GE Proteus 46-155400G46 / 46-155318G33 Imaging Tube DOM: 10-2018 Preowned

SKU: GEPR-155400G46
$2,695.50
Taxes, discounts and shipping calculated at checkout.

GE Proteus 46-155400G46 / 46-155318G33 Imaging Tube DOM: 10-2018 Preowned

The GE 46-155400G46 (MX100 09PS) is a premium, rotating-anode X-ray tube assembly engineered for the demanding workflow of GE Proteus and Definium radiography systems. This unit features the MX-100 insert (Part #2336058), renowned for its excellent thermal capacity and consistent output during heavy-duty orthopedic and general radiographic procedures.

Technical specifications

  • Brand: GE
  • Model: Numbers: 46-155400G46 / 46-155318G33
  • Model: MX100 09PS (Insert #2336058)
  • Manufacture date: (DOM): October 2018
  • Power: Rating: 40–100 kW
  • Serial number: 104964TY2

Additional product details

  • With a dual focal spot of 0.6 mm / 1.25 mm, this tube provides the versatility required for both high-detail extremity imaging and high-power abdominal or chest studies.
  • Manufacturer: GE Healthcare
  • Insert
  • Focal Spots: 0.6 mm (Fine) / 1.25 mm (Large)
  • Broad GE Compatibility: Beyond the Proteus XR/a, this tube is compatible with various GE imaging platforms, including the Definium 8000, Discovery, and Revolution XRD (verification by system serial number recommended).
  • Status: Used – Harvested System Subcomponent.
  • Extraction Note: This tube was professionally extracted from an overhead Proteus Rad-Room system by experienced technicians. It was handled with extreme care to protect the high-voltage receptacles and oil-filled housing.
  • Functional Assessment: Being sold as a "Tested Functional" part. While the tube was performing within OEM specifications at the time of removal, the buyer is responsible for performing a professional "Seasoning" (warm-up) procedure and vacuum integrity check by a certified physicist or biomedical engineer prior to clinical use.
  • ✔ Primis "Integrity-First" Guarantee We guarantee the tube will arrive free of oil leaks and physical housing damage. Due to the sensitive nature of X-ray vacuum inserts, Primis Medical recommends installation by a qualified GE-trained technician to ensure proper calibration and system handshake.
  • (1) GE Proteus MX100 09PS Imaging Tube Assembly (46-155400G46)

Condition

Preowned.

No reviews available.

The Primis TeamProudly Supports

  • DAMIEN HOUSE

    Located in Guayaquil, Ecuador, Damien House exists to provide care and help dispel the stigma of those affected by Hansen's Disease (Leprosy).

  • PROJECT PERFECT WORLD

    Project Perfect World provides orthopedic surgery for children worldwide.

Make an offer
Make an offer
Make an offer