Stryker 5400-099-000 CORE Universal Driver Dual-Trigger Handpiece 5-3/8" Preowned
Stryker 5400-099-000 CORE Universal Driver Dual-Trigger Handpiece 5-3/8" Preowned is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Stryker 5400-099-000 CORE Universal Driver Dual-Trigger Handpiece 5-3/8" Preowned
As part of the CORE (Consolidated Operating Room Equipment) ecosystem, this universal driver delivers a balanced combination of high torque and high speed in a compact, 5-3/8 inch ergonomic chassis.
Technical specifications
- Brand: Stryker
- Reference / model: 5400-099-000
- Model: / REF: 5400-099-000
- Overall Length: 5-3/8 inches
- Power: Source: Electric (CORE / CORE 2 Consoles)
Additional product details
- This handpiece is the industry standard for surgeons who require a lightweight tool that does not sacrifice power for precision.
- Manufacturer: Stryker
- Series: CORE (Consolidated Operating Room Equipment)
- Control: Dual-Trigger (Variable Speed / Directional Control)
- Attachment Interface: Stryker Quick-Connect (Compatible with 5400-series attachments)
- Intelligent Dual-Trigger Ergonomics: The dual-trigger setup allows for instantaneous toggling between modes.
- Multispecialty Versatility: This universal driver is compatible with an extensive library of Stryker attachments, including:
- Wire & Pin Collets (for K-wire fixation)
- AO/Trinkle Drill Chucks
- Keyed/Keyless Jacob’s Chucks
- Sagittal & Reciprocating Saw Attachments
- Orthopedic Trauma: Fixation of small and large fragment fractures.
- Sports Medicine: ACL/PCL reconstruction and joint debridement.
- Podiatry: Osteotomies and fusion procedures of the forefoot and midfoot.
- ENT & Neuro: Cranial flap procedures and skull base surgery.
- Status: Used — Operational Standards Met.
- Maintenance: These handpieces have been clinically used and show visible cosmetic wear consistent with standard hospital sterilization and usage.
- Performance Testing: Each unit has been bench-tested to ensure the motor, triggers, and attachment locking mechanisms meet 2026 operational standards for speed and torque.
- Sterilization Note: This device is provided NON-STERILE. It must be cleaned and sterilized via validated steam autoclave protocols following Stryker’s specific Instructions for Use (IFU) prior to clinical application.
Condition
Preowned.
No reviews available.
The Primis TeamProudly Supports
-
DAMIEN HOUSE
Located in Guayaquil, Ecuador, Damien House exists to provide care and help dispel the stigma of those affected by Hansen's Disease (Leprosy).
-
PROJECT PERFECT WORLD
Project Perfect World provides orthopedic surgery for children worldwide.




