Zimmer 2360-205-27 Periarticular Locking Plate System Drill Bit Standard 2.7mm 8-3/8" Preowned
Zimmer 2360-205-27 Periarticular Locking Plate System Drill Bit Standard 2.7mm 8-3/8" Preowned is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Zimmer 2360-205-27 Periarticular Locking Plate System Drill Bit Standard 2.7mm 8-3/8" Preowned
With a 2.7mm diameter, this bit is the clinical standard for creating pilot holes for 2.7mm locking or non-locking screws, as well as gliding holes for smaller fragment constructs.
Technical specifications
- Brand: Zimmer
- Reference / model: 2360-205-27
- Model: / REF: 2360-205-27
- Diameter: 2.7mm (Precision Ground)
- Overall Length: 8-3/8 Inches (21.3 cm)
- Material: High-Carbon Surgical Stainless Steel
Additional product details
- The defining characteristic of this model is its extended 8-3/8 inch (21.3 cm) overall length. This extra-long profile is specifically designed to clear bulky soft tissue, navigate deep surgical corridors, and pass through tall percutaneous drill guides used in Minimally Invasive Plate Osteosynthesis (MIPO). Whether addressing the proximal humerus, distal radius, or tibial plateau, this bit provides the reach necessary to maintain a perpendicular drilling trajectory without interference from the surrounding anatomy or surgical retractors.
- Manufacturer: Zimmer Biomet
- Series: Periarticular Locking Plate System
- Interface: Standard Quick-Connect (AO-Style)
- Operation: Powered or Manual (via compatible QC handpiece)
- Cleaning: Fully Autoclavable / Reusable
- This reduces friction-induced heat, protecting the surrounding bone from thermal necrosis—a critical factor for successful osseointegration in periarticular locking constructs.
- Industrial-Grade Forging: Built to withstand the torque required for penetrating dense cortical bone at the metaphysis, the 2360-205-27 maintains its axial straightness and cutting-edge sharpness through repeated clinical use.
- Upper Extremity Trauma: Pilot hole preparation for 2.7mm screws in proximal humerus and distal radius plates.
- Lower Extremity Trauma: Accessing the tibial plateau or distal fibula through deep soft-tissue envelopes.
- MIPO Techniques: Drilling through percutaneous tissue sleeves and remote targeting guides.
- Status: Used – Good Usable Condition.
- Maintenance: This instrument shows visible signs of professional use (minor surface scuffs or cosmetic "tray wear" consistent with standard hospital processing), but it remains fully functional. The 2.7mm cutting flutes are intact, the shaft has been verified for straightness, and the quick-connect interface is secure.
Condition
Preowned.
No reviews available.
The Primis TeamProudly Supports
-