AMSINO Pediatric Basic IV Set, 60 Drops/mL, 83" Length, 17 mL Priming, Non-Vented, Roller Clamp, 1 Pre-Pierced Y Site, 1 AMSafe Needle-Free Y Site, Rotating Male Luer Lock, PE Pouch, 50/cs

SKU: AMSI-608306
$155.25
Taxes, discounts and shipping calculated at checkout.

AMSINO Pediatric Basic IV Set, 60 Drops/mL, 83" Length, 17 mL Priming, Non-Vented, Roller Clamp, 1 Pre-Pierced Y Site, 1 AMSafe Needle-Free Y Site, Rotating Male Luer Lock, PE Pouch, 50/cs

  • • AMSINO
    Product / Catalog: AMSINO Pediatric Basic IV Set 608306 AMSINO Pediatric Basic IV Set 608306|
    Drip Factor: 60 drops per mL
    Tubing Length: 83 in (≈ 211 cm)
    Priming Volume: ~ 17 mL
    Spike / Venting: Non‑vented (closed system)
    Flow Control: Roller clamp
    Y‑Sites: 1 pre‑pierced Y site + 1 AMSafe needle‑free Y site
    Connector: Rotating male Luer lock

    The AMSINO Pediatric Basic IV Set 608306 is designed specifically for pediatric IV therapy, where precise control of small volumes and safe access are essential. With a drip factor of 60 drops/mL, this set allows for fine resolution in infusion rates, which is particularly important in smaller patients or when administering potent medications. The 83″ tubing provides enough length to route the infusion from the bag to bedside or pole positions without strain, while the ~17 mL priming volume keeps the added fluid load modest.

    This set’s dual Y‑site configuration offers versatility in clinical use: one pre‑pierced Y site permits standard syringe or additive access, while the AMSafe needle‑free Y site offers a closed, needleless port to enhance safety during medication administration or flushing. The roller clamp allows smooth control of infusion speed throughout administration. At its distal end, the rotating male Luer lock ensures a secure, leak-resistant connection to catheters or downstream devices while permitting rotation of the tubing to reduce twisting forces.

    From a materials and safety standpoint, the 608306 set is built with modern safety features. It is DEHP-free and latex-free, reducing the risk of exposure to problematic plasticizer leachables or latex allergies. The non-vented design helps maintain a closed system, minimizing risk of air entry. Its sterile, single-use nature, combined with pediatric-optimized flow control and dual-access ports, makes it a reliable choice for clinicians managing pediatric intravenous therapy.