GE Proteus 46-155400G46 / 46-155318G33 Imaging Tube DOM: 10-2018 Preowned
GE Proteus 46-155400G46 / 46-155318G33 Imaging Tube DOM: 10-2018 Preowned is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
GE Proteus 46-155400G46 / 46-155318G33 Imaging Tube DOM: 10-2018 Preowned
The GE 46-155400G46 (MX100 09PS) is a premium, rotating-anode X-ray tube assembly engineered for the demanding workflow of GE Proteus and Definium radiography systems. This unit features the MX-100 insert (Part #2336058), renowned for its excellent thermal capacity and consistent output during heavy-duty orthopedic and general radiographic procedures.
Technical specifications
- Brand: GE
- Model: Numbers: 46-155400G46 / 46-155318G33
- Model: MX100 09PS (Insert #2336058)
- Manufacture date: (DOM): October 2018
- Power: Rating: 40–100 kW
- Serial number: 104964TY2
Additional product details
- With a dual focal spot of 0.6 mm / 1.25 mm, this tube provides the versatility required for both high-detail extremity imaging and high-power abdominal or chest studies.
- Manufacturer: GE Healthcare
- Insert
- Focal Spots: 0.6 mm (Fine) / 1.25 mm (Large)
- Broad GE Compatibility: Beyond the Proteus XR/a, this tube is compatible with various GE imaging platforms, including the Definium 8000, Discovery, and Revolution XRD (verification by system serial number recommended).
- Status: Used – Harvested System Subcomponent.
- Extraction Note: This tube was professionally extracted from an overhead Proteus Rad-Room system by experienced technicians. It was handled with extreme care to protect the high-voltage receptacles and oil-filled housing.
- Functional Assessment: Being sold as a "Tested Functional" part. While the tube was performing within OEM specifications at the time of removal, the buyer is responsible for performing a professional "Seasoning" (warm-up) procedure and vacuum integrity check by a certified physicist or biomedical engineer prior to clinical use.
- ✔ Primis "Integrity-First" Guarantee We guarantee the tube will arrive free of oil leaks and physical housing damage. Due to the sensitive nature of X-ray vacuum inserts, Primis Medical recommends installation by a qualified GE-trained technician to ensure proper calibration and system handshake.
- (1) GE Proteus MX100 09PS Imaging Tube Assembly (46-155400G46)
Condition
Preowned.
No reviews available.
The Primis TeamProudly Supports
-
DAMIEN HOUSE
Located in Guayaquil, Ecuador, Damien House exists to provide care and help dispel the stigma of those affected by Hansen's Disease (Leprosy).
-
PROJECT PERFECT WORLD
Project Perfect World provides orthopedic surgery for children worldwide.