Zimmer 2360-11-02 Reduction Sleeve 3.5/2.7mm Orthopedic Preowned
Zimmer 2360-11-02 Reduction Sleeve 3.5/2.7mm Orthopedic Preowned is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Zimmer 2360-11-02 Reduction Sleeve 3.5/2.7mm Orthopedic Preowned
Specifically designed for use within Zimmer Biomet’s Small Fragment and Periarticular Locking Systems, this reduction sleeve acts as a concentric spacer.
Technical specifications
- Brand: Zimmer
- Reference / model: 2360-11-02
- Model: / REF: 2360-11-02
- Material: Medical-Grade Surgical Stainless Steel
Additional product details
- By bridging the gap between 3.5mm and 2.7mm instrument footprints, the 2360-11-02 provides the "telescoping" accuracy required for lag-screw techniques and fixed-angle plating where even a sub-millimeter deviation in the pilot hole can compromise the mechanical integrity of the locking construct.
- Manufacturer: Zimmer Biomet
- Product Type: Reduction / Centering Sleeve
- Outer Diameter Compatibility: 3.5mm Systems
- Inner Diameter Compatibility: 2.7mm Instrumentation
- Configuration: Cannulated / Nested Guide
- Cleaning: Fully Autoclavable / Reusable
- Concentric Alignment Precision: The 2360-11-02 eliminates "drill wander" when transitioning between different screw sizes.
- This allows for rapid intraoperative adjustments without switching out entire drill guide assemblies.
- Low-Profile Surgical Access: The slim, knurled-top design allows for easy manual insertion and removal from drill guides, even when used deep within soft-tissue corridors or under fluoroscopic guidance.
- Orthopedic Trauma: Internal fixation of distal radius, fibula, and humerus fractures.
- Periarticular Plating: Centering 2.7mm screws within 3.5mm locking plate holes for multi-fragment stabilization.
- Lag Screw Technique: Preparing the "pilot hole" component of a 3.5mm/2.7mm lag screw construct.
- Small Fragment Reconstruction: Any procedure requiring nested instrumentation within Zimmer's Universal Locking System (ULS).
- Status: Used – Good Usable Condition.
- Maintenance: This instrument shows visible signs of professional use (minor surface scuffs or cosmetic wear consistent with standard tray storage and repeated autoclaving), but it remains fully functional. The internal lumen is clear and unobstructed, the 3.5/2.7mm tolerances are factory-spec, and the stainless steel is free of pitting.
Condition
Preowned.
No reviews available.
The Primis TeamProudly Supports
-
DAMIEN HOUSE
Located in Guayaquil, Ecuador, Damien House exists to provide care and help dispel the stigma of those affected by Hansen's Disease (Leprosy).
-
PROJECT PERFECT WORLD
Project Perfect World provides orthopedic surgery for children worldwide.


