSE
Located in Guayaquil, Ecuador, Damien House exists to provide care and help dispel the stigma of those affected by Hansen's Disease (Leprosy).
-
PROJECT PERFECT WORLD
Project Perfect World provides orthopedic surgery for children worldwide.

